*2024/05/02 13:10:05.24 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2023/08/28 07:32:25.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 21 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 80CF6459 NUMBER OF CHANNELS : 32 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 21 2 Bottle:Firing_Sequence n/a 1 21 3 Pressure decibar 4.684 1597.972 4 Depth metres 4.645 1578.445 5 Temperature:Primary 'deg C (ITS90)' 2.4391 15.7675 6 Transmissivity %/metre 44.8 70.2 7 Transmissivity:Green %/metre 57.2 99.7 8 Fluorescence:URU:Seapoint mg/m^3 0.88E-01 3.604 9 PAR uE/m^2/sec 0 0.181 10 Salinity:T0:C0 PSS-78 32.2697 34.5269 11 Oxygen:Dissolved:SBE mL/L 0.209 6.787 12 Oxygen:Dissolved:SBE umol/kg 9.1 295.9 13 Conductivity:Primary S/m 3.147546 4.060837 14 Number_of_bin_records n/a 71 241 15 Sample_Number n/a 196 216 16 Temperature:Draw 'deg C (ITS90)' 6 17.3 17 Salinity:Bottle PSS-78 32.2701 34.499 18 Flag:Salinity:Bottle n/a 19 Chlorophyll:Extracted mg/m^3 0.31 2.01 20 Flag:Chlorophyll:Extracted n/a 21 Phaeo-Pigment:Extracted mg/m^3 0.24 0.81 22 Oxygen:Dissolved mL/L 0.222 6.657 23 Oxygen:Dissolved umol/kg 9.65469 290.348 24 Flag:Oxygen:Dissolved n/a 25 Nitrate_plus_Nitrite umol/L 0.1 45.08 26 Flag:Nitrate_plus_Nitrite n/a 27 Silicate umol/L 4 166.62 28 Flag:Silicate n/a 29 Phosphate umol/L 0.367 3.316 30 Flag:Phosphate n/a 31 Ammonium umol/L 0.21 0.39 32 Flag:Ammonium ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' 7 F ' ' 1 10 -99 ' ' 9 F ' ' 4 11 -99 ' ' 7 F ' ' 2 12 -99 ' ' 6 F ' ' 1 13 -99 ' ' 10 F ' ' 5 14 -99 ' ' 5 I I 0 15 -99 ' ' 5 I I 0 16 -99 ' ' 6 F R4 1 17 -99 ' ' 9 F R4 4 18 0 ' ' 3 NQ C ' ' 19 -99 ' ' 7 F R4 2 20 0 ' ' 3 NQ C ' ' 21 -99 ' ' 7 F R4 2 22 -99 ' ' 8 F R4 3 23 -99 ' ' 6 F ' ' 1 24 n/a ' ' 3 NQ C ' ' 25 -99 ' ' 7 F R4 2 26 0 ' ' 3 NQ C ' ' 27 -99 ' ' 7 F R4 2 28 0 ' ' 3 NQ C ' ' 29 -99 ' ' 8 F R4 3 30 0 ' ' 3 NQ C ' ' 31 -99 ' ' ' ' F7.2 R4 ' ' 32 0 ' ' 3 NQ C ' ' $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2023-026 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : La Perouse SCIENTIST : Sastri A. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI STATION : LD11 EVENT NUMBER : 71 LATITUDE : 48 28.77000 N ! (deg min) LONGITUDE : 126 42.97000 W ! (deg min) WATER DEPTH : 1595 ALTIMETER (M) : 9.3 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 LOCATION : Mid-ship ! custom item $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 6754 Conductivity ' ' 6141 'Pressure:Digiquartz with TC' ' ' 1515 Temperature:2 ' ' 6736 Conductivity:2 ' ' 6146 'Oxygen:SBE 43' ' ' 1119 Fluorometer:Seapoint ' ' 3950 PAR/Irradiance:Biospherical/Licor ' ' 70613 Altimeter ' ' 79487 'Transmissometer:WET Labs C-Star' ' ' 1185DR 'Transmissometer:WET Labs C-Star:2' ' ' 1883DG $END $REMARKS Software Version Seasave V 7.26.7.121 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.3 2024/04/16 14:54:27 4891 4891 CLEAN 5.3 2024/04/16 14:54:44 4891 4891 ADDSAMP 3.6 2024/04/16 15:57:04 4891 4891 BINAVE 4.2.1 2024/04/16 16:11:45 4891 21 MERGE 3.6 2024/04/17 12:50:52 21 21 CLEAN 5.3 2024/04/17 12:51:01 21 21 CALIB 12.1 2024/05/01 15:00:16 21 21 SORT 3.6 2024/05/01 16:54:18 21 21 REMOVECH 8.2 2024/05/01 16:55:13 21 21 CHGUNITS 3.2 2024/05/01 16:56:16 21 21 CHGUNITS 3.2 2024/05/01 16:56:19 21 21 REORDER 1.3.1 2024/05/01 16:57:09 ? ? HDREDIT2 3.2 2024/05/02 13:10:05 ? ? $END $REMARKS -CLEAN functions: 2024/04/16 14:54:39 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: E:\Telework\2023-026\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2024/04/17 12:50:52 Merge Channel: Bottle_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Sample_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Dimethyl_Sulphide_7890GC, Flag:Dimethyl_Sulphide_7890GC, Dimethyl_Sulphide_8890GC, Flag:Dimethyl_Sulphide_8890GC, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolved, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total, Ammonium, Flag:Ammonium Primary file : E:\Telework\2023-026\Processing\hydro\2023-026-0071.samavg Secondary file: E:\Telework\2023-026\Processing\hydro\2023-026-0071.mrgcln1s 21 secondary records matched to primary records. -CLEAN functions: 2024/04/17 12:50:29 20 Reduce header to sections: FIL ADM LOC DEP REC INS HIS RAW CAL COM Remarks removed from kept sections. -SORT parameters: 2024/04/17 12:50:36 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2024/04/17 12:50:59 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2024/05/01 15:00:16 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = E:\Telework\2023-026\Processing\doc\2023-026-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 18 Salinity:T0:C0 PSS-78 10 0.5300000E-02 0.1000000E+01 19 Salinity:T1:C1 PSS-78 10 0.6300000E-02 0.1000000E+01 20 Oxygen:Dissolved:SBE mL/L 10 0.1130000E-01 0.1022700E+01 -SORT parameters: 2024/05/01 16:54:18 Sorted in ascending order of channel Pressure [decibar] -REMOVECH 2024/05/01 16:55:13 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Descent_Rate [m/s] Status:Pump Altimeter [metres] Salinity:T1:C1 [PSS-78] Flag -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved' changed from mL/L to umol/kg -HEADER EDITS: 2024/05/02 13:10:05 Applied edit header: E:\Telework\2023-026\Processing\doc\HYDRO\2023-026-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F10.3 ==> F7.1 Channel 4: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 6: Transmissivity [%/metre] Name: Transmissivity:1 ==> Transmissivity Channel 7: Transmissivity:Green [%/metre] Name: Transmissivity:2 ==> Transmissivity:Green Channel 11: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 14: Number_of_bin_records [n/a] Pad: ' ' ==> -99 Channel 16: Temperature:Draw [deg C (ITS90)] Format: F7.2 ==> F6.1 Channel 18: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 20: Flag:Chlorophyll:Extracted [n/a] Units: ==> n/a Channel 24: Flag:Oxygen:Dissolved [n/a] Units: ==> n/a Pad: 0 ==> n/a Channel 26: Flag:Nitrate_plus_Nitrite [n/a] Units: ==> n/a Channel 28: Flag:Silicate [n/a] Units: ==> n/a Channel 30: Flag:Phosphate [n/a] Units: ==> n/a Channel 9: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 13: Conductivity:Primary [S/m] Format: F11.6 ==> F10.5 $END *COMMENTS Sample_Number 196: ALL: Niskin leaking from bottom cap. OXY: Two small bubbles inside sample. Sample_Number 197: OXY: Bubble inside sample. Sample_Number 199: OXY-1: Small bubble inside sample. Sample_Number 200: OXY: Two small bubbles inside sample. Sample_Number 201: ALL: Niskin spigot was leaking prior to sampling. Sample_Number 205: OXY: Analyst forgot to place dose tip in sample prior to titration initiation. Sample open for a few minutes during reset. Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters after collection, and immediately frozen and stored in a -80C freezer until analysis. All samples were returned to the Institute of Ocean Sciences and analyzed 10-11 weeks after the cruise on a Turner Trilogy 7200-000 fluorometer, using methods described in Holm-Hansen et al (1965). Fluorescence readings taken before and after sample acidification were used to calculate chlorophyll and phaeopigment concentrations. For details on methodology, see document QF2023-026_CHL*.xlsx Methodology sheet. NOTE: Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeo-Pigment values. Oxygen samples were analyzed at sea using an automated Winkler titration System (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a precision analysis, see document QF2023-026OXY*.xlsx. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater 22 - 34 days after collection. For details including a duplicate analysis, see document QF2023-026SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20C freezer. For samples 400m and deeper a second set of samples are collected and stored cool for silicate analysis. All samples were returned to the Insitute of Ocean Sciences and they were analyzed using an Astoria-Pacific Analyzer following methods described in "IOS Nutrient Methods (1996) Barwell-Clarke and Whitney". For details including a duplicate analysis, see document QF2023-026nuts*.xlsx. The ammonium method used at IOS is a modification of the fluorometric technique of Holmes et al, 1999. The method uses a single working reagent and minimizes contamination, can be applied to a large range of ammonium concentrations, and allows for samples to be processed quickly in the field. Samples are collected during the day into vials cleaned with working reagent, and stored in the Cold Room on the Tully. Working standards that bracket the expected sample concentrations are made up daily from seawater low in organic matter, collected on 2023-066, station P23, at 2005m. Samples and standards are spiked with working reagent at the same time, and allowed to incubate for 8-18 hours to maximize fluoroescence signal and stability. The fluoroscence is then read using a Turner Trilogy fluorometer in raw fluoroscence mode. A linear calibration curve is generated from the standards, and the calibration equation then applied to sample fluoroscene to determine sample concentration. For more details, please see the Methodology tab of file QF2022-026NH4*.xlsx. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. 5. Holmes, R.M., Aminot, A., Kérouel, R., Hooker, B. A., and Peterson, B.J. (1999). A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Can. J. Fish. Aquat. Sci., 56: 1801-1808. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Conductivity, Transmissivity and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. NOTE: While the CTD fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. There were 2 WetLabs CStar transmissometers in use during this cruise: Channel Transmissometer refers to sensor #1185DR (650nm - red) Channel Transmissometer:Green refers to sensor #1883DG (530nm - green) For comparison with other Institute of Ocean Sciences cruises, note that the transmissometer wavelength is 650nm unless otherwise stated. For details on the processing see the report: 2023-026_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.53E-02 1) Salinity:T1:C1 PSS-78 10 -99 () (0.63E-02 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.113E-01 1.0227) $END !1- 2- --3--- --4--- ---5---- --6-- --7-- ---8--- --9--- ---10--- --11-- --12- ----13--- -14- -15- --16- ---17--- 18 --19-- 20 --21-- ---22-- --23- 24 --25-- 26 --27-- 28 ---29-- 30 --31-- 32 !Bo Bo Pressu Depth Temperat Trans Trans Fluores PAR Salinity Oxygen Oxyge Conductiv Numb Samp Tempe Salinity Fl Chloro Fl Phaeo- Oxygen: Oxyge Fl Nitrat Fl Silica Fl Phospha Fl Ammoni Fl !tt tt re ure: missi missi cence: :T0:C0 : n: ity: er_o le_ ratur :Bottle ag phyll: ag Pigmen Dissolv n: ag e_ ag te ag te ag um ag !~u ~u Primary vity vity: URU: Dissol Disso Primary ~bin Numb e: ~o Extrac ~a t: ed Disso ~o plus_ ~t ~i ~p ~o !mb en Green Seapoin ved: lved: _rec er Draw tt ted ct Extrac lved lv Nitrit ri ca ha ni !er ce t SBE SBE ords le ed ted ed e te te te um !-- -- ------ ------ -------- ----- ----- ------- ------ -------- ------ ----- --------- ---- ---- ----- -------- -- ------ -- ------ ------- ----- -- ------ -- ------ -- ------- -- ------ -- *END OF HEADER 20 20 4.7 4.6 15.7675 53.2 71.2 2.181 0.2 32.2697 6.28 273.9 4.06084 71 215 17.3 32.2701 0 -99.00 0 -99.00 6.174 269.4 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 21 21 4.7 4.6 15.7310 51.0 67.5 2.071 0.2 32.2732 6.26 273.1 4.05787 241 216 -99.0 -99.0000 0 1.05 0 0.24 -99.000 -99.0 0 0.10 0 4.00 0 0.367 0 0.25 6 19 19 10.9 10.8 14.8875 44.8 57.2 3.184 0.0 32.2920 6.55 285.9 3.98275 241 214 16.5 32.2923 0 1.67 6 0.44 6.497 283.5 0 0.38 0 5.68 0 0.401 0 0.21 6 18 18 20.0 19.9 13.0188 45.9 57.8 3.604 0.0 32.3048 6.79 295.9 3.81446 241 213 14.8 32.3057 0 2.01 0 0.61 6.657 290.3 6 0.98 6 6.86 6 0.468 6 0.39 6 17 17 30.2 30.0 12.1258 52.8 69.0 2.006 0.0 32.3265 6.46 281.7 3.73669 241 212 13.6 32.3346 0 1.07 0 0.81 6.523 284.4 0 3.77 0 8.89 0 0.660 0 -99.00 0 16 16 50.3 49.8 9.0420 65.9 92.4 0.582 0.0 32.3915 6.68 290.9 3.47011 241 211 11.4 32.3961 0 0.31 0 0.33 6.625 288.7 0 6.97 0 9.00 0 0.918 0 -99.00 0 15 15 75.5 74.8 8.3337 69.0 98.2 0.234 0.0 32.8636 5.03 219.2 3.45393 241 210 11.0 32.8748 0 -99.00 0 -99.00 4.983 217.1 0 17.31 0 17.94 0 1.447 0 -99.00 0 14 14 100.1 99.2 7.9586 69.8 99.1 0.128 0.0 33.3991 3.90 169.9 3.47207 241 209 10.7 33.4025 0 -99.00 0 -99.00 3.883 169.1 0 24.19 0 27.66 0 1.809 0 -99.00 0 13 13 125.8 124.7 7.7716 70.0 99.3 0.090 0.0 33.6955 3.33 145.0 3.48411 241 208 10.3 33.6981 0 -99.00 0 -99.00 3.313 144.2 0 27.46 0 33.44 0 2.010 0 -99.00 0 12 12 150.3 149.0 7.6481 70.0 99.5 0.092 0.0 33.8115 3.06 133.0 3.48486 241 207 10.1 33.8127 0 -99.00 0 -99.00 3.034 132.1 0 28.65 0 36.87 0 2.066 0 -99.00 0 11 11 175.1 173.6 7.4321 69.9 99.2 0.088 0.0 33.8798 2.72 118.3 3.47282 241 206 10.0 33.8802 0 -99.00 0 -99.00 2.712 118.0 0 30.27 0 41.60 0 2.180 0 -99.00 0 10 10 200.3 198.5 6.9589 69.9 99.2 0.088 0.0 33.8864 2.72 118.2 3.43203 241 205 9.5 33.8886 0 -99.00 0 -99.00 2.696 117.3 3 31.25 0 45.51 0 2.231 0 -99.00 0 9 9 250.9 248.6 6.6227 70.0 99.4 0.089 0.0 33.9484 2.11 91.6 3.40978 241 204 9.4 33.9419 0 -99.00 0 -99.00 2.143 93.3 6 34.06 0 52.75 0 2.433 0 -99.00 0 8 8 300.3 297.6 6.3286 70.2 99.6 0.088 0.0 34.0013 1.58 68.9 3.39041 241 203 8.9 34.0026 0 -99.00 0 -99.00 1.596 69.4 0 36.43 0 60.53 0 2.635 0 -99.00 0 7 7 400.2 396.4 5.7272 70.1 99.5 0.089 0.0 34.0537 1.07 46.4 3.34584 241 202 8.6 34.0535 0 -99.00 0 -99.00 1.081 47.0 0 39.24 0 72.57 0 2.883 0 -99.00 0 6 6 501.1 496.2 5.2043 70.2 99.7 0.089 0.0 34.1059 0.71 31.0 3.30840 241 201 8.1 34.1056 0 -99.00 0 -99.00 0.728 31.7 3 41.59 0 84.23 0 3.043 0 -99.00 0 5 5 750.7 743.0 4.4115 69.7 98.7 0.095 0.0 34.2700 0.23 10.0 3.26329 241 200 7.5 34.2699 6 -99.00 0 -99.00 0.256 11.1 3 43.98 0 108.31 0 3.258 0 -99.00 0 4 4 1000.4 989.6 3.7932 70.1 99.3 0.095 0.0 34.3745 0.21 9.1 3.22840 241 199 7.1 34.3752 0 -99.00 0 -99.00 0.222 9.7 36 44.94 0 126.32 0 3.314 0 -99.00 0 3 3 1250.1 1235.8 3.1269 70.0 99.2 0.094 0.0 34.4494 0.34 14.9 3.18675 241 198 6.5 34.4503 0 -99.00 0 -99.00 0.355 15.4 0 45.08 6 145.15 6 3.316 6 -99.00 0 2 2 1499.8 1481.8 2.6755 70.1 99.4 0.095 0.0 34.4989 0.56 24.4 3.16181 241 197 6.0 34.4990 0 -99.00 0 -99.00 0.587 25.5 3 44.86 0 157.64 0 3.223 0 -99.00 0 1 1 1598.0 1578.4 2.4391 69.9 99.4 0.095 0.0 34.5269 0.75 32.6 3.14755 241 196 6.3 -99.0000 0 -99.00 0 -99.00 0.775 33.7 4 44.08 0 166.62 0 3.175 0 -99.00 0