*2023/11/03 13:18:32.19 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2023/05/09 08:20:30.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 24 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 761E0EAD NUMBER OF CHANNELS : 15 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 24 2 Bottle:Firing_Sequence n/a 1 24 3 Pressure decibar 24.89 101.73 4 Depth metres 24.678 100.841 5 Temperature:Primary 'deg C (ITS90)' 5.9122 7.1574 6 Transmissivity %/metre 60.1 68.7 7 Transmissivity:Green %/metre 79.9 94.8 8 Fluorescence:URU:Seapoint mg/m^3 0.303 1.559 9 PAR uE/m^2/sec 0 0 10 Salinity:T0:C0 PSS-78 32.3679 32.5612 11 Oxygen:Dissolved:SBE mL/L 6.736 7.208 12 Oxygen:Dissolved:SBE umol/kg 293.3 314 13 Conductivity:Primary S/m 3.216784 3.303162 14 Number_of_bin_records n/a 31 241 15 Sample_Number n/a 569 592 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' 7 F ' ' 1 10 -99 ' ' 9 F ' ' 4 11 -99 ' ' 7 F ' ' 2 12 -99 ' ' 6 F ' ' 1 13 -99 ' ' 10 F ' ' 5 14 -99 ' ' 5 I I 0 15 -99 ' ' 5 I I 0 $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2023-066 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P26 EVENT NUMBER : 84 LATITUDE : 49 59.96000 N ! (deg min) LONGITUDE : 145 0.04000 W ! (deg min) WATER DEPTH : 4222 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 LOCATION : Mid-ship ! custom item $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 2663 Conductivity ' ' 2280 'Pressure:Digiquartz with TC' ' ' 0550 Temperature:2 ' ' 2106 Conductivity:2 ' ' 2754 Fluorometer:Seapoint ' ' 3640 'Oxygen:SBE 43' ' ' 3791 PAR/Irradiance:Biospherical/Licor ' ' 70613 Altimeter ' ' ' ' 'Transmissometer:WET Labs C-Star' ' ' 1185DR 'Transmissometer:WET Labs C-Star:2' ' ' 1883DG $END $REMARKS Software Version Seasave V 7.26.7.121 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.3 2023/09/07 10:19:16 1741 1741 CLEAN 5.3 2023/09/07 10:24:15 1741 1741 CTDEDIT 5.4.0 2023/09/07 10:38:07 1741 1741 ADDSAMP 3.6 2023/09/07 10:42:10 1741 1741 BINAVE 4.2.1 2023/09/07 10:42:30 1741 24 MERGE 3.6 2023/11/03 10:02:43 24 24 CLEAN 5.3 2023/11/03 10:02:48 24 24 CALIB 12.1 2023/11/03 10:03:57 24 24 CALIB 12.1 2023/11/03 10:04:11 24 24 SORT 3.6 2023/11/03 10:04:21 24 24 REMOVECH 8.2 2023/11/03 10:04:35 24 24 CHGUNITS 3.2 2023/11/03 10:04:45 24 24 CHGUNITS 3.2 2023/11/03 10:04:57 24 24 REORDER 1.3.1 2023/11/03 10:05:14 ? ? HDREDIT2 3.2 2023/11/03 13:18:32 ? ? $END $REMARKS -CLEAN functions: 2023/09/07 10:24:11 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -CTDEDIT v5.4.0 2023/09/07 10:38:07 9 changes in channel Salinity:T1:C1 1741 changes in channel Pressure -The following ADDSAMP parameters were used: Sample Number Lookup File: D:\Telework\2023-066\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2023/11/03 10:02:43 Merge Channel: Bottle_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Sample_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolved, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total Primary file : E:\Telework\2023-066\Processing\hydro\2023-066-0084.samavg Secondary file: E:\Telework\2023-066\Processing\hydro\2023-066-0084.mrgcln1s 24 secondary records matched to primary records. Comments from secondary file: E:\Telework\2023-066\Processing\hydro\2023-066-0084.mrgcln1s ------------------------------------------------------------ -CLEAN functions: 2023/11/03 10:01:56 20 Reduce header to sections: FIL HIS COM Remarks removed from kept sections. Reset #RECS, MIN & MAX values in header. -SORT parameters: 2023/11/03 10:02:11 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2023/11/03 10:02:46 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name Remove Sea-Bird comments from the header. -CALIB parameters: 2023/11/03 10:03:57 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = E:\Telework\2023-066\Processing\doc\2023-066-recal-SIL.CCF WARNING: No calibration done on file E:\Telework\2023-066\Processing\hydro\2023-066-0084.mrgcorsil -CALIB parameters: 2023/11/03 10:04:11 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = E:\Telework\2023-066\Processing\doc\2023-066-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 4 Pressure decibar 10 0.8000000E+00 0.1000000E+01 5 Depth:Salt_Water metres 10 0.8000000E+00 0.1000000E+01 20 Oxygen:Dissolved:SBE mL/L 10 -0.9400000E-02 0.1011500E+01 -SORT parameters: 2023/11/03 10:04:21 Sorted in ascending order of channel Pressure [decibar] -REMOVECH 2023/11/03 10:04:35 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Descent_Rate [m/s] Status:Pump Altimeter [metres] Salinity:T1:C1 [PSS-78] Flag -CHANGE units: Temperature reference channel: Temperature:Primary [deg C (ITS90)] Salinity reference channel: Salinity:T0:C0 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T0:C0 - No units changed -HEADER EDITS: 2023/11/03 13:18:32 Applied edit header: E:\Telework\2023-066\Processing\doc\HYDRO\2023-066-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F11.2 ==> F7.1 Channel 4: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 6: Transmissivity [%/metre] Name: Transmissivity:1 ==> Transmissivity Channel 7: Transmissivity:Green [%/metre] Name: Transmissivity:2 ==> Transmissivity:Green Channel 11: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 14: Number_of_bin_records [n/a] Pad: ' ' ==> -99 Channel 9: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 13: Conductivity:Primary [S/m] Format: F11.6 ==> F10.5 $END *COMMENTS Remarks from CTDEDIT: CTDEDIT was used to clean a few spikes in the secondary salinity channel. Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and immediately frozen and stored in a -80C freezer until analysis. All samples were returned to the Institute of Ocean Sciences and analyzed 2.5 weeks after the cruise on a Turner Trilogy 7200-000 fluorometer, using methods described in Holm-Hansen et al (1965). Fluorescence readings taken before and after sample acidification were used to calculate chlorophyll and phaeopigment concentrations. For details see worksheet “CV%” in file QF2023-066_CHL*.xlsx. NOTE: Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeo-Pigment values. Oxygen samples were analyzed at sea using an automated Winkler titration System (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2023-066OXY*.xlsx. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater 18 - 34 days after collection. For details including a duplicate analysis, see document QF2023-066SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20C freezer. For samples 400m and deeper a second set of samples are collected and stored cool for silicate analysis. All samples were returned to the Institute of Ocean Sciences and they were analyzed using an Astoria-Pacific Analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2023-066nuts*.xlsx. The minimum detectable level for DMS is 0.1 nM, so “0” values should be interpreted as <0.1 nM. DMS data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. For more details including method, raw data and duplicates, see document "DMS Summary (2023-066).xls”. Detailed notes on analysis are in file 2023-066 DMS report*.doc. 7890 DMS System was used for all stations except P26 for which the new 8890 System was used. The minimum detectable level for DMSP is 0.1 nM, so “0” values should be interpreted as <0.1 nM. DMSP data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. For more details including method, raw data and duplicates, see document "DMSP 2023-066 Summary*.xls”. Detailed notes on analysis are in file 2023-066 DMS report*.doc. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Conductivity, Transmissivity, Fluorescence and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. Two CTDs were used for this cruise (Events #1-58 and #60-153). The CTD data were affected by frequent pressure spikes that were not resolved by replacing the CTD with a new one. Most large spikes were below 1000db and were removed in processing. None were noted during stops for bottles. For Events #1-39 the configuration file was set as follows: Number of Scans Averaged by the Deck Unit = 24 Normally each scan is recorded individually and averaging is not done until after fine-tuning of settings for alignment and removal of bad records. The quality of CTD data from casts #1-39 is considered lower than usual. Fluorescence data were removed from Events #26-39 due to fluorometer malfunction. A new fluorometer was installed for Events #41-153. NOTE: While the SBE fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. There were 2 WetLabs CStar transmissometers in use during this cruise: Channel Transmissometer refers to sensor #1185DR (650nm - red) Channel Transmissometer:Green refers to sensor #1883DG (530nm - green) For comparison with other Institute of Ocean Sciences cruises, note that the transmissometer wavelength is 650nm unless otherwise stated. For details on the processing see the report: 2023-066_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- --------- ---- ------ ------------ Pressure decibar 10 -99 () (0.8 1) Depth:Salt_Water metres 10 -99 () (0.8 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (-0.94E-02 1.0115) $END !1- 2- --3--- --4--- ---5---- --6-- --7-- ---8--- --9--- ---10--- --11-- --12- ----13--- -14- -15- !Bo Bo Pressu Depth Temperat Trans Trans Fluores PAR Salinity Oxygen Oxyge Conductiv Numb Samp !tt tt re ure: missi missi cence: :T0:C0 : n: ity: er_o le_ !~u ~u Primary vity vity: URU: Dissol Disso Primary ~bin Numb !mb en Green Seapoin ved: lved: _rec er !er ce t SBE SBE ords !-- -- ------ ------ -------- ----- ----- ------- ------ -------- ------ ----- --------- ---- ---- *END OF HEADER 22 22 24.9 24.7 7.1574 60.4 79.9 1.423 0.0 32.3679 7.21 314.0 3.30316 64 590 24 24 25.2 25.0 7.1498 60.1 80.1 1.427 0.0 32.3684 7.19 313.3 3.30257 241 592 23 23 25.4 25.1 7.1559 60.3 79.9 1.396 0.0 32.3681 7.19 313.1 3.30307 40 591 18 18 39.5 39.1 6.6084 62.2 83.6 1.509 0.0 32.4124 7.16 311.9 3.26055 37 586 13 13 39.6 39.3 6.5965 62.1 83.6 1.539 0.0 32.4141 7.10 309.2 3.25969 33 581 19 19 39.7 39.4 6.6012 62.3 83.8 1.559 0.0 32.4133 7.14 310.9 3.26003 34 587 17 17 40.0 39.7 6.6089 62.2 83.8 1.527 0.0 32.4124 7.10 309.1 3.26062 31 585 20 20 40.2 39.9 6.5942 62.8 84.7 1.534 0.0 32.4144 7.10 309.4 3.25955 33 588 21 21 40.3 40.0 6.6002 62.5 84.4 1.547 0.0 32.4141 7.13 310.5 3.26004 241 589 14 14 40.4 40.1 6.5803 62.6 84.1 1.545 0.0 32.4152 7.13 310.5 3.25843 33 582 16 16 40.8 40.4 6.6076 62.6 84.5 1.520 0.0 32.4127 7.12 310.1 3.26057 31 584 15 15 41.0 40.6 6.5844 62.6 84.3 1.513 0.0 32.4161 7.11 309.8 3.25890 31 583 10 10 59.1 58.6 6.2101 65.5 89.4 1.121 0.0 32.4308 7.06 307.6 3.22886 31 578 9 9 59.3 58.8 6.2107 65.6 89.2 1.138 0.0 32.4305 7.07 307.7 3.22890 32 577 4 4 59.4 58.9 6.2079 65.6 89.3 1.108 0.0 32.4307 7.07 307.9 3.22868 34 572 12 12 60.2 59.7 6.2098 65.6 89.4 1.126 0.0 32.4306 7.07 307.8 3.22887 241 580 8 8 60.2 59.7 6.2103 65.6 89.2 1.114 0.0 32.4306 7.07 307.8 3.22891 32 576 5 5 60.4 59.9 6.2056 65.7 89.5 1.130 0.0 32.4307 7.09 308.6 3.22852 33 573 11 11 60.6 60.1 6.2081 65.7 89.3 1.136 0.0 32.4307 7.08 308.2 3.22875 70 579 7 7 61.2 60.6 6.2074 65.7 89.5 1.103 0.0 32.4306 7.06 307.5 3.22871 34 575 6 6 61.3 60.8 6.2054 65.6 89.3 1.110 0.0 32.4308 7.07 307.8 3.22856 31 574 1 1 101.1 100.2 5.9138 68.7 94.7 0.303 0.0 32.5594 6.75 293.8 3.21678 48 569 3 3 101.2 100.3 5.9233 68.7 94.7 0.305 0.0 32.5557 6.74 293.7 3.21728 241 571 2 2 101.7 100.8 5.9122 68.7 94.8 0.307 0.0 32.5612 6.74 293.3 3.21684 65 570