*2024/07/31 10:35:08.83 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2012/06/04 16:33:00.000 END TIME : UTC 2012/06/04 16:33:00.833 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 21 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 482CD9FA NUMBER OF CHANNELS : 17 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 789 809 2 Bottle_Number n/a 1 21 3 Bottle:Firing_Sequence n/a 1 21 4 Pressure decibar 2 601.5 5 Temperature:Secondary 'deg C (ITS90)' 3.6116 6.8615 6 Transmissivity %/metre 57.7 67.5 7 Fluorescence:URU:Seapoint mg/m^3 0.41E-01 0.843 8 Fluorescence:URU:Wetlabs mg/m^3 0.133 1.682 9 Salinity:T1:C1 PSS-78 32.6915 34.2141 10 Oxygen:Dissolved:SBE mL/L 0.66 7.18 11 Oxygen:Dissolved:SBE umol/kg 28.7 312.3 12 Number_of_bin_records n/a 50 241 13 Cesium-134 Bq/m3 0 0.24 14 Cesium-134:Uncertainty Bq/m3 0.5E-01 0.11 15 Cesium-137 Bq/m3 0.39 1.79 16 Cesium-137:Uncertainty Bq/m3 0.9E-01 0.17 17 Flag:Cs n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F R4 1 7 -99 ' ' 8 F R4 3 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' 9 F ' ' 4 10 -99 ' ' 7 F ' ' 2 11 -99 ' ' 6 F ' ' 1 12 ' ' ' ' 5 I I 0 13 -99 ' ' 7 F R4 2 14 -99 ' ' 7 F R4 2 15 -99 ' ' 7 F R4 2 16 -99 ' ' 7 F R4 2 17 -99 ' ' 3 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2012-12 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : TRAP-R EVENT NUMBER : 102 LATITUDE : 49 55.16000 N ! (deg min) LONGITUDE : 144 34.19000 W ! (deg min) WATER DEPTH : 4134 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 LOCATION : Mid-ship ! custom item $REMARKS SOFTWARE VERSION SEASAVE V 7.21B $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1.2 2012/08/15 12:08:06 3913 3913 CLEAN 5.0.4 2012/08/15 12:09:01 3913 3913 ADDSAMP 3.5 2012/08/15 12:55:34 3913 3913 BINAVE 4.1.1 2012/08/17 08:46:00 3913 21 MERGE 3.4 2012/08/17 08:46:05 21 21 CLEAN 5.0.4 2012/08/17 08:46:11 21 21 CALIB 11.7 2012/08/29 13:21:08 21 21 SORT 3.5 2012/08/29 13:21:22 21 21 REMOVECH 8.1.1 2012/08/29 13:22:08 21 21 CHGUNITS 3.0 2012/08/29 13:22:58 21 21 CHGUNITS 3.0 2012/08/29 13:23:18 21 21 REORDER 1.3 2012/08/29 13:23:35 ? ? HDREDIT2 2.5.1 2012/10/05 10:28:49 ? ? MERGE 3.4 2012/10/09 15:20:30 21 21 REORDER 1.3 2012/10/09 15:20:45 ? ? SORT 3.5 2012/11/19 15:52:26 21 21 REMOVECH 8.1.1 2012/11/19 15:55:02 21 21 MERGE 3.4 2012/11/19 16:27:27 21 21 REORDER 1.3 2012/11/19 16:30:04 ? ? SORT 3.5 2012/11/19 16:30:08 21 21 CALIB 11.7 2013/06/04 13:17:53 21 21 HDREDIT2 2.6 2013/07/08 08:52:08 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:37:28 21 21 HDREDIT2 3.2 2020/01/22 11:47:57 ? ? SORT 3.6 2024/07/23 11:43:20 21 21 MERGE 3.6 2024/07/23 11:43:44 21 21 SORT 3.6 2024/07/25 14:17:47 21 21 CLEAN 5.3 2024/07/31 10:34:30 21 21 HDREDIT2 3.2 2024/07/31 10:35:08 ? ? $END $REMARKS -CLEAN functions: 2012/08/15 12:08:12 20 Interpolation by Channel 1: Scan_Number [n/a] in Pressure Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2012-12\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2012/08/17 08:46:01 2012/08/17 08:46:02 2012/08/17 08:46: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Event_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2012-12\processing\hydro\2012-12-0102.samavg Secondary file: P:\Cruise_Data_Processing\2012-12\processing\hydro\2012-12-0102.mrgcln1s -SORT parameters: 2012/08/16 07:53:49 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2012/08/17 08:46:09 20 Reset #RECS, MIN & MAX values in header. Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2012/08/29 13:21:08 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2012-12\Processing\doc\2012-12-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 17 Salinity:T1:C1 PSS-78 10 0.1700000E-02 0.1000000E+01 -SORT parameters: 2012/08/29 13:21:22 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2012/08/29 13:22:08 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] PAR [uE/m^2/sec] Altimeter [metres] Status:Pump Descent_Rate [m/s] Salinity:T0:C0 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: - No units changed -HEADER EDITS: 2012/10/05 10:28:49 Applied edit header: P:\Cruise_Data_Processing\2012-12\Processing\doc\HYDRO\2012-12-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 6: Fluorescence:URU:Wetlabs [mg/m^3] Name: Fluorescence:Wetlabs:ECO-AFL ==> Fluorescence:URU:Wetlabs Channel 7: Salinity:Practical:T1:C1 [PSS-78] Name: Salinity:T1:C1 ==> Salinity:Practical:T1:C1 Channel 8: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Format: F5.1 ==> F8.3 -The following MERGE parameters were used: 2012/10/09 15:20:28 2012/10/09 15:20:28 2012/10/09 15:20: Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Transmissivity [%/metre] Primary file : P:\Cruise_Data_Processing\2012-12\Processing\fix\2012-12-0102.che1 Secondary file: P:\Cruise_Data_Processing\2012-12\Processing\fix\2012-12-0102.cln2 -SORT parameters: 2012/11/19 15:52:26 Sorted in ascending order of channel Bottle_Number -REMOVECH 2012/11/19 15:55:02 The following CHANNEL(S) were removed: Transmissivity [%/metre] Fluorescence:URU:Seapoint [mg/m^3] -The following MERGE parameters were used: 2012/11/19 16:27:25 2012/11/19 16:27:25 2012/11/19 16:27: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Transmissivity, Fluorescence:URU:Seapoint Primary file : P:\Cruise_Data_Processing\2012-12\Processing\fix\2012-12-0102.mrgrem Secondary file: P:\Cruise_Data_Processing\2012-12\Processing\fix\2012-12-0102.fltr -SORT parameters: 2012/11/19 16:30:08 Sorted in ascending order of channel Pressure -CALIB parameters: 2013/06/04 13:17:53 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\Nutrients\doc\Nutrients-recal1.ccf WARNING: No calibration done on file C:\Data\Nutrients\2012-12\2012-12-0102.cor1 -HEADER EDITS: 2013/07/08 08:52:08 Applied edit header: C:\DATA\Nutrients\doc\headedit-correction.txt -HEADER EDITS: 2020/01/22 11:47:57 - none. -SORT parameters: 2024/07/23 11:43:20 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2024/07/23 11:43:44 Merge Channel: Sample_Number Merge Scheme Used: 4: Add Secondary to Matching Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Cesium-134, Cesium-134:Uncertainty, Cesium-137, Cesium-137:Uncertainty, Flag:Cs Primary file : C:\Users\huntingtons\Desktop\Cesium_additions\2012-012\Processing\IOS\2012-012- 0102.chesort Secondary file: C:\Users\huntingtons\Desktop\Cesium_additions\2012-012\Processing\IOS\2012-012- 0102.csm 20 secondary records matched to primary records. -SORT parameters: 2024/07/25 14:17:47 Sorted in ascending order of channel Pressure -CLEAN functions: 2024/07/31 10:34:30 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag* Set header Start and End times from the data. -HEADER EDITS: 2024/07/31 10:35:08 Applied edit header: C:\Users\huntingtons\Desktop\Additions\Cesium_additions\2012-012\Processing\ DOC\2012-012-hdr.txt Channel 17: Flag:Cs [n/a] Units: ==> n/a Pad: 0 ==> -99 $END *COMMENTS Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -20C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours and analyzed on a Turner 10AU fluorometer which is calibrated annually with commercially pure chlorophyll a (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed on board ship in a controlled temperature lab. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). For details see worksheet “CV%” in file QF2012-12_CHL-*.xls. Phaeopigment data are provided for information only and no quality flags are assigned to them. Oxygen samples were analyzed at sea on an automated Winkler titration system (Brinkmann Dosimat model 765 and a PC950 Colorimeter controlled by AutoOxy software V3.4) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). For details including a duplicate analysis, see document QF2012-12oxy*.xls. Salinity samples were collected in 200 mL type ll glass bottles with reusable silicone inserts supplied by Xiamen Cuten Accessories Industry Limited and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater within 2 months after collection. Full details including a duplicate analysis are in file QF2012-12sal*.xls. Nutrient samples were collected in plastic tubes and analyzed at sea, except for the repeated P4 inbound samples. The repeated P4 inbound samples were frozen, or in the case of deep Silicate stored cool, and analyzed at IOs. All samples were analyzed using an Astoria analyzer following methods described in Barwell-Clarke and Whitney (1996). File QF2012-12nuts*.xls includes the raw data and a precision study. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2012-12 DMS Report.doc and for data see DMS 2012-12-DMS*.xls. Cesium Analysis: Large volume (~50 L) water samples were collected and then passed through potassium cobalt ferrocyanide (KCFC) resin columns to selectively extract Cs isotopes from seawater. Column extraction efficiencies are generally greater than 96% as determined using spiked yield tracers with resin columns arranged in series. The isotopes 137Cs and 134Cs were subsequently measured on the oven-dried KCFC resins in the laboratory using high purity Ge well detectors. All data were decay-corrected to the time of sampling. A second level of analysis was often undertaken by subsequently decay correcting the data to April 6 2011 which was the time of maximum discharges from Fukushima. Detection limits (DL) for 137Cs and 134Cs were generally 0.10 Bq/m3 and 0.13 Bq/m3 respectively so "0" values should be interpreted as < detection limit. Detector efficiencies were measured using National Institute of Standards and Technology (NIST) and National Bureau of Sciences (NBS) calibration standards (e.g., NBS 4350B river sediment) and IAEA reference materials All the CTD variables are averaged over the same pressures in order to have one line of data per sample, even if the sample came from multiple casts. The lowest sample number was used to represent a sample. Sample_Number 789: Cesium: 60-litre sample; 50 litres sampled on cast 99. Sample_Number 791: Cesium: 60-litre sample; 50 litres sampled on cast 99. Sample_Number 792: Cesium: 60-litre sample; 50 litres sampled on cast 99. Sample_Number 794: Cesium: 60-litre sample; 50 litres sampled on cast 99. Sample_Number 796: Cesium: 60-litre sample; 30 litres sampled on cast 99 and 20 litres sampled on cast 100 Sample_Number 798: Cesium: 60-litre sample; 50 litres sampled on cast 100. Sample_Number 800: Cesium: 60-litre sample; 50 litres sampled on cast 100. Sample_Number 803: Cesium: 60-litre sample; 50 litres sampled on cast 100. Sample_Number 808: Cesium: 60-litre sample; 50 litres sampled on cast 100. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Data Processing Notes: ---------------------- Transmissivity, fluorescence and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". SBE DO calibration was done using the method described in the SeaBird Application NOte #64-2. For further processing details see the processing report 2012-12-proc.doc. July 2013: A correction has been applied to Nitrate_plus_Nitrite and Phosphate data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the following report: Corrections to Nitrate and Phosphate for Deep-Water Cruises from 2009 to 2012.pdf which is stored in folder: \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Comments from secondary file: C:\Users\huntingtons\Desktop\Cesium_additions\2012-012\Processing\IOS\2012-012-0102.csm --------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T1:C1 PSS-78 10 -99 () (0.17E-02 1) $END !-1-- 2- 3- --4--- ---5---- --6-- ---7--- ---8--- ---9---- --10-- --11- -12- --13-- --14-- --15-- --16-- 17 !Samp Bo Bo Pressu Temperat Trans Fluores Fluores Salinity Oxygen Oxyge Numb Cesium Cesium Cesium Cesium Fl !le_ tt tt re ure: missi cence: cence: :T1:C1 : n: er_o -134 -134: -137 -137: ag !Numb ~u ~u Secondar vity URU: URU: Dissol Disso ~bin Uncert Uncert : !er mb en y Seapoin Wetlabs ved: lved: _rec ainty ainty Cs ! er ce t SBE SBE ords !---- -- -- ------ -------- ----- ------- ------- -------- ------ ----- ---- ------ ------ ------ ------ -- *END OF HEADER 807 19 20 2.0 6.8615 58.9 0.425 0.551 32.7017 7.09 308.7 50 -99.00 -99.00 -99.00 -99.00 0 808 20 21 2.4 6.6339 57.7 0.620 1.179 32.6915 7.16 311.4 241 0.20 0.11 1.79 0.15 2 806 18 19 11.1 6.8530 59.7 0.536 0.844 32.7018 7.09 308.7 241 -99.00 -99.00 -99.00 -99.00 0 805 17 18 21.2 6.7882 59.7 0.786 1.102 32.7031 7.09 308.6 241 -99.00 -99.00 -99.00 -99.00 0 804 16 17 31.4 6.5798 60.5 0.843 1.588 32.7118 7.13 310.5 241 -99.00 -99.00 -99.00 -99.00 0 809 21 16 41.5 6.5584 58.9 0.227 1.682 32.7120 7.10 309.1 241 -99.00 -99.00 -99.00 -99.00 0 803 15 15 51.5 5.4718 63.6 0.570 1.144 32.7179 7.18 312.3 241 0.24 0.09 1.59 0.14 2 802 14 14 50.4 6.4354 61.5 0.792 1.559 32.7110 7.10 308.9 147 -99.00 -99.00 -99.00 -99.00 0 801 13 13 75.9 5.4216 64.6 0.474 0.950 32.7190 7.14 310.9 241 -99.00 -99.00 -99.00 -99.00 0 799 11 11 101.4 5.0205 66.5 0.132 0.310 32.7734 6.95 302.5 79 -99.00 -99.00 -99.00 -99.00 0 800 12 12 101.4 4.0984 67.1 0.100 0.218 32.8209 7.02 305.5 241 0.13 0.05 1.30 0.11 2 797 9 9 150.9 4.6034 67.0 0.041 0.133 33.6487 4.22 183.7 89 -99.00 -99.00 -99.00 -99.00 0 798 10 10 151.6 4.4510 67.0 0.047 0.136 33.6323 4.16 180.9 241 0.00 -99.00 1.15 0.15 2 795 7 7 202.0 4.1583 67.2 0.043 0.147 33.7580 2.98 129.4 51 -99.00 -99.00 -99.00 -99.00 0 796 8 8 202.1 4.0018 67.2 0.045 0.139 33.7467 2.85 123.8 241 0.00 -99.00 0.85 0.17 2 793 5 5 301.2 3.8134 67.1 0.046 0.141 33.8885 1.61 69.8 66 -99.00 -99.00 -99.00 -99.00 0 794 6 6 301.2 3.8404 67.0 0.048 0.145 33.8878 1.67 72.6 241 0.00 -99.00 0.77 0.11 2 792 4 4 401.3 3.8422 67.2 0.048 0.148 34.0159 1.17 50.8 241 0.00 -99.00 0.68 0.12 2 790 2 2 501.1 3.7783 67.4 0.047 0.148 34.1186 0.77 33.6 57 -99.00 -99.00 -99.00 -99.00 0 791 3 3 501.4 3.7740 67.5 0.048 0.142 34.1314 0.80 35.0 241 0.00 -99.00 0.39 0.09 2 789 1 1 601.5 3.6116 67.5 0.048 0.146 34.2141 0.66 28.7 241 0.00 -99.00 0.47 0.09 2