*2024/11/21 10:40:51.19 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2024/06/01 19:13:00.000 NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Wire + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 19 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Pressure decibar 1.698 1.698 2 Depth metres 1.7 1.7 3 Temperature:Primary 'deg C (ITS90)' 11.1277 11.1277 4 Fluorescence:URU:Wetlabs mg/m^3 1.333 1.333 5 Salinity:T0:C0 PSS-78 29.9664 29.9664 6 PAR uE/m^2/sec 345.7 345.7 7 Oxygen:Dissolved:SBE mL/L 5.41 5.41 8 Oxygen:Dissolved:SBE umol/kg 236.216 236.216 9 Conductivity:Primary S/m 3.405982 3.405982 10 Sample_Number n/a 35 35 11 Nitrate_plus_Nitrite umol/L 13.47 13.47 12 Flag:Nitrate_plus_Nitrite n/a 13 Silicate umol/L 30.2 30.2 14 Flag:Silicate n/a 15 Phosphate umol/L 1.543 1.543 16 Flag:Phosphate n/a 17 Chlorophyll:Extracted mg/m^3 3.7 3.7 18 Flag:Chlorophyll:Extracted n/a 19 Phaeo-Pigment:Extracted mg/m^3 1.59 1.59 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F R4 1 2 -99 ' ' 7 F R4 1 3 -99 ' ' 9 F R4 4 4 -99 ' ' 8 F R4 3 5 -99 ' ' 9 F R4 4 6 -99 ' ' 7 F R4 1 7 -99 ' ' 7 F R4 2 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 10 F R4 5 10 -99 ' ' 5 I I 0 11 -99 ' ' 7 F R4 2 12 ' ' ' ' 3 NQ C ' ' 13 -99 ' ' 7 F R4 2 14 ' ' ' ' 3 NQ C ' ' 15 -99 ' ' 8 F R4 3 16 ' ' ' ' 3 NQ C ' ' 17 -99 ' ' 7 F R4 2 18 ' ' ' ' 3 NQ C ' ' 19 -99 ' ' 7 F R4 2 $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2024-030 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Strait of Georgia Plankton SCIENTIST : Young K. PLATFORM : Neocaligus *LOCATION GEOGRAPHIC AREA : Strait of Georgia STATION : SC-04 EVENT NUMBER : 51 LATITUDE : 48 43.54380 N ! (deg min) LONGITUDE : 123 24.99180 W ! (deg min) WATER DEPTH : 93 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 1255 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SPRD2IS 5.3.1 2024/11/21 10:32:36 1 1 CLEAN 5.3 2024/11/21 10:34:41 1 1 CALIB 12.1 2024/11/21 10:38:33 1 1 CHGUNITS 3.2 2024/11/21 10:39:54 1 1 REORDER 1.3.1 2024/11/21 10:40:16 ? ? REMOVECH 8.2 2024/11/21 10:40:43 1 1 HDREDIT2 3.2 2024/11/21 10:40:51 ? ? $END $REMARKS -CLEAN functions: 2024/11/21 10:34:37 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Delete Empty Channels: 2 deleted. Set header Start and End times from the data. -CALIB parameters: 2024/11/21 10:38:33 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = E:\Telework\2024-030\Processing\doc\2024-030-recal-SIL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 17 Silicate umol/L 120 0.9040000E+00 0.3000000E-02 0.2500000E+02 Salinity:T0:C0 -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -REMOVECH 2024/11/21 10:40:43 The following CHANNEL(S) were removed: Date TIME:UTC -HEADER EDITS: 2024/11/21 10:40:51 Applied edit header: E:\Telework\2024-030\Processing\doc\HYDRO\2024-030-bot-hdr.txt Channel 1: Pressure [decibar] Format: F9.4 ==> F7.1 Channel 9: Conductivity:Primary [S/m] Format: F10.6 ==> F10.5 $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------- -------- ---- ------ ------------ Silicate umol/L 120 -99 (Salinity:T0:C0) (0.904 0.3E-02 25) $END *COMMENTS Analysis methods: ----------------------- Salinity samples were collected in 200 mL type II glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater within 37-41 days after collection. For details, see document QF2024-030SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20C freezer. All samples were returned to the Institute of Ocean Sciences and they were analyzed using an Astoria-Pacific Analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke, J. and F. Whitney. For details see document QF2024-030_NUTS*.xlsx. Chlorophyll samples were filtered onto 25mm GF/F filters after collection, and immediately frozen and stored in a -80C freezer. All samples were returned to the Institute of Ocean Sciences and analyzed 6 weeks after collection on a Turner Trilogy7200-000 fluorometer. Fluorescence readings taken before and after sample acidification were used to calculate chlorophyll and phaeopigment concentrations. For further details on methodology, see document QF 2024-030_CHL_*.xlsx Methodology sheet. NOTE: Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeo-Pigment values. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Nemcek, N. and Peņa, M.A. 2014. Institute of Ocean Sciences Protocols for Phytoplankton Pigment Analysis by HPLC. Can. Tech. Rep. Fish. Aquat. Sci. 3117: x + 80 p. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers ---------------------------------------------------------------------------------------------------- CTD Data Processing Notes: ---------------------- NOTE: The CTD data in these files were extracted from CTD casts and are not from exactly the same time or depth as the samples. The data are provided only as a rough guide to ambient conditions. Oxygen:Dissolved, Conductivity, PAR and Fluorescence:URU:Wetlabs data are nominal and unedited except that some records were removed in editing temperature and salinity. There were only 6 salinity calibration samples taken during this cruise, of which only 3 were below 5m, of which 1 was collected an hour later than the CTD cast with which it was compared. The CTD data were lower than the 2 useful bottle samples by about 0.001psu; the CTD may be reading low by a little more than that suggests due to incomplete flushing of NIskin bottles. Salinity is likely good to +/-0.005psu. 8 extracted chlorophyll samples were gathered at the surface using a bucket, and 3 samples came from a Niskin bottle at 5m. CTD data for comparison were drawn from between 1.1db and 2.1db. The ratio of CTD Fluorescence to Extracted CHL samples was somewhat lower than usually seen, but this may be due to the sampling being so shallow. The ratio dropped with increasing CHL, as is usually seen from these sensors. Oxygen:Dissolved:SBE values cannot be confirmed as there was no calibration sampling for dissolved oxygen. Surface saturation values were between 70% and 110% with all values below 80% coming from near the Gulf Islands where strong vertical mixing is likely to be strong. Dissolved oxygen data from these sensors tend to be low by between 1% and 3%. For details on the processing see document: 2024-030_Processing_Report.doc. !--1--- --2--- ---3---- ---4--- ---5---- --6--- --7--- --8-- ----9---- -10- --11-- 12 --13-- 14 ---15-- 16 --17-- 18 --19-- !Pressu Depth Temperat Fluores Salinity PAR Oxygen Oxyge Conductiv Samp Nitrat Fl Silica Fl Phospha Fl Chloro Fl Phaeo- !re ure: cence: :T0:C0 : n: ity: le_ e_ ag te ag te ag phyll: ag Pigmen ! Primary URU: Dissol Disso Primary Numb plus_ ~t ~i ~p Extrac ~a t: ! Wetlabs ved: lved: er Nitrit ri ca ha ted ct Extrac ! SBE SBE e te te te ed ted !------ ------ -------- ------- -------- ------ ------ ----- --------- ---- ------ -- ------ -- ------- -- ------ -- ------ *END OF HEADER 1.7 1.7 11.1277 1.333 29.9664 345.7 5.41 236.2 3.40598 35 13.47 6 30.20 6 1.543 6 3.70 0 1.59