*2024/04/22 16:29:06.61 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2023/08/15 06:36:06.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 24 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 98DF0F98 NUMBER OF CHANNELS : 26 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 24 2 Bottle:Firing_Sequence n/a 1 24 3 Pressure decibar 5.562 3685.637 4 Depth metres 5.515 3622.75 5 Temperature:Primary 'deg C (ITS90)' 1.5724 17.4739 6 Transmissivity %/metre 50.4 70.9 7 Transmissivity:Green %/metre 67.5 100.7 8 Fluorescence:URU:Seapoint mg/m^3 0.73E-01 2.519 9 Salinity:T0:C0 PSS-78 32.158 34.6646 10 Oxygen:Dissolved:SBE mL/L 0.268 7.169 11 Oxygen:Dissolved:SBE umol/kg 11.7 312.6 12 Conductivity:Primary S/m 3.126364 4.206418 13 Number_of_bin_records n/a 241 241 14 Sample_Number n/a 272 295 15 Temperature:Draw 'deg C (ITS90)' 5.2 18.6 16 Salinity:Bottle PSS-78 34.2881 34.6628 17 Flag:Salinity:Bottle n/a 18 Oxygen:Dissolved mL/L 0.26 7.075 19 Oxygen:Dissolved umol/kg 11.30658 308.5807 20 Flag:Oxygen:Dissolved n/a 21 Nitrate_plus_Nitrite umol/L 0.58 47.2 22 Flag:Nitrate_plus_Nitrite n/a 23 Silicate umol/L 1.96 180.56 24 Flag:Silicate n/a 25 Phosphate umol/L 0.439 3.309 26 Flag:Phosphate n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' 9 F ' ' 4 10 -99 ' ' 7 F ' ' 2 11 -99 ' ' 6 F ' ' 1 12 -99 ' ' 10 F ' ' 5 13 -99 ' ' 5 I I 0 14 -99 ' ' 5 I I 0 15 -99 ' ' 6 F R4 1 16 -99 ' ' 9 F R4 4 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 8 F R4 3 19 -99 ' ' 6 F ' ' 1 20 n/a ' ' 3 NQ C ' ' 21 -99 ' ' 7 F R4 2 22 0 ' ' 3 NQ C ' ' 23 -99 ' ' 7 F R4 2 24 0 ' ' 3 NQ C ' ' 25 -99 ' ' 8 F R4 3 26 0 ' ' 3 NQ C ' ' $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2023-088 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P16 EVENT NUMBER : 47 LATITUDE : 49 17.02000 N ! (deg min) LONGITUDE : 134 39.98000 W ! (deg min) WATER DEPTH : 3615 ALTIMETER (M) : 10.79 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 1515 LOCATION : Mid-ship ! custom item $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 6754 Conductivity ' ' 6141 'Pressure:Digiquartz with TC' ' ' 1515 Temperature:2 ' ' 6736 Conductivity:2 ' ' 6146 'Oxygen:SBE 43' ' ' 1119 Fluorometer:Seapoint ' ' 3950 PAR/Irradiance:Biospherical/Licor ' ' 70613 Altimeter ' ' 79487 'Transmissometer:WET Labs C-Star' ' ' 1185DR 'Transmissometer:WET Labs C-Star:2' ' ' 1883DG $END $REMARKS Software Version Seasave V 7.26.7.121 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.3 2024/01/31 13:38:26 5784 5784 CLEAN 5.3 2024/01/31 13:38:48 5784 5784 ADDSAMP 3.6 2024/02/09 08:31:14 5784 5784 BINAVE 4.2.1 2024/02/09 08:32:31 5784 24 MERGE 3.6 2024/03/25 16:19:40 24 24 MERGE 3.6 2024/03/25 16:20:39 24 24 CLEAN 5.3 2024/03/25 16:24:37 24 24 CALIB 12.1 2024/03/25 16:33:21 24 24 SORT 3.6 2024/04/08 15:25:04 24 24 REMOVECH 8.2 2024/04/08 15:43:38 24 24 CHGUNITS 3.2 2024/04/08 15:44:28 24 24 CHGUNITS 3.2 2024/04/08 15:44:31 24 24 REORDER 1.3.1 2024/04/08 16:25:10 ? ? HDREDIT2 3.2 2024/04/22 16:29:06 ? ? $END $REMARKS -CLEAN functions: 2024/01/31 13:38:42 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: E:\Telework\2023-088\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2024/03/25 16:19:40 Merge Channel: Bottle_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Sample_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Dimethyl_Sulphide_7890GC, Flag:Dimethyl_Sulphide_7890GC, Dimethyl_Sulphide_8890GC, Flag:Dimethyl_Sulphide_8890GC, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolved, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total, Ammonium, Flag:Ammonium, Event Primary file : E:\Telework\2023-088\Processing\hydro\2023-088-0047.samavg Secondary file: E:\Telework\2023-088\Processing\hydro\2023-088-0047.event 24 secondary records matched to primary records. -The following MERGE parameters were used: 2024/03/25 16:20:39 Merge Channel: Bottle_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Sample_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Dimethyl_Sulphide_7890GC, Flag:Dimethyl_Sulphide_7890GC, Dimethyl_Sulphide_8890GC, Flag:Dimethyl_Sulphide_8890GC, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolved, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total, Ammonium, Flag:Ammonium Primary file : E:\Telework\2023-088\Processing\hydro\2023-088-0047.samevt Secondary file: E:\Telework\2023-088\Processing\hydro\2023-088-0047.mrgcln1s 24 secondary records matched to primary records. -CLEAN functions: 2024/03/22 13:56:02 20 Reduce header to sections: FIL HIS COM Remarks removed from kept sections. Reset #RECS, MIN & MAX values in header. -SORT parameters: 2024/03/22 13:56:08 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2024/03/25 16:24:31 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2024/03/25 16:33:21 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = E:\Telework\2023-088\Processing\doc\2023-088-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 18 Salinity:T0:C0 PSS-78 11 0.2400000E-02 0.3000000E-04 Event 19 Salinity:T1:C1 PSS-78 11 0.9000000E-03 0.8000000E-04 Event 20 Oxygen:Dissolved:SBE mL/L 10 0.2500000E-01 0.1016500E+01 -SORT parameters: 2024/04/08 15:25:04 Sorted in ascending order of channel Pressure [decibar] -REMOVECH 2024/04/08 15:43:38 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] PAR [umol/m^2/sec] Descent_Rate [m/s] Status:Pump Altimeter [metres] Salinity:T1:C1 [PSS-78] Flag Event -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw [deg C (ITS90)] Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved' changed from mL/L to umol/kg -HEADER EDITS: 2024/04/22 16:29:06 Applied edit header: E:\Telework\2023-088\Processing\doc\HYDRO\2023-088-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F10.3 ==> F7.1 Channel 4: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 6: Transmissivity [%/metre] Name: Transmissivity:1 ==> Transmissivity Channel 7: Transmissivity:Green [%/metre] Name: Transmissivity:2 ==> Transmissivity:Green Channel 10: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 13: Number_of_bin_records [n/a] Pad: ' ' ==> -99 Channel 15: Temperature:Draw [deg C (ITS90)] Format: F7.2 ==> F6.1 Channel 17: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 20: Flag:Oxygen:Dissolved [n/a] Units: ==> n/a Pad: 0 ==> n/a Channel 22: Flag:Nitrate_plus_Nitrite [n/a] Units: ==> n/a Channel 24: Flag:Silicate [n/a] Units: ==> n/a Channel 26: Flag:Phosphate [n/a] Units: ==> n/a Channel 12: Conductivity:Primary [S/m] Format: F11.6 ==> F10.5 $END *COMMENTS Sample_Number 275: OXY: Sample over-titrated as a result of a late endpoint. Sample_Number 286: OXY-2: Sample over-titrated as a result of a late endpoint. Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and immediately frozen and stored in a -80C freezer until analysis. All samples were returned to the Institute of Ocean Sciences and analyzed 10-11 weeks after the cruise on a Turner Trilogy 7200-000 fluorometer, using methods described in Holm-Hansen et al (1965). Fluorescence readings taken before and after sample acidification were used to calculate chlorophyll and phaeopigment concentrations. For details see worksheet “CV%” in file QF2023-088_CHL*.xlsx. NOTE: Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeo-Pigment values. Oxygen samples were analyzed at sea using an automated Winkler titration System (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a precision analysis, see document QF2023-088OXY*.xlsx. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater 13 - 26 days after collection. For details including a duplicate analysis, see document QF2023-088SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20C freezer. For samples 400m and deeper a second set of samples are collected and stored cool for silicate analysis. All samples were returned to the Institute of Ocean Sciences and they were analyzed using an Astoria-Pacific Analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2023-088nuts*.xlsx. The minimum detectable level for DMS is 0.1 nM, so “0” values should be interpreted as <0.1 nM. DMS data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. All stations were run on two separate systems: an older 7890 DMS System in use since 2013 and a new system with a 8890 gas chromatograph which was being used for the first time for systems comparison. Results from both systems are presented. For more details on analysis and comparison of the two systems see document "QF2023-088_DMS*.xlsx". The minimum detectable level for DMSP is 0.1 nM, so “0” values should be interpreted as <0.1 nM. DMSP data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. For more details including method, raw data and duplicates, see document "QF2023-088_DMSP.xls”. A report on DMS and DMSP is in document 2023-088 DMS report*.doc. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Conductivity, Transmissivity, Fluorescence and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. NOTE: While the SBE fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. There were 2 WetLabs CStar transmissometers in use during this cruise: Channel Transmissometer refers to sensor #1185DR (650nm - red) Channel Transmissometer:Green refers to sensor #1883DG (530nm - green) For comparison with other Institute of Ocean Sciences cruises, note that the transmissometer wavelength is 650nm unless otherwise stated. For details on the processing see the report: 2023-088_Processing_Report.doc. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 11 -99 (Event) (0.24E-02 0.3E-04) Salinity:T1:C1 PSS-78 11 -99 (Event) (0.9E-03 0.8E-04) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.25E-01 1.0165) $END !1- 2- --3--- --4--- ---5---- --6-- --7-- ---8--- ---9---- --10-- --11- ----12--- -13- -14- --15- ---16--- 17 ---18-- --19- 20 --21-- 22 --23-- 24 ---25-- 26 !Bo Bo Pressu Depth Temperat Trans Trans Fluores Salinity Oxygen Oxyge Conductiv Numb Samp Tempe Salinity Fl Oxygen: Oxyge Fl Nitrat Fl Silica Fl Phospha Fl !tt tt re ure: missi missi cence: :T0:C0 : n: ity: er_o le_ ratur :Bottle ag Dissolv n: ag e_ ag te ag te ag !~u ~u Primary vity vity: URU: Dissol Disso Primary ~bin Numb e: ~o ed Disso ~o plus_ ~t ~i ~p !mb en Green Seapoin ved: lved: _rec er Draw tt lved lv Nitrit ri ca ha !er ce t SBE SBE ords le ed e te te te !-- -- ------ ------ -------- ----- ----- ------- -------- ------ ----- --------- ---- ---- ----- -------- -- ------- ----- -- ------ -- ------ -- ------- -- *END OF HEADER 23 23 5.6 5.5 17.4739 50.4 67.6 2.518 32.1611 5.97 260.4 4.20642 241 294 18.6 -99.0000 0 5.946 259.6 0 0.58 0 1.96 0 0.439 0 24 24 5.6 5.5 17.4706 50.4 67.5 2.519 32.1614 5.96 260.3 4.20614 241 295 -99.0 -99.0000 0 -99.000 -99.0 0 -99.00 0 -99.00 0 -99.000 0 22 22 10.0 9.9 17.2945 53.0 71.2 2.320 32.1580 5.96 260.0 4.18958 241 293 18.5 -99.0000 0 5.941 259.4 0 0.66 0 2.04 0 0.448 0 21 21 25.4 25.2 12.8074 65.7 91.0 0.638 32.3400 7.17 312.6 3.79945 241 292 14.9 -99.0000 0 7.075 308.6 6 3.47 0 4.34 0 0.660 0 20 20 50.3 49.9 7.5432 64.3 89.1 1.398 32.3609 6.89 300.3 3.33666 241 291 10.5 -99.0000 0 6.828 297.6 0 9.46 0 10.98 0 1.077 0 19 19 75.1 74.4 7.1841 67.9 95.3 0.551 32.3960 6.76 294.6 3.30991 241 290 10.3 -99.0000 0 6.704 292.1 0 10.87 0 12.39 0 1.137 0 18 18 100.9 100.0 6.8370 69.1 97.6 0.230 32.6326 6.04 262.9 3.30269 241 289 10.0 -99.0000 0 6.056 263.8 0 15.88 0 18.82 0 1.380 0 17 17 125.0 123.9 6.8707 69.5 98.1 0.128 33.3095 3.98 173.3 3.36843 241 288 9.9 -99.0000 0 4.020 175.0 0 26.44 0 34.30 0 1.977 0 16 16 150.0 148.7 6.8483 69.8 98.7 0.102 33.6367 3.13 136.1 3.39733 241 287 9.9 -99.0000 0 3.130 136.3 0 30.58 0 41.99 0 2.213 0 15 15 175.5 174.0 6.6581 69.9 98.8 0.090 33.7770 2.75 119.6 3.39424 241 286 9.8 -99.0000 0 2.735 119.0 26 32.30 6 47.09 6 2.342 6 14 14 201.1 199.2 6.3656 69.9 98.8 0.087 33.8265 2.53 110.2 3.37377 241 285 9.4 -99.0000 0 2.516 109.5 0 33.96 0 51.42 0 2.390 0 13 13 250.5 248.2 5.7266 70.0 98.9 0.086 33.8903 1.95 84.9 3.32486 241 284 8.8 -99.0000 0 1.978 86.1 0 37.54 0 61.95 0 2.640 0 12 12 300.7 298.0 4.8612 70.1 99.1 0.088 33.8625 1.80 78.3 3.24826 241 283 8.0 -99.0000 0 1.811 78.8 0 40.01 0 71.78 0 2.773 0 11 11 400.7 396.9 4.6157 70.5 99.7 0.088 33.9945 1.05 45.6 3.24248 241 282 7.8 -99.0000 0 1.050 45.7 0 43.29 0 86.81 0 3.032 0 10 10 600.4 594.5 4.1163 70.6 100.0 0.089 34.1620 0.44 19.3 3.22165 241 281 7.4 -99.0000 0 0.441 19.2 0 45.72 0 108.95 0 3.214 0 9 9 800.2 791.9 3.6373 70.6 99.9 0.089 34.2872 0.27 11.9 3.19885 241 280 7.3 34.2881 0 0.270 11.7 6 46.84 0 127.34 0 3.309 0 8 8 1000.5 989.6 3.2016 70.6 100.0 0.088 34.3699 0.27 11.7 3.17620 241 279 6.6 34.3703 0 0.260 11.3 0 47.19 0 141.59 0 3.300 0 7 7 1250.5 1236.2 2.7095 70.6 100.0 0.087 34.4423 0.36 15.6 3.14982 241 278 6.4 34.4431 0 0.345 15.0 0 47.20 0 157.08 0 3.260 0 6 6 1499.3 1481.2 2.3599 70.7 100.2 0.085 34.5012 0.58 25.2 3.13459 241 277 6.1 34.5009 0 0.572 24.9 0 46.77 0 167.08 0 3.209 0 5 5 2001.2 1974.7 1.9534 70.8 100.5 0.078 34.5826 1.28 55.6 3.12636 241 276 5.9 34.5838 6 1.275 55.4 0 44.82 0 176.31 0 3.058 0 4 4 2499.6 2463.7 1.7430 70.9 100.7 0.075 34.6239 1.86 81.0 3.13111 241 275 5.5 34.6243 0 1.863 81.0 2 42.66 6 178.80 6 2.989 6 3 3 3001.1 2954.5 1.6076 70.8 100.7 0.073 34.6500 2.39 103.9 3.14055 241 274 5.6 34.6516 0 2.392 104.0 6 41.55 0 178.01 0 2.828 0 2 2 3500.1 3441.9 1.5724 70.6 100.4 0.073 34.6623 2.66 115.5 3.15678 241 273 5.3 34.6628 6 2.670 116.1 0 40.82 0 179.57 0 2.787 0 1 1 3685.6 3622.8 1.5771 70.2 99.9 0.073 34.6646 2.70 117.4 3.16398 241 272 5.2 -99.0000 0 2.717 118.1 0 40.60 0 180.56 0 2.776 0