*2016/12/08 09:47:22.18 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2016/08/19 11:18:27.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 18 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 212EC023 NUMBER OF CHANNELS : 23 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 23 2 Bottle:Firing_Sequence n/a 1 18 3 Pressure decibar 2.955 249.492 4 Temperature:Secondary 'deg C (ITS90)' 6.6076 13.0252 5 Transmissivity %/metre 23.4 59.7 6 Fluorescence:URU:Seapoint mg/m^3 0.79E-01 7.11 7 PAR uE/m^2/sec 0 0.58E-01 8 Salinity:T1:C1 PSS-78 32.1213 33.9501 9 Oxygen:Dissolved:SBE mL/L 2.196 6.982 10 Oxygen:Dissolved:SBE umol/kg 95.5 304.3 11 Number_of_bin_records n/a 87 241 12 Sample_Number n/a 162 179 13 Salinity:Bottle PSS-78 32.128 32.389 14 Flag:Salinity:Bottle ' ' 15 Chlorophyll:Extracted mg/m^3 4.41 8.3 16 Flag:Chlorophyll:Extracted ' ' 17 Phaeo-Pigment:Extracted mg/m^3 2.37 3.67 18 Nitrate_plus_Nitrite umol/L 0.3E-01 0.87 19 Flag:Nitrate_plus_Nitrite ' ' 20 Silicate umol/L 1.52 1.86 21 Flag:Silicate ' ' 22 Phosphate umol/L 0.293 0.439 23 Flag:Phosphate ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 7 F ' ' 1 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 ' ' ' ' 5 I I 0 12 -99 ' ' 5 I I 0 13 -99 ' ' 8 F R4 3 14 0 ' ' 3 NQ C ' ' 15 -99 ' ' 7 F R4 2 16 0 ' ' 3 NQ C ' ' 17 -99 ' ' 7 F R4 2 18 -99 ' ' 7 F R4 2 19 0 ' ' 3 NQ C ' ' 20 -99 ' ' 7 F R4 2 21 0 ' ' 3 NQ C ' ' 22 -99 ' ' 8 F R4 3 23 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ---------------------------------------------------------------------------------- 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2016-08 AGENCY : IOS, Ocean Sciences Division, Sidney COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P4 EVENT NUMBER : 26 LATITUDE : 48 39.53000 N ! (deg min) LONGITUDE : 126 40.13000 W ! (deg min) WATER DEPTH : 1291 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 LOCATION : Mid-ship ! custom item $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 4752 Conductivity ' ' 2280 'Pressure:Digiquartz with TC' ' ' 0443 Temperature:2 ' ' 2710 Conductivity:2 ' ' 2754 'Oxygen:SBE 43' ' ' 0997 Fluorometer:Seapoint ' ' 3640 'Transmissometer:WET Labs C-Star' ' ' 1185DR Altimeter ' ' 62354 PAR/Irradiance:Biospherical/Licor ' ' 70613 $END $REMARKS SOFTWARE VERSION SEASAVE V 7.26.1.8 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 3.5 2016/11/16 13:50:02 3855 3855 CLEAN 5.2.1 2016/11/16 13:50:52 3855 3855 ADDSAMP 3.6 2016/11/16 17:15:37 3855 3855 BINAVE 4.2 2016/11/16 17:16:13 3855 18 MERGE 3.5 2016/12/06 16:50:40 18 18 CLEAN 5.2.1 2016/12/06 17:03:52 18 18 CALIB 11.9 2016/12/06 17:04:02 18 18 SORT 3.6 2016/12/06 17:04:20 18 18 REMOVECH 8.2 2016/12/06 17:04:31 18 18 CHGUNITS 3.1.1 2016/12/06 17:04:45 18 18 CHGUNITS 3.1.1 2016/12/06 17:04:59 18 18 REORDER 1.3.1 2016/12/06 17:05:14 ? ? HDREDIT2 3.0.2 2016/12/08 09:47:22 ? ? $END $REMARKS -CLEAN functions: 2016/11/16 13:50:43 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2016-08\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2016/12/06 16:50:40 Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2016-08\Processing\hydro\2016-08-0026.samavg Secondary file: P:\Cruise_Data_Processing\2016-08\Processing\hydro\2016-08-0026.mrgcln1s Comments from secondary file: P:\Cruise_Data_Processing\2016-08\Processing\hydro\2016-08-0026.mrgcln1s ------------------------------------------------------------------------ -SORT parameters: 2016/12/06 16:50:03 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2016/12/06 17:03:50 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* Set event to last 4 characters of file name -CALIB parameters: 2016/12/06 17:04:02 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2016-08\Processing\doc\2016-08-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 16 Salinity:T0:C0 PSS-78 10 0.4000000E-02 0.1000000E+01 18 Oxygen:Dissolved:SBE mL/L 10 0.5100000E-01 0.1017600E+01 -SORT parameters: 2016/12/06 17:04:20 Sorted in ascending order of channel Pressure* -REMOVECH 2016/12/06 17:04:31 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Descent_Rate [m/s] Status:Pump Salinity:T0:C0 [PSS-78] Flag -CHANGE units: Temperature reference channel: Temperature:Secondary Salinity reference channel: Salinity:T1:C1 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T1:C1 - No units changed -HEADER EDITS: 2016/12/08 09:47:22 Applied edit header: P:\Cruise_Data_Processing\2016-08\Processing\doc\HYDRO\2016-08-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F9.4 ==> F7.1 Channel 7: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 9: Oxygen:Dissolved:SBE [mL/L] Format: F11.3 ==> F7.2 Channel 13: Salinity:Bottle [PSS-78] Units: ==> PSS-78 Format: F9.4 ==> F8.3 Channel 15: Chlorophyll:Extracted [mg/m^3] Units: ==> mg/m^3 Format: F8.3 ==> F7.2 Channel 17: Phaeo-Pigment:Extracted [mg/m^3] Units: ==> mg/m^3 Channel 18: Nitrate_plus_Nitrite [umol/L] Units: ==> umol/L Format: F6.2 ==> F7.2 Channel 20: Silicate [umol/L] Units: ==> umol/L Channel 22: Phosphate [umol/L] Units: ==> umol/L $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\CTD Data\2016-08\2016-08-0026.hex Software Version Seasave V 7.26.1.8 Temperature SN = 4752 Conductivity SN = 2280 Number of Bytes Per Scan = 37 Number of Voltage Words = 4 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Aug 19 2016 11:25:27 NMEA Latitude = 48 39.53 N NMEA Longitude = 126 40.13 W NMEA UTC (Time) = Aug 19 2016 11:18:27 Store Lat/Lon Data = Append to Every Scan SBE 11plus V 5.1e number of scans to average = 1 pressure baud rate = 9600 NMEA baud rate = 4800 GPIB address = 1 advance primary conductivity 0.073 seconds advance secondary conductivity 0.073 seconds S> Mission: 2016-08 Ship: J.P. Tully Station: P4 Depth: 1291 Amanda++ cast System UTC = Aug 19 2016 11:25:27 # nquan = 19 # nvalues = 3855 # units = specified # name 0 = scan: Scan Count # name 1 = bpos: Bottle Position in Carousel # name 2 = nbf: Bottles Fired # name 3 = prDM: Pressure, Digiquartz [db] # name 4 = t090C: Temperature [ITS-90, deg C] # name 5 = t190C: Temperature, 2 [ITS-90, deg C] # name 6 = c0S/m: Conductivity [S/m] # name 7 = c1S/m: Conductivity, 2 [S/m] # name 8 = CStarTr0: Beam Transmission, WET Labs C-Star [%] # name 9 = flSP: Fluorescence, Seapoint # name 10 = par: PAR/Irradiance, Biospherical/Licor # name 11 = sbeox0V: Oxygen raw, SBE 43 [V] # name 12 = altM: Altimeter [m] # name 13 = dz/dtM: Descent Rate [m/s] # name 14 = pumps: Pump Status # name 15 = sal00: Salinity, Practical [PSU] # name 16 = sal11: Salinity, Practical, 2 [PSU] # name 17 = sbeox0ML/L: Oxygen, SBE 43 [ml/l] # name 18 = flag: 0.000e+00 # interval = seconds: 0.0416667 # start_time = Aug 19 2016 11:18:27 [NMEA time, header] # bad_flag = -9.990e-29 # # # # # 4752 # 16-Dec-15 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.35917908e-003 # 6.36752535e-004 # 2.08584233e-005 # 1.76255754e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 2280 # 19-Dec-14 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -1.00904009e+001 # 1.35149315e+000 # -1.84720682e-003 # 1.90856808e-004 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 0443 # 17-Dec-14 # -4.435292e+004 # -1.635794e-001 # 1.192740e-002 # 3.979900e-002 # 0.000000e+000 # 2.993627e+001 # -3.271008e-004 # 3.759160e-006 # 1.565300e-009 # 0.99991613 # -1.00000 # 0.000000e+000 # 1.282462e-002 # -8.599824e+000 # # # # # # 2710 # 16-Dec-15 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.36717385e-003 # 6.46681437e-004 # 2.34978657e-005 # 2.22502310e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 2754 # 19-Dec-14 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -1.05920237e+001 # 1.61356129e+000 # -1.94911294e-003 # 2.41671700e-004 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 0997 # 17-Jan-15 # 1 # # # 0.0000 # 0.0000e+000 # 0.0000 # 0.00e+000 # 0.0000 # 0.0 # # # # 4.0785e-001 # -0.6967 # -3.5082e-003 # 1.2934e-004 # -1.8411e-006 # 2.5826e+000 # 1.92634e-004 # -4.64803e-002 # 3.6000e-002 # 1.6200 #

-3.3000e-002

#

5.0000e+003

#

1.4500e+003

#
#
#
# # # # 3640 # # # 2 # 0.000 # # # # # # 1185DR # APR 27. 2016 # 19.3479 # -1.1028 # 0.250 # # # # # # # # # 62354 # # 15.000 # 0.000 # # # # # # # # # 70613 # 03/21/16 # 1.00000000 # 0.00000000 # 11876484560.57000000 # 1.00000000 # -0.08460813 # # # # # #
# datcnv_date = Nov 16 2016 13:46:22, 7.23.2 # datcnv_in = P:\Cruise_Data_Processing\2016-08\RAW\CTD\2016-08-0026.hex P:\Crui se_Data_Processing\2016-08\Processing\doc\2016-08-ctd.XMLCON # datcnv_ox_hysteresis_correction = yes # datcnv_ox_tau_correction = yes # datcnv_bottle_scan_range_source = BL file # datcnv_scans_per_bottle = 241 END* Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -80C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours in the lab and analyzed on a Turner 10AU fluorometer calibrated with commercially pure chlorophyll a standard (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed at IOS in Room 2423 within ~4 weeks of the cruise. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). Flags and comments apply to chlorophyll values only. Precision Statement: Chlorophyll values ranged from 0.02-43.38 ug/l. Average %CV for this cruise was 3.66% with 2 out of 63 duplicate pairs having a CV>15% and 0 out of 63 duplicate pairs having a CV>50%. Our average dataset %CV is 2.83 % for 2013 - 2015 so the overall quality of this dataset is very good. For details see worksheet “CV%” in file QF2016-08CHL*.xls. Oxygen samples were analyzed at sea using an automated Winkler titration system (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2016-08OXY*.xls. Salinity samples were collected in 200 mL type ll glass bottles with disposable nylon inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab at IOS on a Guildline 8410A Portasal Salinometer (S/N 58879) standardized with IAPSO standard seawater within 50 - 64 days after collection. Data are reported to the third decimal place on account of the reduced accuracy and precision from the delay in analysis and the slightly less accurate instrument (±0.001 PSU less accurate the the 8400B Autosal). For details including a duplicate analysis, see document QF2016-08SAL*.xls. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in -20 freezer. One set of samples was collected and frozen immediately. Another set of samples from 400m and deeper (to be used for silicate analysis) was collected and stored at 4C in the dark. All samples were returned to IOS for analysis. They were analyzed using an Astoria analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2016-08nuts*.xls. DMS samples were collected in 250mL ground glass stoppered bottles and stored in a fridge, in the dark and removed one at a time before analysis. A sample was loaded onto the stripper and purged with UHP Nitrogen for 10 minutes at ~100mL/min. The DMS was extracted from the water and absorbed on to a Tenax TA trap kept at -80C. The trap was subsequently desorbed at 100 deg C (with a dewar containing boiling water) onto a Choromasorb 330 column which eluted onto a Flame Photometric Detector (FPD). All samples were run as soon as possible after being collected. For more detail see file 2016-08DMS report.doc and for data and duplicate analysis see "DMS summary (2016-08 data).xls." The minimum detectable level for DMS is 0.10 nmol/L, so “0” values should be interpreted as <0.1nmol/L. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Transmissivity, Fluorescence and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". NOTE: While the CTD fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples, particularly for casts far from shore. It is recommended that users check extracted chlorophyll values where available. Dissolved oxygen was calibrated using the method described in SeaBird Application Note #64-2, June 2012 revision, except that a small offset in the fit was allowed. For details on the processing see the report: 2016-08_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.4E-02 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.51E-01 1.0176) $END !1- 2- --3--- ---4---- --5-- ---6--- --7--- ---8---- --9--- --10- -11- -12- ---13-- 14 --15-- 16 --17-- --18-- 19 --20-- 21 ---22-- 23 !Bo Bo Pressu Temperat Trans Fluores PAR Salinity Oxygen Oxyge Numb Samp Salinit Fl Chloro Fl Phaeo- Nitrat Fl Silica Fl Phospha Fl !tt tt re ure: missi cence: :T1:C1 : n: er_o le_ y: ag phyll: ag Pigmen e_ ag te ag te ag !~u ~u Secondar vity URU: Dissol Disso ~bin Numb Bottle ~o Extrac ~a t: plus_ ~t ~i ~p !mb en y Seapoin ved: lved: _rec er tt ted ct Extrac Nitrit ri ca ha !er ce t SBE SBE ords le ed ted e te te te !-- -- ------ -------- ----- ------- ------ -------- ------ ----- ---- ---- ------- -- ------ -- ------ ------ -- ------ -- ------- -- *END OF HEADER 20 17 3.0 13.0238 23.7 7.030 0.1 32.1214 6.98 304.3 133 176 32.142 0 7.68 0 3.67 0.03 0 1.55 0 0.312 0 18 15 3.0 13.0237 23.9 6.933 0.1 32.1215 6.98 304.1 90 174 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 23 18 3.1 13.0236 23.7 6.922 0.0 32.1215 6.98 304.1 241 179 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 2 13 3.1 13.0242 23.5 6.929 0.1 32.1213 6.97 303.6 241 163 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 17 14 3.1 13.0239 23.7 6.983 0.0 32.1214 6.97 304.0 182 173 -99.000 0 7.20 0 2.43 0.04 0 1.62 0 0.293 0 19 16 3.4 13.0239 23.4 7.110 0.0 32.1214 6.97 304.0 87 175 32.134 0 7.20 0 3.26 0.06 0 1.69 0 0.312 0 21 12 3.9 13.0231 23.8 7.044 0.0 32.1213 6.96 303.4 241 177 32.128 0 8.30 0 2.82 0.87 0 1.52 0 0.298 0 9 10 4.9 13.0252 23.5 7.027 0.0 32.1214 6.98 304.3 241 169 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 13 11 4.9 13.0244 23.7 6.951 0.0 32.1215 6.98 304.1 241 172 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 8 9 9.7 13.0228 24.9 6.934 0.0 32.1213 6.96 303.5 241 168 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 22 8 18.2 12.6796 39.9 3.198 0.0 32.1918 6.33 275.8 241 178 32.193 0 4.41 0 2.37 0.48 0 1.86 0 0.439 0 7 7 20.4 12.4949 40.6 3.062 0.0 32.2204 6.24 271.9 241 167 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 1 6 30.5 10.8591 40.5 3.070 0.0 32.3943 6.03 262.6 241 162 32.389 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 12 5 50.0 9.6505 56.2 0.395 0.0 32.5814 5.84 254.2 241 171 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 6 4 50.0 9.6411 56.4 0.383 0.0 32.5805 5.83 254.0 230 166 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 11 3 100.2 8.3001 58.7 0.133 0.0 33.4689 3.83 166.8 241 170 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 5 2 150.5 7.7840 59.4 0.088 0.0 33.8441 3.00 130.4 241 165 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0 4 1 249.5 6.6076 59.7 0.079 0.0 33.9501 2.20 95.5 241 164 -99.000 0 -99.00 0 -99.00 -99.00 0 -99.00 0 -99.000 0