*2021/06/03 14:22:16.75 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2019/06/11 01:01:16.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 20 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : E8A9F0E0 NUMBER OF CHANNELS : 16 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 20 2 Bottle:Firing_Sequence n/a 1 20 3 Pressure decibar 10.3 2000.9 4 Depth metres 10.2 1974.3 5 Temperature:Primary 'deg C (ITS90)' 1.9752 10.2259 6 Conductivity:Primary S/m 3.127854 3.573095 7 Transmissivity %/metre 35.4 54.1 8 Transmissivity:Green %/metre 56.4 94.1 9 Fluorescence:URU:Seapoint mg/m^3 0.108 2.863 10 PAR uE/m^2/sec 0 121 11 Salinity:T0:C0 PSS-78 32.3919 34.5774 12 Oxygen:Dissolved:SBE mL/L 0.43 6.88 13 Oxygen:Dissolved:SBE umol/kg 18.9 299.9 14 Sample_Number n/a 551 570 15 Number_of_bin_records n/a 58 241 16 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 10 F ' ' 6 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 8 F ' ' 3 10 -99 ' ' 7 F ' ' 1 11 -99 ' ' 9 F ' ' 4 12 -99 ' ' 7 F ' ' 2 13 -99 ' ' 6 F ' ' 1 14 -99 ' ' 5 I I 0 15 ' ' ' ' 5 I I 0 16 0 ' ' 3 NQ C ' ' $END $REMARKS Quality flags have the following significance: ---------------------------------------------------------------------------------- 0 = Acceptable measurement with no header comment 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable measurement with header comment 3 = Questionable measurement (Probably Good) 4 = Poor measurement (Probably Bad) 5 = Measurement not reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2019-006 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P26 EVENT NUMBER : 79 LATITUDE : 50 0.07000 N ! (deg min) LONGITUDE : 145 0.02000 W ! (deg min) WATER DEPTH : 4250 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 LOCATION : Mid-ship ! custom item $REMARKS Software Version Seasave V 7.26.7.107 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.2.2 2019/10/10 09:19:05 3811 3811 CLEAN 5.2.3 2019/10/10 09:25:13 3811 3811 ADDSAMP 3.6 2019/10/10 10:44:42 3811 3811 BINAVE 4.2 2019/10/10 10:44:58 3811 20 MERGE 3.5 2019/11/13 13:43:16 20 20 CLEAN 5.2.3 2019/11/13 13:44:10 20 20 CALIB 12.0 2019/11/13 13:44:50 20 20 SORT 3.6 2019/11/13 13:45:13 20 20 REMOVECH 8.2 2019/11/13 13:45:44 20 20 CHGUNITS 3.1.1 2019/11/13 13:54:29 20 20 CHGUNITS 3.1.1 2019/11/13 14:20:34 20 20 REORDER 1.3.1 2019/11/13 14:21:48 ? ? HDREDIT2 3.1.1 2019/11/13 14:22:35 ? ? HDREDIT2 3.2 2020/12/10 11:15:18 ? ? REORDER 1.3.1 2020/12/10 11:15:56 ? ? HDREDIT2 3.2 2020/12/10 11:17:06 ? ? HDREDIT2 3.2 2020/12/10 11:19:13 ? ? CALIB 12.0.1 2021/01/20 10:25:07 20 20 REMOVECH 8.2 2021/06/03 13:28:56 20 20 MERGE 3.6 2021/06/03 13:52:47 20 20 REORDER 1.3.1 2021/06/03 14:22:16 ? ? $END $REMARKS -CLEAN functions: 2019/10/10 09:24:53 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2019/11/13 13:43:16 Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Temperature:Draw, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide, Dimethylsulfoniopropionate_Dissolved, Flag:Dimethylsulfoniopropionate_Dissolve, Dimethylsulfoniopropionate_Total, Flag:Dimethylsulfoniopropionate_Total Primary file : Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\hydro\2019-006-0079.samavg Secondary file: Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\hydro\2019-006-0079.mrgcln1s Comments from secondary file: Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\hydro\2019-006-0079.mrgcln1s --------------------------------------------------------------------------- -SORT parameters: 2019/11/13 13:42:50 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2019/11/13 13:44:07 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Remove Sea-Bird comments from the header. -CALIB parameters: 2019/11/13 13:44:50 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\doc\2019-006-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 18 Salinity:T0:C0 PSS-78 10 0.3400000E-02 0.1000000E+01 19 Salinity:T1:C1 PSS-78 10 0.6000000E-03 0.1000000E+01 20 Oxygen:Dissolved:SBE mL/L 10 0.1380000E-01 0.1035000E+01 -SORT parameters: 2019/11/13 13:45:13 Sorted in ascending order of channel Press* -REMOVECH 2019/11/13 13:45:44 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Descent_Rate [m/s] Status:Pump Salinity:T1:C1 [PSS-78] Flag -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T0:C0 [PSS-78] - No units changed -HEADER EDITS: 2019/11/13 14:22:35 Applied edit header: Q:\OSD_DataProcessing\Cruise_Data\2019-006\Processing\doc\HYDRO\2019-006-bot- hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F10.3 ==> F7.1 Channel 10: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 12: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 16: Salinity:Bottle [PSS-78] Units: ==> PSS-78 Channel 17: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 4: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 6: Conductivity:Primary [S/m] Format: F11.6 ==> F10.6 -HEADER EDITS: 2020/12/10 11:15:18 Channel 1: Bottle_Number [n/a] Format: I3 ==> I5 Channel 2: Bottle:Firing_Sequence [n/a] Format: I3 ==> I5 Channel 7: Transmissivity:Green [%/metre] Name: Transmissivity ==> Transmissivity:Green Channel 8: Transmissivity [%/metre] Name: Transmissivity2 ==> Transmissivity -HEADER EDITS: 2020/12/10 11:17:06 Channel 2: Bottle_Number [n/a] Format: I3 ==> I5 Channel 3: Bottle:Firing_Sequence [n/a] Format: I3 ==> I5 Channel 16: Salinity:Bottle [PSS-78] Format: F7.2 ==> F9.4 -HEADER EDITS: 2020/12/10 11:19:13 Applied edit header: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2019\2019-006-transmissivity\ 2019-006-trms-hdr1.txt -CALIB parameters: 2021/01/20 10:25:07 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = 2019-006-transcor.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Transmissivity:Green %/metre 10 -0.2000000E-01 0.1439800E+01 -REMOVECH 2021/06/03 13:28:56 The following CHANNEL(S) were removed: Salinity:Bottle [PSS-78] -MERGE *** Secondary file not found *** Primary file : Q:\OSD_DataProcessing\Cruise_Data\2019-006\old\2019-006-0079.rem Secondary file: Q:\OSD_DataProcessing\Cruise_Data\2019-006\old\2019-006-0079.nutcln 16 secondary records matched to primary records. $END *COMMENTS Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -80C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours in the lab and analyzed on a Turner 10AU fluorometer calibrated with commercially pure chlorophyll a standard (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed at IOS in Room 2423 ~2 weeks after the cruise. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). Flags and comments apply to chlorophyll values only. Precision Statement: Chlorophyll values ranged from 0.04-26.35ug/l in 108 samples. Average %CV for this cruise was 3.56% with 2 out of 33 duplicate pairs having a CV>10% and 0 duplicate pairs having a CV>30%. Our average dataset %CV is 3.80% for 2013 - 2018 so the overall quality of this dataset is very good. For details see worksheet “CV%” in file QF2019-006CHL*.xlsx. Oxygen samples were analyzed at sea using an automated Winkler titration System (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2019-006OXY*.xlsx. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer standardized with IAPSO standard seawater 31 - 50 days after collection. For details including a duplicate analysis, see document QF2019-006SAL*.xlsx. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in -20 freezer. One set of samples was collected and frozen immediately. Another set of samples from 400m and deeper (to be used for silicate analysis) was collected and stored at 4C in the dark. All samples were returned to IOS for analysis. They were analyzed using an Astoria analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2019-006nuts*.xlsx. DMS samples were collected in 250mL ground glass stoppered bottles and stored in a fridge, in the dark and removed one at a time before analysis. A sample was loaded onto the stripper and purged with UHP Nitrogen for 10 minutes at ~100mL/min. The DMS was extracted from the water and absorbed into a Tenax TA trap kept at -80C. The trap was subsequently desorbed at 100 deg C (with a dewar containing boiling water) onto a Chromosil 330 column which eluted onto a Flame Photometric Detector (FPD). All samples were run as soon as possible after being collected. The minimum detectable level for DMS is 0.10 nmol/L, so “0” values should be interpreted as <0.1nmol/L. DMS data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. For more detail see file "2019-006 DMS report.doc" and for data and duplicate analysis see "QF 2019-006 DMS*.xlsx." DMSP-D: Approximately 50-75mL of seawater was allowed to flow directly from the niskin into a filtration funnel containing a 0.7um GF/F filter. The first 3.5mL was collected in a polypropylene tube (15mL) containing 50uL of a 50% sulphuric acid solution. DMPS-T: 3.5mL of seawater was collected directly from the niskin into a polypropylene tube (15mL) containing 50uL of a 50% sulphuric acid solution. DMSP-D and DMSP-T: Samples are stored in the dark at 4 degrees C for a minimum of 24 hours. They are hydrolized and analyzed later at the Institute of Ocean Sciences. The minimum detectable level is 0.1 nM, so “0” values should be interpreted as <0.1 nM. DMSP data are limited to 2 significant figures. Unless otherwise indicated the % relative difference between duplicates is <20%. For details on analysis and raw data, see document "QF2019-006 dmsp*.xlsx. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. 5. Holmes, R.M., Aminto, A., Kérouel, R., Hooker, B. A., and Peterson, B.J. (1999). A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Can. J. Fish. Aquat. Sci., 56: 1801-1808. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Conductivity, Transmissivity, Fluorescence:URU:Seapoint and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. There were 2 WetLabs CStar transmissometers in use during this cruise: Channel Transmissometer refers to sensor #1185DR (650nm - red) Channel Transmissometer:Green refers to sensor #1883DG (530nm - green) For comparison with other Institute of Ocean Sciences cruises, note that the transmissometer wavelength is 650nm unless otherwise stated. NOTE: While the CTD fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. For details on the processing see the report: 2019-006_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- --------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.34E-02 1) Salinity:T1:C1 PSS-78 10 -99 () (0.6E-03 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.138E-01 1.035) Transmissivity:Green %/metre 10 -99 () (-0.2E-01 1.4398) $END !1- 2- --3--- --4--- ---5---- ----6---- --7-- --8-- ---9--- --10-- ---11--- --12-- --13- -14- -15- 16 !Bo Bo Pressu Depth Temperat Conductiv Trans Trans Fluores PAR Salinity Oxygen Oxyge Samp Numb Fl !tt tt re ure: ity: missi missi cence: :T0:C0 : n: le_ er_o ag !~u ~u Primary Primary vity vity: URU: Dissol Disso Numb ~bin ~o !mb en Green Seapoin ved: lved: er _rec tt !er ce t SBE SBE ords le !-- -- ------ ------ -------- --------- ----- ----- ------- ------ -------- ------ ----- ---- ---- -- *END OF HEADER 18 18 10.3 10.2 10.2246 3.572973 35.4 56.6 2.836 110.2 32.3920 6.88 299.8 568 171 0 19 19 10.3 10.2 10.2254 3.573060 35.4 56.4 2.792 110.5 32.3921 6.88 299.7 569 176 0 20 20 10.3 10.2 10.2259 3.573095 35.4 56.7 2.748 121.0 32.3921 6.88 299.9 570 241 0 17 17 10.3 10.2 10.2235 3.572867 35.4 56.6 2.863 104.8 32.3919 6.88 299.7 567 238 0 15 15 499.7 494.9 3.9475 3.198052 53.9 93.6 0.110 0.0 34.1100 0.88 38.2 565 58 0 14 14 499.9 495.1 3.9462 3.197983 53.9 93.6 0.111 0.0 34.1104 0.88 38.0 564 177 0 16 16 500.0 495.1 3.9489 3.198139 53.9 93.6 0.110 0.0 34.1095 0.88 38.1 566 241 0 13 13 500.1 495.2 3.9456 3.197950 53.9 93.4 0.110 0.0 34.1106 0.88 38.0 563 184 0 9 9 999.7 988.7 2.9621 3.155283 54.0 93.7 0.110 0.0 34.3701 0.43 18.9 559 167 0 10 10 999.7 988.8 2.9623 3.155304 54.0 93.7 0.110 0.0 34.3701 0.43 18.9 560 83 0 11 11 999.8 988.9 2.9620 3.155284 54.0 93.7 0.110 0.0 34.3701 0.43 18.9 561 241 0 12 12 999.9 989.0 2.9621 3.155297 54.0 93.7 0.110 0.0 34.3701 0.43 18.9 562 241 0 1 1 2000.6 1974.0 1.9758 3.127886 54.1 94.1 0.109 0.0 34.5773 1.14 49.3 551 132 0 6 6 2000.7 1974.1 1.9753 3.127854 54.1 94.1 0.109 0.0 34.5774 1.14 49.4 556 241 0 2 2 2000.7 1974.1 1.9758 3.127899 54.1 94.1 0.110 0.0 34.5773 1.14 49.4 552 241 0 8 8 2000.8 1974.2 1.9753 3.127855 54.1 94.1 0.109 0.0 34.5774 1.14 49.4 558 241 0 5 5 2000.9 1974.3 1.9754 3.127863 54.1 94.1 0.109 0.0 34.5773 1.14 49.4 555 241 0 3 3 2000.9 1974.3 1.9758 3.127903 54.1 94.1 0.109 0.0 34.5773 1.14 49.4 553 220 6 7 7 2000.9 1974.3 1.9752 3.127856 54.1 94.1 0.108 0.0 34.5774 1.14 49.5 557 63 0 4 4 2000.9 1974.3 1.9757 3.127890 54.1 94.1 0.109 0.0 34.5773 1.14 49.4 554 214 0