*2014/11/20 09:58:13.04 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2012/04/04 16:40:37.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 3 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 86CEF67 NUMBER OF CHANNELS : 19 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 3 2 Bottle:Firing_Sequence n/a 1 3 3 Pressure decibar 1.75 1.76 4 Temperature:Secondary 'deg C (ITS90)' 7.3075 7.3101 5 Transmissivity %/metre 18.4 18.5 6 Fluorescence:URU:Wetlabs mg/m^3 11.24 11.295 7 Salinity:T1:C1 PSS-78 26.1719 26.244 8 Oxygen:Dissolved:SBE mL/L 8.588 8.599 9 Oxygen:Dissolved:SBE umol/kg 376 376 10 Number_of_bin_records n/a 57 241 11 Sample_Number n/a 43 44 12 Salinity:Bottle PSS-78 26.0297 26.0297 13 Flag:Salinity:Bottle n/a 14 Nitrate_plus_Nitrite umol/L 8.8 8.8 15 Flag:Nitrate_plus_Nitrite n/a 16 Silicate umol/L 11.3 11.3 17 Flag:Silicate n/a 18 Phosphate umol/L 0.93 0.93 19 Flag:Phosphate n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 7 F ' ' 2 9 -99 ' ' 6 F ' ' 1 10 ' ' ' ' 5 I I 0 11 -99 ' ' 5 I I 0 12 -99 ' ' 9 F R4 4 13 0 ' ' 3 NQ C ' ' 14 -99 ' ' 6 F R4 1 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' 6 F R4 1 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 7 F R4 2 19 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2012-19 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : SoG Moorings SCIENTIST : Johannessen S. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Strait of Georgia STATION : FR10 EVENT NUMBER : 18 LATITUDE : 49 9.91000 N ! (deg min) LONGITUDE : 123 32.83000 W ! (deg min) WATER DEPTH : 373 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $REMARKS SOFTWARE VERSION SEASAVE V 7.21B $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1.2 2012/06/08 11:52:47 355 355 CLEAN 5.0.4 2012/06/08 11:52:55 ? ? ADDSAMP 3.5 2012/06/08 11:53:05 355 355 BINAVE 4.1.1 2012/06/08 11:53:09 355 3 MERGE 3.4 2012/06/08 11:53:26 3 3 CLEAN 5.0.4 2012/06/11 09:55:37 3 3 CALIB 11.7 2012/06/11 09:55:46 3 3 CALIB 11.7 2012/06/11 09:55:58 3 3 SORT 3.5 2012/06/11 10:54:42 3 3 REMOVECH 8.1.1 2012/06/11 10:55:01 3 3 CHGUNITS 3.0 2012/06/11 11:24:12 3 3 CHGUNITS 3.0 2012/06/11 11:25:31 3 3 REORDER 1.3 2012/06/11 11:31:34 ? ? HDREDIT2 2.5.1 2012/06/11 11:34:58 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:38:07 3 3 HDREDIT2 2.6 2013/12/18 14:01:04 ? ? CHANGE_FLAGS 2.0 2014/11/20 09:58:13 3 3 $END $REMARKS -CLEAN functions: 2012/06/08 11:52:52 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2012-19\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2012/06/08 11:53:25 2012/06/08 11:53:25 2012/06/08 11:53: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Event_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2012-19\Processing\hydro\2012-19-0018.samavg Secondary file: P:\Cruise_Data_Processing\2012-19\Processing\hydro\2012-19-0018.mrgcln1s -SORT parameters: 2012/06/07 16:26:23 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2012/06/11 09:55:36 20 Reset #RECS, MIN & MAX values in header. Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2012/06/11 09:55:46 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2012-19\Processing\doc\2012-19-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 3 Pressure dbars 10 0.1200000E+01 0.1000000E+01 -CALIB parameters: 2012/06/11 09:55:58 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2012-19\Processing\doc\2012-19-recal2.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 17 Salinity:T1:C1 PSS-78 10 0.5000000E-02 0.1000000E+01 -SORT parameters: 2012/06/11 10:54:42 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2012/06/11 10:55:01 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] pH:SBE [pH Units] Altimeter [metres] Status:Pump Descent_Rate [m/s] Salinity:T0:C0 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: - No units changed -HEADER EDITS: 2012/06/11 11:34:58 Applied edit header: P:\Cruise_Data_Processing\2012-19\Processing\doc\HYDRO\2012-19-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 6: Fluorescence:URU:Wetlabs [mg/m^3] Name: Fluorescence:Wetlabs:ECO-AFL ==> Fluorescence:URU:Wetlabs Channel 7: Salinity:Practical:T1:C1 [PSS-78] Name: Salinity:T1:C1 ==> Salinity:Practical:T1:C1 Channel 8: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 9: Oxygen:Dissolved:SBE [umol/kg] Format: F6.0 ==> F6.1 Channel 12: Salinity:Bottle [PSS-78] Units: ==> PSS-78 Channel 13: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 14: Nitrate_plus_Nitrite [umol/L] Units: ==> umol/L Channel 15: Flag:Nitrate_plus_Nitrite [n/a] Units: ==> n/a Channel 16: Silicate [umol/L] Units: ==> umol/L Format: F7.2 ==> F6.1 Channel 17: Flag:Silicate [n/a] Units: ==> n/a Channel 18: Phosphate [umol/L] Units: ==> umol/L Channel 19: Flag:Phosphate [n/a] Units: ==> n/a -HEADER EDITS: 2013/12/18 14:01:04 - none. $END *COMMENTS Sample_Number 44: NO3: poor dup Analysis methods: ----------------- Oxygen samples were analyzed at sea using an automated Winkler titration system (Brinkmann Dosimat model 765 and a PC950 Colorimeter controlled by AutoOxy software V3.4) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). Oxygen values are reported to 2 decimal places only due to analyst's concern over precision. For details including a duplicate analysis, see document QF2012-19oxy*.xls. Salinity samples were collected in 200 mL type ll glass bottles with reusable silicone inserts supplied by Xiamen Cuten Accessories Industry Limited and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater 20 days after collection. Full details including a duplicate analysis are in file QF2012-19SAL*.xls. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in a -20 freezer. They were later analysed at IOS using an Astoria analyzer following methods described in Barwell-Clarke and Whitney (1996). For details including a duplicate analysis see file QF2012-19nuts*.xls. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Data Processing Notes: ---------------------- Transmissivity and SBE Fluorescence data are nominal and unedited. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". SBE DO calibration was done using the method described in the SeaBird Application NOte #64-2. For further processing details see the processing report 2012-19-proc.doc. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Pressure dbars 10 -99 () (1.2 1) Salinity:T1:C1 PSS-78 10 -99 () (0.5E-02 1) $END !1- 2- --3--- ---4---- --5-- ---6--- ---7---- --8--- --9-- -10- -11- ---12--- 13 --14- 15 --16- 17 --18-- 19 !Bo Bo Pressu Temperat Trans Fluores Salinity Oxygen Oxyge Numb Samp Salinity Fl Nitra Fl Silic Fl Phosph Fl !tt tt re ure: missi cence: :T1:C1 : n: er_o le_ :Bottle ag te_ ag ate ag ate ag !~u ~u Secondar vity URU: Dissol Disso ~bin Numb ~o plus_ ~t ~i ~p !mb en y Wetlabs ved: lved: _rec er tt Nitri ri ca ha !er ce SBE SBE ords le te te te te !-- -- ------ -------- ----- ------- -------- ------ ----- ---- ---- -------- -- ----- -- ----- -- ------ -- *END OF HEADER 2 2 1.8 7.3080 18.5 11.267 26.2074 8.59 376.0 57 44 -99.0000 0 8.8 36 11.3 6 0.93 6 3 3 1.8 7.3101 18.4 11.240 26.2440 8.59 376.0 241 -99 -99.0000 0 -99.0 0 -99.0 0 -99.00 0 1 1 1.8 7.3075 18.5 11.295 26.1719 8.60 376.0 57 43 26.0297 0 -99.0 0 -99.0 0 -99.00 0