*2023/02/20 12:00:13.68 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2022/07/16 08:04:03.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 13 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : A7FEF74A NUMBER OF CHANNELS : 24 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 13 2 Bottle:Firing_Sequence n/a 1 13 3 Pressure decibar 3.581 202.962 4 Depth metres 3.55 201.115 5 Temperature:Primary 'deg C (ITS90)' 7.836 12.3789 6 Transmissivity %/metre 26.7 53.3 7 Transmissivity:Green %/metre 39 82.5 8 Salinity:T0:C0 PSS-78 30.8733 33.1045 9 Oxygen:Dissolved:SBE mL/L 2.409 5.896 10 Oxygen:Dissolved:SBE umol/kg 104.9 257.3 11 Conductivity:Primary S/m 3.437187 3.612149 12 Number_of_bin_records n/a 50 241 13 Sample_Number n/a 4 16 14 Salinity:Bottle PSS-78 30.8819 33.1033 15 Flag:Salinity:Bottle ' ' 16 Chlorophyll:Extracted mg/m^3 0.8 1.49 17 Flag:Chlorophyll:Extracted ' ' 18 Phaeo-Pigment:Extracted mg/m^3 0.56 0.72 19 Nitrate_plus_Nitrite umol/L 5.67 28.4 20 Flag:Nitrate_plus_Nitrite ' ' 21 Silicate umol/L 10.7 46.46 22 Flag:Silicate ' ' 23 Phosphate umol/L 0.764 2.338 24 Flag:Phosphate ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 10 F ' ' 6 12 ' ' ' ' 5 I I 0 13 -99 ' ' 5 I I 0 14 -99 ' ' 9 F R4 4 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' 7 F R4 2 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 7 F R4 2 19 -99 ' ' 7 F R4 2 20 0 ' ' 3 NQ C ' ' 21 -99 ' ' 7 F R4 2 22 0 ' ' 3 NQ C ' ' 23 -99 ' ' 8 F R4 3 24 0 ' ' 3 NQ C ' ' $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2022-069 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Moorings SCIENTIST : Spear D. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : B.C. Coast STATION : Q3 EVENT NUMBER : 12 LATITUDE : 50 29.66000 N ! (deg min) LONGITUDE : 127 46.28000 W ! (deg min) WATER DEPTH : 204 ALTIMETER (M) : 5.67 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 2374 Conductivity ' ' 3184 'Pressure:Digiquartz with TC' ' ' 0506 Temperature:2 ' ' 4883 Conductivity:2 ' ' 4395 'Oxygen:SBE 43' ' ' 0997 Fluorometer:Seapoint ' ' 3982 Altimeter ' ' 76341 'Transmissometer:WET Labs C-Star' ' ' 1185DR 'Transmissometer:WET Labs C-Star:2' ' ' 1883DG $END $REMARKS Software Version Seasave V 7.26.7.121 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.3 2023/01/30 12:45:13 2448 2448 CLEAN 5.3 2023/01/30 12:45:34 2448 2448 ADDSAMP 3.6 2023/01/30 14:31:06 2448 2448 BINAVE 4.2.1 2023/01/30 14:31:21 2448 13 MERGE 3.6 2023/02/08 09:03:58 13 13 CLEAN 5.3 2023/02/08 09:04:04 13 13 CALIB 12.1 2023/02/20 11:11:29 13 13 CALIB 12.1 2023/02/20 11:12:41 13 13 SORT 3.6 2023/02/20 11:33:14 13 13 REMOVECH 8.2 2023/02/20 11:34:28 13 13 CHGUNITS 3.2 2023/02/20 11:36:22 13 13 CHGUNITS 3.2 2023/02/20 11:38:46 13 13 REORDER 1.3.1 2023/02/20 12:00:03 ? ? HDREDIT2 3.2 2023/02/20 12:00:13 ? ? $END $REMARKS -CLEAN functions: 2023/01/30 12:45:33 20 Reset #RECS, MIN & MAX values in header. Interpolation by Channel 1: Scan_Number [n/a] in Pressure Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: D:\Telework\2022-069\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2023/02/08 09:03:58 Merge Channel: Bottle_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolved, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total, Ammonium, Flag:Ammonium Primary file : D:\Telework\2022-069\Processing\hydro\2022-069-0012.samavg Secondary file: D:\Telework\2022-069\Processing\hydro\2022-069-0012.mrgcln1s 13 secondary records matched to primary records. Comments from secondary file: D:\Telework\2022-069\Processing\hydro\2022-069-0012.mrgcln1s ------------------------------------------------------------ -SORT parameters: 2023/02/08 09:03:35 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2023/02/08 09:04:04 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Remove Sea-Bird comments from the header. -CALIB parameters: 2023/02/20 11:11:29 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = D:\Telework\2022-069\Processing\doc\2022-069-recal-SIL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 30 Silicate umol/L 120 0.9040000E+00 0.3000000E-02 0.2500000E+02 Salinity:T0:C0 -CALIB parameters: 2023/02/20 11:12:41 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = D:\Telework\2022-069\Processing\doc\2021-069-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 15 Salinity:T1:C1 PSS-78 10 0.1240000E-01 0.1000000E+01 16 Oxygen:Dissolved:SBE mL/L 10 0.1400000E-01 0.1038100E+01 -SORT parameters: 2023/02/20 11:33:14 Sorted in ascending order of channel Pressure -REMOVECH 2023/02/20 11:34:28 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Secondary [S/m] Fluorescence:URU:Seapoint [mg/m^3] Oxygen:Voltage:SBE [volts] Salinity:T1:C1 [PSS-78] Status:Pump Descent_Rate [m/s] Altimeter [metres] Flag -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T0:C0 [PSS-78] - No units changed -HEADER EDITS: 2023/02/20 12:00:13 Applied edit header: D:\Telework\2022-069\Processing\doc\HYDRO\2022-069-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 4: Depth [metres] Name: Depth:Salt_Water ==> Depth Channel 11: Conductivity:Primary [S/m] Format: F8.3 ==> F10.6 Channel 6: Transmissivity [%/metre] Name: Transmissivity:1 ==> Transmissivity Format: F8.3 ==> F6.1 Channel 7: Transmissivity:Green [%/metre] Name: Transmissivity:2 ==> Transmissivity:Green $END *COMMENTS Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters after collection and immediately frozen and stored in a -80C freezer until analysis. All samples were returned to the Institute of Ocean Sciences after collection. Samples were analyzed on a Turner Trilogy 7200-000 fluorometer, using methods described in Holm-Hansen et al (1965). Fluorescence readings taken before and after sample acidification were used to calculate chlorophyll and phaeopigment concentrations. Chlorophyll samples were analyzed at IOS in Room 2423 5 weeks after the cruise. For further details on methodology, see document QF 2022-069_CHL_ *.xlsx Methodology sheet. Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeo-Pigment values Oxygen samples were analyzed at sea using an automated Winkler titration System (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2022-069OXY*.xlsx. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater 3 - 33 days after collection. For details see document QF2022-069SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20C freezer. For samples 400m and deeper a second set of samples are collected and stored cool for silicate analysis. All samples were returned to the Institute of Ocean Sciences and analyzed using an Astoria-Pacific and the SEAL AA3 following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2022-069nuts*.xlsx. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Conductivity and Transmissivity data are nominal and unedited except that some records were removed in editing temperature and salinity. Fluorometer # 3982 malfunctioned. It was used for events #2-135. Data from the top 20m were lower compared to extracted chlorophyll samples than is usual for this type of sensor. Deep values varied from 0 to high values with noisy sections. Files that include fluorescence may be obtained by sending a request to: PAC SCI IOS Data / Données ISO SCI PAC (DFO/MPO) For events #136-145 fluorometer #3641 was used and performed normally. The data are considered nominal and are unedited except that some records were removed in editing temperature and salinity. While the SBE fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. There were 2 WetLabs CStar transmissometers in use during this cruise: Channel Transmissometer refers to sensor #1185DR (650nm - red) Channel Transmissometer:Green refers to sensor #1883DG (530nm - green) For comparison with other Institute of Ocean Sciences cruises, note that the transmissometer wavelength is 650nm unless otherwise stated. Silicate values were corrected if CTD salinity was <25psu. For details on the processing see the report: 2022-069_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Silicate umol/L 120 -99 (Salinity:T0:C0) (0.904 0.3E-02 25) Salinity:T1:C1 PSS-78 10 -99 () (0.124E-01 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.14E-01 1.0381) $END !1- 2- --3--- --4--- ---5---- --6-- --7-- ---8---- --9--- --10- ----11--- -12- -13- ---14--- 15 --16-- 17 --18-- --19-- 20 --21-- 22 ---23-- 24 !Bo Bo Pressu Depth Temperat Trans Trans Salinity Oxygen Oxyge Conductiv Numb Samp Salinity Fl Chloro Fl Phaeo- Nitrat Fl Silica Fl Phospha Fl !tt tt re ure: missi missi :T0:C0 : n: ity: er_o le_ :Bottle ag phyll: ag Pigmen e_ ag te ag te ag !~u ~u Primary vity vity: Dissol Disso Primary ~bin Numb ~o Extrac ~a t: plus_ ~t ~i ~p !mb en Green ved: lved: _rec er tt ted ct Extrac Nitrit ri ca ha !er ce SBE SBE ords le ed ted e te te te !-- -- ------ ------ -------- ----- ----- -------- ------ ----- --------- ---- ---- -------- -- ------ -- ------ ------ -- ------ -- ------- -- *END OF HEADER 11 11 3.6 3.5 12.2353 45.4 66.8 30.8738 5.90 257.3 3.594000 50 14 -99.0000 0 1.45 0 0.72 5.89 0 10.86 0 0.796 0 13 13 3.6 3.6 12.2336 45.2 66.8 30.8744 5.88 256.6 3.594000 241 16 -99.0000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 12 12 3.6 3.6 12.2328 45.3 66.9 30.8733 5.88 256.7 3.594000 53 15 30.8819 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 10 10 5.6 5.5 12.3789 45.3 66.8 30.9159 5.89 257.0 3.611000 241 13 -99.0000 0 1.49 0 0.58 5.67 0 10.70 0 0.764 0 9 9 10.1 10.0 12.3657 45.6 67.3 30.9350 5.87 256.2 3.612000 241 12 -99.0000 0 1.19 6 0.62 5.87 0 10.90 0 0.783 0 8 8 20.4 20.2 12.0276 48.6 72.1 31.0629 5.65 246.4 3.597000 241 11 -99.0000 0 0.80 0 0.56 6.84 0 12.06 0 0.863 0 7 7 30.5 30.2 11.2895 51.1 77.5 31.0588 5.39 235.1 3.533000 241 10 -99.0000 0 -99.00 0 -99.00 10.26 6 16.45 6 1.126 6 6 6 50.6 50.1 9.1153 53.3 82.5 32.2110 3.85 167.8 3.460000 241 9 32.4468 0 -99.00 0 -99.00 21.40 0 33.05 0 1.837 0 5 5 75.3 74.6 8.0929 47.3 71.5 32.9309 2.80 121.8 3.439000 241 8 -99.0000 0 -99.00 0 -99.00 26.39 0 41.37 0 2.104 0 4 4 100.3 99.5 7.9635 42.6 63.5 33.0166 2.64 114.9 3.437000 241 7 -99.0000 0 -99.00 0 -99.00 27.46 0 43.48 0 2.226 0 3 3 203.0 201.1 7.8362 27.0 39.5 33.1043 2.41 104.9 3.439000 241 6 -99.0000 0 -99.00 0 -99.00 28.40 0 46.46 0 2.338 0 2 2 203.0 201.1 7.8360 27.5 40.1 33.1045 2.41 104.9 3.439000 74 5 33.1033 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 1 1 203.0 201.1 7.8365 26.7 39.0 33.1043 2.41 105.0 3.439000 102 4 -99.0000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0