*2013/12/16 15:37:01.63 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2012/02/09 23:59:35.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 24 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 208252BF NUMBER OF CHANNELS : 11 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- -------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 24 2 Bottle:Firing_Sequence n/a 1 24 3 Pressure decibar 4.5 500.1 4 Temperature:Primary 'deg C (ITS90)' 5.1916 8.278 5 Transmissivity %/metre 60.9 67.4 6 Fluorescence:URU:Wetlabs mg/m^3 0.383 1.404 7 Salinity:T0:C0 PSS-78 32.4179 34.1112 8 Oxygen:Dissolved:SBE mL/L 0.66 6.59 9 Oxygen:Dissolved:SBE umol/kg 28.5 287 10 Number_of_bin_records n/a 50 241 11 Sample_Number n/a 58 81 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 3 I I 0 3 -99 ' ' 7 F ' ' 1 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 7 F ' ' 2 9 -99 ' ' 6 F ' ' 1 10 ' ' ' ' 5 I I 0 11 -99 ' ' 5 I I 0 $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2012-01 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P4 EVENT NUMBER : 6 LATITUDE : 48 39.02000 N ! (deg min) LONGITUDE : 126 39.97000 W ! (deg min) WATER DEPTH : 1322 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 LOCATION : Mid-ship ! custom item $REMARKS SOFTWARE VERSION SEASAVE V 7.21B $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2012/04/04 10:54:49 4246 4246 CLEAN 5.0.4 2012/04/04 10:55:25 ? ? ADDSAMP 3.5 2012/04/04 15:31:08 4246 4246 BINAVE 4.1.1 2012/04/04 15:32:19 4246 24 MERGE 3.4 2012/04/18 14:12:39 24 24 CLEAN 5.0.4 2012/04/18 14:38:13 ? ? CALIB 11.7 2012/04/18 14:39:06 24 24 SORT 3.5 2012/04/18 14:39:10 24 24 REMOVECH 8.1.1 2012/04/18 14:39:30 24 24 CHGUNITS 3.0 2012/04/18 14:40:33 24 24 CHGUNITS 3.0 2012/04/18 14:40:47 24 24 REORDER 1.3 2012/04/18 14:41:13 ? ? CALIB 11.7 2012/04/18 14:41:30 24 24 HDREDIT2 2.5.1 2012/04/26 13:02:22 ? ? CALIB 11.7 2013/06/04 13:17:25 24 24 HDREDIT2 2.6 2013/07/08 08:51:55 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:37:01 24 24 $END $REMARKS -CLEAN functions: 2012/04/04 10:55:21 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2012-01\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2012/04/18 14:12:39 2012/04/18 14:12:39 2012/04/18 14:12: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Event_Number, Bottle:Position, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2012-01\Processing\hydro\2012-01-0006.samavg Secondary file: P:\Cruise_Data_Processing\2012-01\Processing\hydro\2012-01-0006.mrgcln1s -SORT parameters: 2012/04/18 14:11:51 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2012/04/18 14:38:13 20 Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2012/04/18 14:39:05 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2012-01\Processing\doc\2012-01-recal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 0.2200000E-01 0.1000000E+01 -SORT parameters: 2012/04/18 14:39:10 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2012/04/18 14:39:30 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Status:Pump Descent_Rate [m/s] Salinity:T1:C1 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: - No units changed -CALIB parameters: 2012/04/18 14:41:30 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2012-01\Processing\doc\2012-01-recal2.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 6 Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 0.0000000E+00 0.4166700E+01 -HEADER EDITS: 2012/04/26 13:02:22 Applied edit header: P:\Cruise_Data_Processing\2012-01\Processing\doc\2012-01-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 6: Fluorescence:URU:Wetlabs [mg/m^3] Name: Fluorescence:Wetlabs:ECO-AFL ==> Fluorescence:URU:Wetlabs Channel 8: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 7: Salinity:Practical:T0:C0 [PSS-78] Name: Salinity:T0:C0 ==> Salinity:Practical:T0:C0 -CALIB parameters: 2013/06/04 13:17:25 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\Nutrients\doc\Nutrients-recal1.ccf WARNING: No calibration done on file C:\Data\Nutrients\2012-01\2012-01-0006.cor1 -HEADER EDITS: 2013/07/08 08:51:55 Applied edit header: C:\DATA\Nutrients\doc\headedit-correction.txt $END *COMMENTS Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -20C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours in the temperature-controlled lab onboard ship and analyzed on a Turner 10AU fluorometer which is calibrated annually with commercially pure chlorophyll a (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed on board ship in a controlled temperature lab. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). For details see worksheet “CV%” in file QF2012-01_CHL-*.xls. Phaeopigment data are provided for information only and no quality flags are assigned to them. Oxygen samples were analyzed on an automated Winkler titration system (Brinkmann Dosimat model 765 and a PC950 Colorimeter controlled by AutoOxy software V3.4) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). All samples were analyzed at sea. For details including a duplicate analysis, see document QF2012-01oxy*.xls. Salinity samples were collected in 200 mL type ll glass bottles with reusable silicone inserts supplied by Xiamen Cuten Accessories Industry Limited and screw caps supplied by Ocean Scientific International Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater within 9-11 days after the end of the cruise. For details including a duplicate analysis see file QF2012-01sal*.xls. Nutrient samples were collected in plastic tubes and quick frozen in aluminum blocks stored in -20C freezer. Another set of samples from 400m and deeper (to be used for silicate analysis) is collected and stored at 4C in the dark. All samples were later analyzed at IOS using the Astoria analyzer following methods described in Barwell-Clarke and Whitney (1996). File "QF2012-01nuts*.xls" includes the raw data and a precision study. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Data Processing Notes: ---------------------- Transmissivity and PAR data are nominal and unedited except that some records were removed in editing temperature and salinity. Fluorescence data were recalibrated to correct an error in the scale factor used in the original conversion. The data are still considered nominal and are unedited. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". SBE DO calibration was done using the method described in the SeaBird Application NOte #64-2. For further processing details see the processing report 2012-01-proc.doc. July 2013: A correction has been applied to Nitrate_plus_Nitrite and Phosphate data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the following report: Corrections to Nitrate and Phosphate for Deep-Water Cruises from 2009 to 2012.pdf which is stored in folder: \\Cruise_Data\DOCUMENTS\Analysis Reference Papers *CALIBRATION $TABLE: CORRECTED CHANNELS !Name Units Fmla Pad Coefficients !------------------------------ -------- ---- ------ ------------ Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 -99 () (0.22E-01 1) Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 -99 () (0 4.1667) $END !1- 2- --3--- ---4---- --5-- ---6--- ---7---- --8--- --9-- -10- -11- !Bo Bo Pressu Temperat Trans Fluores Salinity Oxygen Oxyge Numb Samp !tt tt re ure: missi cence: :T0:C0 : n: er_o le_ !~u ~u Primary vity URU: Dissol Disso ~bin Numb !mb en Wetlabs ved: lved: _rec er !er ce SBE SBE ords !-- -- ------ -------- ----- ------- -------- ------ ----- ---- ---- *END OF HEADER 22 24 4.5 8.2770 60.9 1.333 32.4179 6.59 286.7 241 79 20 22 10.6 8.2780 60.9 1.404 32.4350 6.59 286.8 146 77 21 23 11.1 8.2778 60.9 1.383 32.4353 6.59 287.0 241 78 19 21 20.3 8.2748 61.1 1.367 32.4396 6.59 286.9 241 76 18 20 21.4 8.2749 61.0 1.371 32.4397 6.59 286.9 51 75 17 19 29.4 8.2673 61.3 1.296 32.4465 6.58 286.7 241 74 16 18 30.4 8.2667 61.3 1.308 32.4471 6.58 286.5 50 73 24 17 39.7 8.2566 61.5 1.233 32.4557 6.57 286.0 241 81 15 16 50.7 8.2456 61.7 1.200 32.4639 6.55 285.4 241 72 14 15 51.4 8.2461 61.7 1.138 32.4636 6.56 285.6 61 71 12 13 75.7 8.1699 63.3 0.588 32.6783 5.67 247.0 53 69 13 14 75.9 8.1721 63.5 0.600 32.6808 5.74 249.9 241 70 11 12 98.6 8.0360 63.3 0.438 33.3001 3.92 170.7 241 68 10 11 98.9 8.0333 63.4 0.442 33.3025 3.92 170.6 219 67 23 10 124.9 7.7680 66.4 0.392 33.5386 3.54 153.9 241 80 9 9 150.2 7.6216 66.3 0.392 33.6931 3.15 137.0 241 66 8 8 150.8 7.6226 66.3 0.396 33.6955 3.16 137.3 58 65 6 6 200.4 7.3002 66.5 0.383 33.8479 2.73 118.9 68 63 7 7 201.3 7.2817 66.5 0.392 33.8543 2.71 117.8 241 64 4 4 299.1 6.2791 67.2 0.400 33.9362 2.07 90.0 102 61 5 5 299.3 6.2822 67.1 0.396 33.9360 2.07 90.1 241 62 3 3 400.6 5.7396 67.2 0.388 34.0333 1.12 48.5 241 60 2 2 500.0 5.1920 67.4 0.383 34.1110 0.66 28.5 241 59 1 1 500.1 5.1916 67.3 0.400 34.1112 0.66 28.5 64 58