*2024/01/30 15:00:52.21 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : PST 1987/04/07 07:31:00.000 NUMBER OF RECORDS : 12 FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- -------------------- ---------------- -------------- -------------- 1 DEPTH metres 0 600 2 TEMPERATURE 'DEG C (ITS 68)' 8.16 10.1 3 CONDUCTIVITY_RATIO n/a 0.78753 0.89967 4 SALINITY PSS-78 26.798 31.087 5 SIGMA-T n/a 20.54 24.06 6 OXYGEN ml/l 2.87 6.83 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ------ ----- ----- ------ ---- -------------- 1 n/a ' ' 5 F ' ' 0 2 -9.99 ' ' 7 F ' ' 2 3 -99 ' ' 10 F ' ' 5 4 -9.999 ' ' 8 F ' ' 3 5 -9.99 ' ' 7 F ' ' 2 6 -9.99 ' ' 7 F ' ' 2 $END *ADMINISTRATION MISSION : 87-05 AGENCY : UBC SCIENTIST : Soon PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Sn/Geo/Jv STATION : JV 3 EVENT NUMBER : 4 LATITUDE : 49 48.20000 N ! (deg min) LONGITUDE : 124 2.00000 W ! (deg min) WIND : 090.- 8. ! custom item SEA : - M ! custom item AIRDRY : - C ! custom item AIRWET : - C ! custom item SECCHI : - M ! custom item CLOUD : CU 8 ! custom item BAROMETER : 1022 MB ! custom item WANGLE : 0 ! custom item *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- UBC 1.0 1993/06/28 11:48:27 12 12 HDREDIT2 3.2 2024/01/30 15:00:52 ? ? $END $REMARKS -HEADER EDITS: 2024/01/30 15:00:52 Format item moved to details table. Channel 3: CONDUCTIVITY_RATIO [n/a] Format: E15.7 ==> F10.5 Pad: -0.99999 ==> -99 $END *COMMENTS This file converted from UBC's print image file of data reports. Temp: Reversing thermometers or Guildline 8705 CTD probe if tabulated to hundredth of degree Celcius Bucket thermometer (surface) if tabulated to tenths of degree Celcius. Salinity: Guildline Autosal Model 8400 salinometer or Guildline CTD probe Salinities reported in pratical salinity units were estimated from measured conductivity ratios using The Practical Salinity Scale 1978. Conductivity ratio reported is the ratio of conductivity of the sample to that of standard sea water at 20 degrees Celcius. Sigma-t values computed using UNESCO Equation of State of Seawater. Oxygen: The dissolved oxygen content (ml/l) was measured on shipboard by Winkler's method using 50ml samples but modified by using reagents recommended by Carritt, D.E. and Carpenter, J.H., J. Mar. Res. 24;286-318,1966. Meteorological: Cloud amounts expressed in eights and wind speed in knots. !-1-- --2--- ----3---- ---4--- --5--- --6--- !DEPT TEMPER CONDUCTIV SALINIT SIGMA- OXYGEN !H ATURE ITY_RATIO Y T !---- ------ --------- ------- ------ ------ *END OF HEADER 0. 10.10 0.78753 26.798 20.54 -9.99 10. 9.01 0.81039 27.665 21.38 6.83 20. 8.52 0.82100 28.069 21.77 6.16 30. 8.27 0.83406 28.567 22.19 5.82 50. 8.16 0.86625 29.799 23.17 5.09 75. 8.23 0.87189 30.016 23.33 4.94 100. 8.28 0.87487 30.130 23.41 4.85 200. 8.96 0.89082 30.745 23.79 3.17 300. 8.96 0.89854 31.043 24.03 2.91 400. 8.93 0.89912 31.065 24.05 2.87 500. 8.96 0.89954 31.082 24.06 2.87 600. 8.98 0.89967 31.087 24.06 2.87