*2015/08/28 13:50:39.48 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2015/06/09 13:09:58.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : E96AD23 NUMBER OF CHANNELS : 11 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 12 2 Bottle:Firing_Sequence n/a 1 12 3 Pressure decibar 10.927 1323.118 4 Temperature:Primary 'deg C (ITS90)' 2.9258 11.7698 5 Transmissivity %/metre 46.6 66 6 Fluorescence:URU:Seapoint mg/m^3 0.85E-01 3.449 7 Salinity:T0:C0 PSS-78 31.8849 34.4806 8 Oxygen:Dissolved:SBE mL/L 0.225 6.543 9 Oxygen:Dissolved:SBE umol/kg 9.8 285.2 10 Number_of_bin_records n/a 61 241 11 Sample_Number n/a 106 117 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 7 F ' ' 2 9 -99 ' ' 6 F ' ' 1 10 ' ' ' ' 5 I I 0 11 -99 ' ' 5 I I 0 $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ---------------------------------------------------------------------------------- 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2015-09 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P4 EVENT NUMBER : 16 LATITUDE : 48 38.99000 N ! (deg min) LONGITUDE : 126 39.99000 W ! (deg min) WATER DEPTH : 1315 ALTIMETER (M) : 8.99 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 LOCATION : Mid-ship ! custom item $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------------------------- -------------- ---------- Temperature ' ' 2023 Conductivity ' ' 1763 'Pressure:Digiquartz with TC' ' ' 0506 Temperature:2 ' ' 5013 Conductivity:2 ' ' 3394 'Oxygen:SBE 43' ' ' 1438 Fluorometer:Seapoint ' ' 3640 'Transmissometer:WET Labs C-Star' ' ' 1396DR Altimeter ' ' 62354 PAR/Irradiance:Biospherical/Licor ' ' 4565 $END $REMARKS SOFTWARE VERSION SEASAVE V 7.22.4 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 3.4.1 2015/07/31 14:44:34 2542 2542 CLEAN 5.2.1 2015/07/31 14:46:26 2542 2542 ADDSAMP 3.6 2015/08/11 11:40:17 2542 2542 BINAVE 4.2 2015/08/11 11:40:54 2542 12 MERGE 3.5 2015/08/28 11:55:22 12 12 CLEAN 5.2.1 2015/08/28 13:40:51 12 12 CALIB 11.8.1 2015/08/28 13:41:27 12 12 SORT 3.6 2015/08/28 13:41:41 12 12 REMOVECH 8.2 2015/08/28 13:42:30 12 12 CHGUNITS 3.1 2015/08/28 13:49:42 12 12 CHGUNITS 3.1 2015/08/28 13:50:01 12 12 REORDER 1.3.1 2015/08/28 13:50:07 ? ? HDREDIT2 3.0.2 2015/08/28 13:50:39 ? ? $END $REMARKS -CLEAN functions: 2015/07/31 14:46:19 20 Reset #RECS, MIN & MAX values in header. Interpolation by Channel 1: Scan_Number [n/a] in Pressure Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2015-09\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2015/08/28 11:55:22 Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2015-09\Processing\hydro\2015-09-0016.samavg Secondary file: P:\Cruise_Data_Processing\2015-09\Processing\hydro\2015-09-0016.mrgcln1s Comments from secondary file: P:\Cruise_Data_Processing\2015-09\Processing\hydro\2015-09-0016.mrgcln1s ------------------------------------------------------------------------ -SORT parameters: 2015/08/28 11:51:21 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2015/08/28 13:40:50 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -CALIB parameters: 2015/08/28 13:41:27 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2015-09\Processing\doc\2015-09-recal1.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 18 Oxygen:Dissolved:SBE mL/L 10 0.4520000E-01 0.1024600E+01 -SORT parameters: 2015/08/28 13:41:41 Sorted in ascending order of channel Pressure* -REMOVECH 2015/08/28 13:42:30 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] PAR [uE/m^2/sec] Altimeter [metres] Descent_Rate [m/s] Status:Pump Salinity:T1:C1 [PSS-78] Flag -CHANGE units: Temperature reference channel: Temperature:Primary Salinity reference channel: Salinity:T0:C0 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: Temperature reference channel: Temperature:Draw Salinity reference channel: Salinity:T0:C0 - No units changed -HEADER EDITS: 2015/08/28 13:50:39 Applied edit header: P:\Cruise_Data_Processing\2015-09\Processing\doc\HYDRO\2015-09-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Format: F9.4 ==> F7.1 Channel 8: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = E:\Data\2015-09\2015-09-0016.hex Software Version Seasave V 7.22.4 Temperature SN = 2023 Conductivity SN = 1763 Number of Bytes Per Scan = 37 Number of Voltage Words = 4 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Jun 09 2015 13:12:05 NMEA Latitude = 48 38.99 N NMEA Longitude = 126 39.99 W NMEA UTC (Time) = Jun 09 2015 13:09:58 Store Lat/Lon Data = Append to Every Scan SBE 11plus V 5.1e number of scans to average = 1 pressure baud rate = 9600 NMEA baud rate = 4800 GPIB address = 1 advance primary conductivity 0.073 seconds advance secondary conductivity 0.073 seconds advance voltage 6 0.000 seconds advance voltage 7 0.000 seconds S> Ship: J P Tully Cruise: 2015-09 Depth: 1315 Station: P4 System UTC = Jun 09 2015 13:12:05 # nquan = 19 # nvalues = 2542 # units = specified # name 0 = scan: Scan Count # name 1 = bpos: Bottle Position in Carousel # name 2 = nbf: Bottles Fired # name 3 = prDM: Pressure, Digiquartz [db] # name 4 = t090C: Temperature [ITS-90, deg C] # name 5 = t190C: Temperature, 2 [ITS-90, deg C] # name 6 = c0S/m: Conductivity [S/m] # name 7 = c1S/m: Conductivity, 2 [S/m] # name 8 = CStarTr0: Beam Transmission, WET Labs C-Star [%] # name 9 = flSP: Fluorescence, Seapoint # name 10 = sbeox0V: Oxygen raw, SBE 43 [V] # name 11 = par: PAR/Irradiance, Biospherical/Licor # name 12 = altM: Altimeter [m] # name 13 = dz/dtM: Descent Rate [m/s] # name 14 = pumps: Pump Status # name 15 = sal00: Salinity, Practical [PSU] # name 16 = sal11: Salinity, Practical, 2 [PSU] # name 17 = sbeox0ML/L: Oxygen, SBE 43 [ml/l] # name 18 = flag: 0.000e+00 # interval = seconds: 0.0416667 # start_time = Jun 09 2015 13:09:58 [NMEA time, header] # bad_flag = -9.990e-29 # # # # # 2023 # 31-Jan-13 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.11056177e-003 # 6.24714349e-004 # 1.97891287e-005 # 1.88702998e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 1763 # 01-Jan-14 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -4.22314873e+000 # 5.07768024e-001 # -5.15940128e-004 # 5.09668877e-005 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 0506 # 30-Dec-13 # -4.957807e+004 # -1.280011e+000 # 1.485710e-002 # 4.021200e-002 # 0.000000e+000 # 3.037224e+001 # -6.696188e-004 # 3.897170e-006 # 3.287590e-009 # 0.99997945 # -0.25000 # 0.000000e+000 # 1.280810e-002 # -9.210198e+000 # # # # # # 5013 # 27-Feb-13 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.36833110e-003 # 6.37693324e-004 # 2.08227492e-005 # 1.72454648e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 3394 # 03-Jan-14 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -9.62060268e+000 # 1.47483016e+000 # -1.36190582e-003 # 1.93968125e-004 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 1438 # 03-Jan-14 # 1 # # # 0.0000 # 0.0000e+000 # 0.0000 # 0.00e+000 # 0.0000 # 0.0 # # # # 4.7181e-001 # -0.5187 # -2.2511e-003 # 1.3917e-004 # -2.6436e-006 # 2.5826e+000 # 1.92634e-004 # -4.64803e-002 # 3.6000e-002 # 1.4300 #

-3.3000e-002

#

5.0000e+003

#

1.4500e+003

#
#
#
# # # # 3640 # # # 2 # 0.000 # # # # # # 1396DR # Feb 5tht 2014 # 19.0844 # -0.0191 # 0.250 # # # # # # # # # 62354 # # 15.000 # 0.000 # # # # # # # # # 4565 # Mar-16-2011 # 1.00000000 # 0.00000000 # 4115226337.44999980 # 1.00000000 # -0.36780000 # # # # # #
# datcnv_date = Jul 31 2015 12:21:23, 7.23.2 # datcnv_in = P:\Cruise_Data_Processing\2015-09\RAW\CTD\2015-09-0016.hex P:\Crui se_Data_Processing\2015-09\Processing\doc\2015-09-ctd.XMLCON # datcnv_ox_hysteresis_correction = yes # datcnv_ox_tau_correction = yes # datcnv_bottle_scan_range_source = BL file # datcnv_scans_per_bottle = 241 END* Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -80C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours in the lab and analyzed on a Turner 10AU fluorometer calibrated with commercially pure chlorophyll a standard (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed at IOS in Room 2423 ~3 weeks after the cruise. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). For details see worksheet “CV%” in file QF2015-09CHL*.xls. Flags and comments apply to chlorophyll values only. No flags or comments are assigned for Phaeopigment values. Oxygen samples were analyzed at sea using an automated Winkler titration system (Metrohm Dosimat model 876 and a UV light source and detector with a 365nm filter controlled by LV02_876 software designed and constructed by Scripps Institution of Oceanography) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2015-09OXY*.xls. Salinity samples were collected in 200 mL type ll glass bottles with disposable plastic inserts and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab at IOS on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater 13 to 37 days after collection. For details including a duplicate analysis, see document QF2015-09SAL*.xls. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in -20 freezer. One set of samples was collected and frozen immediately. Another set of samples from 400m and deeper (to be used for silicate analysis) was collected and stored at 4C in the dark. All samples were returned to IOS for analysis. They were analyzed using an Astoria analyzer following methods described in IOS Nutrient Methods (1996) Barwell-Clarke and Whitney. For details including a duplicate analysis, see document QF2015-09nuts*.xls. DMS samples were collected in 250mL ground glass stoppered bottles and stored in a fridge, in the dark and removed one at a time before analysis. A sample was loaded onto the stripper and purged with UHP Nitrogen for 10 minutes at ~100mL/min. The DMS was extracted from the water and absorbed on to a Tenax TA trap kept at -80C. The trap was subsequently desorbed at 100C (with a deware containing boiling water) onto a Choromasorb 330 column which eluted onto a Flame Photometric Detector (PFD). All samples were run as soon as possible after being collected. For more detail see file 2015-09 DMS report.doc and for data and duplicate analysis see "DMS summary (2015-09 data).xls." The minimum detectable level for DMS is 0.10 nmol/L, so “0” values should be interpreted as <0.10nmol/L. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers --------------------------------------------------------------------------------- CTD Data Processing Notes: -------------------------- Transmissivity, Fluorescence and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". Dissolved oxygen was calibrated using the method described in SeaBird Application Note #64-2, June 2012 revision, except that a small offset in the fit was allowed. For details on the processing see the report: 2015-09_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.452E-01 1.0246) $END !1- 2- --3--- ---4---- --5-- ---6--- ---7---- --8--- --9-- -10- -11- !Bo Bo Pressu Temperat Trans Fluores Salinity Oxygen Oxyge Numb Samp !tt tt re ure: missi cence: :T0:C0 : n: er_o le_ !~u ~u Primary vity URU: Dissol Disso ~bin Numb !mb en Seapoin ved: lved: _rec er !er ce t SBE SBE ords !-- -- ------ -------- ----- ------- -------- ------ ----- ---- ---- *END OF HEADER 12 12 10.9 11.7698 46.6 3.449 31.8849 6.54 285.2 241 117 11 11 49.9 10.5040 64.6 0.209 32.1958 5.99 260.8 241 116 10 10 100.2 8.8536 64.5 0.192 32.7124 5.16 224.5 241 115 9 9 200.8 7.3171 64.9 0.113 33.8482 2.91 126.5 241 114 8 8 400.1 5.4685 65.9 0.093 34.0043 1.31 56.8 241 113 7 7 599.9 4.6324 66.0 0.086 34.1607 0.44 19.1 241 112 5 5 799.3 4.0838 65.9 0.085 34.3019 0.23 9.8 71 110 6 6 800.0 4.0831 65.8 0.085 34.3021 0.23 9.8 241 111 4 4 1001.5 3.5550 65.7 0.085 34.3982 0.27 11.6 241 109 3 3 1002.6 3.5507 65.7 0.085 34.3988 0.27 11.5 61 108 2 2 1250.3 3.0808 65.4 0.093 34.4623 0.41 17.7 241 107 1 1 1323.1 2.9258 61.6 0.144 34.4806 0.46 20.1 241 106