*2021/11/25 11:10:31.99 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2011/09/04 14:37:38.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 25981AD0 NUMBER OF CHANNELS : 54 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 179 186 2 Bottle_Number n/a 1 8 3 Bottle:Firing_Sequence n/a 1 8 4 Pressure decibar 2.2 87.2 5 Temperature:Secondary 'deg C (ITS90)' 8.0213 14.1076 6 Transmissivity %/metre 3.7 57.8 7 Fluorescence:URU:Wetlabs mg/m^3 0.264 41.241 8 Salinity:T1:C1 PSS-78 30.3001 33.0528 9 Oxygen:Dissolved:SBE mL/L 2.77 8.85 10 Oxygen:Dissolved:SBE umol/kg 120.6 386.6 11 Number_of_bin_records n/a 241 241 12 Temperature:Draw 'deg C (ITS90)' 8.3 12.5 13 Salinity:Bottle PSS-78 30.6517 30.6517 14 Flag:Salinity:Bottle n/a 15 Oxygen:Dissolved mL/L 2.741 5.991 16 Oxygen:Dissolved umol/kg 119.3 261.4 17 Flag:Oxygen:Dissolved n/a 18 Nitrate_plus_Nitrite umol/L 7.5 30.8 19 Flag:Nitrate_plus_Nitrite n/a 20 Silicate umol/L 28.4 46.7 21 Flag:Silicate n/a 22 Phosphate umol/L 1.07 2.41 23 Flag:Phosphate n/a 24 Ammonium umol/L 0.4E-01 1.87 25 Flag:Ammonium n/a 26 Chlorophyll:Extracted mg/m^3 1.37 29.63 27 Flag:Chlorophyll:Extracted n/a 28 Phaeo-Pigment:Extracted mg/m^3 0.85 2.11 29 HPLC:Chl-c3 mg/m^3 0.15E-01 0.288 30 HPLC:Chlide-a mg/m^3 0.3E-01 0.452 31 HPLC:MgDVP mg/m^3 0.7E-02 0.682 32 HPLC:Chl-c2 mg/m^3 0.114 9.473 33 HPLC:Chl-c1 mg/m^3 0.28E-01 0.255 34 HPLC:Me-chlide mg/m^3 0.36E-01 0.637 35 HPLC:Peri mg/m^3 0.65E-01 39.601 36 HPLC:Pheide-a mg/m^3 0 0.438 37 HPLC:But-fuco mg/m^3 0.21E-01 0.254 38 HPLC:Fuco mg/m^3 0.459 2.444 39 HPLC:Neo mg/m^3 0 0.1E-01 40 HPLC:Pras mg/m^3 0 0 41 HPLC:Viola mg/m^3 0.2E-02 0.125 42 HPLC:Hex-fuco mg/m^3 0 0.281 43 HPLC:Diadino mg/m^3 0.3E-01 5.898 44 HPLC:Allo mg/m^3 0.13E-01 0.296 45 HPLC:Diato mg/m^3 0.3E-02 0.388 46 HPLC:Zea mg/m^3 0.7E-02 0.76E-01 47 HPLC:Lut mg/m^3 0 0.19E-01 48 HPLC:Chl-b mg/m^3 0.1E-01 0.186 49 HPLC:DVChl-a mg/m^3 0 0.11E-01 50 HPLC:Chl-a mg/m^3 0.691 31.535 51 HPLC:Phe mg/m^3 0 0.884 52 HPLC:B-Car mg/m^3 0.15E-01 0.23 53 HPLC:TChl-a mg/m^3 0.758 32.625 54 Flag:HPLC ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 5 I I 0 3 -99 ' ' 5 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 8 F ' ' 3 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 5 I I 0 12 -99 ' ' 6 F R4 1 13 -99 ' ' 9 F R4 4 14 -99 ' ' 3 NQ C ' ' 15 -99 ' ' 8 F R4 3 16 -99 ' ' 6 F ' ' 1 17 -99 ' ' 3 NQ C ' ' 18 -99 ' ' 6 F R4 1 19 -99 ' ' 3 NQ C ' ' 20 -99 ' ' 6 F R4 1 21 -99 ' ' 3 NQ C ' ' 22 -99 ' ' 7 F R4 2 23 -99 ' ' 3 NQ C ' ' 24 -99 ' ' 7 F R4 2 25 -99 ' ' 3 NQ C ' ' 26 -99 ' ' 7 F R4 2 27 -99 ' ' 3 NQ C ' ' 28 -99 ' ' 7 F R4 2 29 -99 ' ' 8 F R4 3 30 -99 ' ' 8 F R4 3 31 -99 ' ' 8 F R4 3 32 -99 ' ' 8 F R4 3 33 -99 ' ' 8 F R4 3 34 -99 ' ' 8 F R4 3 35 -99 ' ' 8 F R4 3 36 -99 ' ' 8 F R4 3 37 -99 ' ' 8 F R4 3 38 -99 ' ' 8 F R4 3 39 -99 ' ' 8 F R4 3 40 -99 ' ' 8 F R4 3 41 -99 ' ' 8 F R4 3 42 -99 ' ' 8 F R4 3 43 -99 ' ' 8 F R4 3 44 -99 ' ' 8 F R4 3 45 -99 ' ' 8 F R4 3 46 -99 ' ' 8 F R4 3 47 -99 ' ' 8 F R4 3 48 -99 ' ' 8 F R4 3 49 -99 ' ' 8 F R4 3 50 -99 ' ' 8 F R4 3 51 -99 ' ' 8 F R4 3 52 -99 ' ' 8 F R4 3 53 -99 ' ' 8 F R4 3 54 -99 ' ' 3 NQ C ' ' $END $REMARKS This file converted from Sea-Bird file: P:\Cruise_Data_Processing\2011-17\Pro REPLACE Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2011-17 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : La Perouse - WCVI SCIENTIST : Yelland D. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI STATION : LC01 EVENT NUMBER : 50 LATITUDE : 48 50.44000 N ! (deg min) LONGITUDE : 125 27.73000 W ! (deg min) WATER DEPTH : 97 ALTIMETER (M) : 9.01 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 LOCATION : Mid-ship ! custom item $REMARKS SOFTWARE VERSION SEASAVE V 7.21B $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2012/02/16 10:26:00 1928 1928 CLEAN 5.0.4 2012/02/16 10:26:43 ? ? ADDSAMP 3.5 2012/02/16 10:46:22 1928 1928 BINAVE 4.1.1 2012/02/16 10:47:09 1928 8 MERGE 3.4 2012/02/21 15:44:07 8 8 CLEAN 5.0.4 2012/02/21 15:44:12 8 8 CALIB 11.7 2012/02/27 11:25:45 8 8 SORT 3.5 2012/02/27 11:56:48 8 8 REMOVECH 8.1.1 2012/02/27 12:01:40 8 8 CHGUNITS 3.0 2012/02/27 12:02:27 8 8 CHGUNITS 3.0 2012/02/27 12:02:49 8 8 REORDER 1.3 2012/02/27 12:09:48 ? ? HDREDIT2 2.5.1 2012/02/28 10:35:50 ? ? CALIB 11.7 2013/06/04 13:16:12 8 8 HDREDIT2 2.6 2013/07/08 08:51:18 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:35:58 8 8 CHANGE_FLAGS 2.0 2014/11/20 09:57:40 8 8 SORT 3.6 2020/08/23 14:46:33 8 8 REORDER 1.3.1 2021/11/25 11:09:16 ? ? MERGE 3.5.1 2021/11/25 11:09:28 8 8 SORT 3.6 2021/11/25 11:09:37 8 8 CLEAN 5.2.4 2021/11/25 11:09:48 8 8 HDREDIT2 3.2 2021/11/25 11:10:12 ? ? HDREDIT2 3.2 2021/11/25 11:10:31 ? ? $END $REMARKS -CLEAN functions: 2012/02/16 10:26:28 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: P:\Cruise_Data_Processing\2011-17\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2012/02/21 15:44:06 2012/02/21 15:44:06 2012/02/21 15:44: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Event_Number, Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Temperature:Draw, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : P:\Cruise_Data_Processing\2011-17\Processing\hydro\2011-17-0050.samavg Secondary file: P:\Cruise_Data_Processing\2011-17\Processing\hydro\2011-17-0050.mrgcln1s Comments from secondary file: P:\Cruise_Data_Processing\2011-17\Processing\hydro\2011-17-0050.mrgcln1s ------------------------------------------------------------------------ -CLEAN functions: 2012/02/16 12:49:37 20 Reduce header to sections: FIL ADM LOC DEP REC INS HIS RAW CAL COM Remarks removed from kept sections. -SORT parameters: 2012/02/16 12:49:41 Sorted in ascending order of channel Bottle_Number -CLEAN functions: 2012/02/21 15:44:11 20 Reset #RECS, MIN & MAX values in header. Remove Sea-Bird comments from the header. -CALIB parameters: 2012/02/27 11:25:45 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = P:\Cruise_Data_Processing\2011-17\Processing\doc\2011-17-recal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 0.9100000E-01 0.1000000E+01 -SORT parameters: 2012/02/27 11:56:48 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2012/02/27 12:01:40 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] PAR [uE/m^2/sec] Altimeter [metres] Status:Pump Descent_Rate [m/s] Salinity:T0:C0 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -CHANGE units: 'Oxygen:Dissolved' changed from mL/L to umol/kg -HEADER EDITS: 2012/02/28 10:35:50 Applied edit header: P:\Cruise_Data_Processing\2011-17\Processing\doc\2011-17-bot-hdr.txt Channel 2: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 1: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 3: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 6: Fluorescence:URU:Wetlabs [mg/m^3] Name: Fluorescence:Wetlabs:ECO-AFL ==> Fluorescence:URU:Wetlabs Channel 7: Salinity:Practical:T1:C1 [PSS-78] Name: Salinity:T1:C1 ==> Salinity:Practical:T1:C1 Channel 8: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 9: Oxygen:Dissolved:SBE [umol/kg] Format: F6.2 ==> F6.1 Channel 12: Temperature:Draw [deg C (ITS90)] Units: ==> deg C (ITS90) Channel 18: Oxygen:Dissolved [mL/L] Units: ==> mL/L Channel 19: Oxygen:Dissolved [umol/kg] Format: F6.2 ==> F6.1 Channel 21: Nitrate_plus_Nitrite [umol/L] Units: ==> umol/L Channel 23: Silicate [umol/L] Units: ==> umol/L Format: F7.2 ==> F6.1 Channel 25: Phosphate [umol/L] Units: ==> umol/L Channel 27: Ammonium [umol/L] Format: F8.4 ==> F7.2 -CALIB parameters: 2013/06/04 13:16:12 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\Nutrients\doc\Nutrients-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 21 Nitrate_plus_Nitrite umol/L 10 0.1709000E+00 0.9812000E+00 25 Phosphate umol/L 10 0.4530000E-01 0.1011500E+01 -HEADER EDITS: 2013/07/08 08:51:18 Applied edit header: C:\DATA\Nutrients\doc\headedit-correction.txt -SORT parameters: 2020/08/23 14:46:33 Sorted in ascending order of channel Sample_Number [n/a] -The following MERGE parameters were used: 2021/11/25 11:09:28 Merge Channel: sample_number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: HPLC:Chl-c3 [ ], HPLC:Chlide-a [ ], HPLC:MgDVP [ ], HPLC:Chl-c2 [ ], HPLC:Chl-c1 [ ], HPLC:Me-chlide [ ], HPLC:Peri [ ], HPLC:Pheide-a [ ], HPLC:But-fuco [ ], HPLC:Fuco [ ], HPLC:Neo [ ], HPLC:Pras [ ], HPLC:Viola [ ], HPLC:Hex-fuco [ ], HPLC:Diadino [ ], HPLC:Allo [ ], HPLC:Diato [ ], HPLC:Zea [ ], HPLC:Lut [ ], HPLC:Chl-b [ ], HPLC:C2mgdg, HPLC:DVChl-a [ ], HPLC:Chl-a [ ], HPLC:Phe [ ], HPLC:B-Car [ ], HPLC:TChl-a [ ], Flag:HPLC [ ] Primary file : C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2011\2011-017_Nov2021\Processing\ IOS\2011-017-0050.che2 Secondary file: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2011\2011-017_Nov2021\Processing\ IOS\2011-017-0050.hplc -SORT parameters: 2021/11/25 11:09:37 Sorted in ascending order of channel Pressure [decibar] -CLEAN functions: 2021/11/25 11:09:47 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Change character data from " " to "0" in channels Flag:* -HEADER EDITS: 2021/11/25 11:10:12 Applied edit header: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2011\2011-017\2011-017-bot- hdr1.txt Channel 2: Bottle_Number [n/a] Format: I3 ==> I5 Channel 3: Bottle:Firing_Sequence [n/a] Format: I3 ==> I5 Channel 12: Temperature:Draw [deg C (ITS90)] Format: F5.1 ==> F6.1 Channel 29: HPLC:Chl-c3 [mg/m^3] Units: ==> mg/m^3 Channel 30: HPLC:Chlide-a [mg/m^3] Units: ==> mg/m^3 Channel 31: HPLC:MgDVP [mg/m^3] Units: ==> mg/m^3 Channel 32: HPLC:Chl-c2 [mg/m^3] Units: ==> mg/m^3 Channel 33: HPLC:Chl-c1 [mg/m^3] Units: ==> mg/m^3 Channel 34: HPLC:Me-chlide [mg/m^3] Units: ==> mg/m^3 Channel 35: HPLC:Peri [mg/m^3] Units: ==> mg/m^3 Channel 36: HPLC:Pheide-a [mg/m^3] Units: ==> mg/m^3 Channel 37: HPLC:But-fuco [mg/m^3] Units: ==> mg/m^3 Channel 38: HPLC:Fuco [mg/m^3] Units: ==> mg/m^3 Channel 39: HPLC:Neo [mg/m^3] Units: ==> mg/m^3 Channel 40: HPLC:Pras [mg/m^3] Units: ==> mg/m^3 Channel 41: HPLC:Viola [mg/m^3] Units: ==> mg/m^3 Channel 42: HPLC:Hex-fuco [mg/m^3] Units: ==> mg/m^3 Channel 43: HPLC:Diadino [mg/m^3] Units: ==> mg/m^3 Channel 44: HPLC:Allo [mg/m^3] Units: ==> mg/m^3 Channel 45: HPLC:Diato [mg/m^3] Units: ==> mg/m^3 Channel 46: HPLC:Zea [mg/m^3] Units: ==> mg/m^3 Channel 47: HPLC:Lut [mg/m^3] Units: ==> mg/m^3 Channel 48: HPLC:Chl-b [mg/m^3] Units: ==> mg/m^3 Channel 49: HPLC:DVChl-a [mg/m^3] Units: ==> mg/m^3 Channel 50: HPLC:Chl-a [mg/m^3] Units: ==> mg/m^3 Channel 51: HPLC:Phe [mg/m^3] Units: ==> mg/m^3 Channel 52: HPLC:B-Car [mg/m^3] Units: ==> mg/m^3 Channel 53: HPLC:TChl-a [mg/m^3] Units: ==> mg/m^3 -HEADER EDITS: 2021/11/25 11:10:31 Applied edit header: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2011\2011-017\2011-017-bot- hdr2.txt $END *COMMENTS Comments from secondary file: P:\Cruise_Data_Processing\2011-17\Processing\hydro\2011-17-0050.mrgcln1s ------------------------------------------------------------------------ Comments from secondary file: P:\Cruise_Data_Processing\2011-17\Processing\hydro\2011-17-0050.chl ------------------------------------------------------------------- Sample_Number 185: CHL: variability of reps between 15-50 % Analysis methods: ----------------- Chlorophyll samples were filtered onto 25mm GF/F filters and stored in glass scintillation vials at -20C prior to analysis. Samples were extracted in 90% acetone at -20C for 24 hours and analyzed on a Turner 10AU fluorometer which is calibrated annually with commercially pure chlorophyll a (Sigma). Fluorescence readings taken before and after acidification were used to calculate chlorophyll and phaeopigment concentrations (Holm-Hansen et al 1965). Chlorophyll samples were analyzed on board ship in a controlled temperature lab. The average of two samples is reported. Variability is assessed as the CV% (std dev / mean*100). For details see worksheet “CV%” in file QF2011-17_CHL-*.xls. Phaeopigment data are provided for information only and no quality flags are assigned to them. HPLC samples were filtered onto 47mm GF/F filters and stored at -80C prior to analysis. Samples were extracted in 95% methanol at -20C for 24 hours in the lab and analyzed on a WATERS 2695 HPLC separations system as detailed in Nemcek and Pena, 2014. Analysis was performed ~5 months after collection. The average of two samples is reported. Variability is assessed as the %CV (std dev/mean*100) for duplicate pairs. All pigments below the limit of detection (LOD) are assigned a zero value. TChl-a is the sum of Chl-a, DVchl-a, Chlide-a and Me-chlide For further information see file QF 2011-017_HPLC*.xlsx. Oxygen samples were analyzed on an automated Winkler titration system (Brinkmann Dosimat model 765 and a PC950 Colorimeter controlled by AutoOxy software V3.4) with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). All samples were analyzed at sea. For details including a duplicate analysis, see document QF2011-17oxy*.xls. Salinity samples were collected in 200 mL type ll glass bottles with plastic inserts and screw caps supplied by Ocean Scientific Internation Limited. They were analyzed in a temperature-controlled lab on a Guildline 8400B Salinometer (S/N 68572) standardized with IAPSO standard seawater within 1 month of collection. after collection. Full details are in file QF2011-17sal*.xls. Nutrient samples were collected in plastic tubes. Most samples were analyzed cool or frozen at IOS. An Astoria analyzer was used following methods described in Barwell-Clarke and Whitney (1996). File "QF 2011-17nuts*.xls" includes the raw data and a precision study. Ammonia samples were analysed fresh at sea using a TD700 fluorometer. The ammonium method used at IOS is a simplification of the fluorometric technique of Holmes et al, 1999. This method applies to a wide range of ammonium concentrations, uses the addition of a single working reagent and reduces contamination. Typically, samples are collected during the day and stored in the cold room. The working reagent is added to standards and samples at the same time, and the fluorescence is read approximately 8 hours later using a calibrated TD 700 Fluorometer. For more information including details on precision see QF2011-17NH4.xls. References: 1. Barwell-Clarke, J. and Whitney, F. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 2. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 3. Culberson, C.H. 1991. Dissolved oxygen. WOCE Hydrographic Programme Operations and Methods (July 1991). 15pp. 4. Holm-Hansen, O., Lorenzen, C.J., Holmes, R.W., and Strickland J.D.H. 1965. Fluorometric Determination of Chlorophyll. J.du Cons. Intl. Pour l’Epl. De la Mer. 30:3-15. 5. Holmes, R.M., Aminot, A., Kerouel, R., Hooker, B.A., and Peterson, B.J. (1999). A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Can. J. Fish. Aquat. Sci., 56 1801-1808. 6. Nemcek, N. and Peña, M.A. 2014. Institute of Ocean Sciences Protocols for Phytoplankton Pigment Analysis by HPLC. Can. Tech. Rep. Fish. Aquat. Sci. 3117: x + 80 p. * For PDF versions of these papers see folder \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Data Processing Notes: ---------------------- Transmissivity, PAR and SBE Fluorescence data are nominal and unedited. For details on how the transmissivity calibration parameters were calculated see the document in folder "\cruise_data\documents\transmissivity". SBE DO calibration was done using the method described in the SeaBird Application NOte #64-2. For further processing details see the processing report 2011-17-proc.doc. July 2013: A correction has been applied to Nitrate_plus_Nitrite and Phosphate data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the following report: Corrections to Nitrate and Phosphate for Deep-Water Cruises from 2009 to 2012.pdf which is stored in folder: \\Cruise_Data\DOCUMENTS\Analysis Reference Papers Comments from secondary file: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2011\2011-017_Nov2021\Processing\IOS\2011-017-0050. hplc --------------------------------------------------------------------------- Sample_Number 184: HPLC: >10%CV for TChl-a Sample_Number 186: HPLC: >10%CV for TChl-a *CALIBRATION $TABLE: CORRECTED CHANNELS !Name Units Fmla Pad Coefficients !------------------------------ -------- ---- ------ ------------ Fluorescence:Wetlabs:ECO-AFL mg/m^3 10 -99 () (0.91E-01 1) Nitrate_plus_Nitrite umol/L 10 -99 () (0.1709 0.9812) Phosphate umol/L 10 -99 () (0.453E-01 1.0115) $END !-1-- -2-- -3-- --4--- ---5---- --6-- ---7--- ---8---- --9--- --10- -11- --12- ---13--- 14 ---15-- --16- 17 --18- 19 --20- 21 --22-- 23 --24-- 25 --26-- 27 --28-- ---29-- ---30-- ---31-- ---32-- ---33-- ---34-- ---35-- ---36-- ---37-- ---38-- ---39-- ---40-- ---41-- ---42-- ---43-- ---44-- ---45-- ---46-- ---47-- ---48-- ---49-- ---50-- ---51-- ---52-- ---53-- 54 !Samp Bott Bott Pressu Temperat Trans Fluores Salinity Oxygen Oxyge Numb Tempe Salinity Fl Oxygen: Oxyge Fl Nitra Fl Silic Fl Phosph Fl Ammoni Fl Chloro Fl Phaeo- HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC:B- HPLC: Fl !le_ le_ le:F re ure: missi cence: :T1:C1 : n: er_o ratur :Bottle ag Dissolv n: ag te_ ag ate ag ate ag um ag phyll: ag Pigmen Chl-c3 Chlide- MgDVP Chl-c2 Chl-c1 Me- Peri Pheide- But- Fuco Neo Pras Viola Hex- Diadino Allo Diato Zea Lut Chl-b DVChl-a Chl-a Phe Car TChl-a ag !Numb Numb ~ng_ Secondar vity URU: Dissol Disso ~bin e: ~o ed Disso ~o plus_ ~t ~i ~p ~o Extrac ~a t: a chlide a fuco fuco : !er er Sequ y Wetlabs ved: lved: _rec Draw tt lved lv Nitri ri ca ha ni ted ct Extrac HP ! ence SBE SBE ords le ed te te te te um ed ted LC !---- ---- ---- ------ -------- ----- ------- -------- ------ ----- ---- ----- -------- -- ------- ----- -- ----- -- ----- -- ------ -- ------ -- ------ -- ------ ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- -- *END OF HEADER 186 8 8 2.2 14.1076 3.7 41.241 30.3001 8.85 386.6 241 -99.0 -99.0000 0 -99.000 -99.0 0 -99.0 0 -99.0 0 -99.00 0 0.04 6 29.63 6 2.11 0.288 0.452 0.682 9.473 0.255 0.637 39.601 0.438 0.254 2.444 0.000 0.000 0.125 0.281 5.898 0.296 0.388 0.076 0.019 0.186 0.011 31.535 0.884 0.230 32.625 36 183 5 7 4.8 12.3281 31.0 8.603 30.6661 5.80 252.8 241 12.5 30.6517 0 5.991 261.4 0 7.5 0 28.4 0 1.07 0 -99.00 0 -99.00 0 -99.00 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 0 184 6 6 6.7 11.9292 42.9 3.797 30.7619 5.39 235.2 241 -99.0 -99.0000 0 -99.000 -99.0 0 -99.0 0 -99.0 0 -99.00 0 1.24 6 5.02 6 1.16 0.049 0.110 0.024 0.523 0.129 0.112 0.529 0.000 0.055 1.705 0.010 0.000 0.016 0.015 0.152 0.034 0.014 0.010 0.000 0.028 0.000 3.403 0.101 0.054 3.625 36 182 4 5 10.1 11.3985 51.1 2.181 30.9412 4.86 212.1 241 11.3 -99.0000 0 4.744 206.9 0 17.7 6 38.1 6 1.81 6 -99.00 0 -99.00 0 -99.00 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 0 185 7 4 17.0 10.5741 55.9 0.985 31.1666 4.22 184.1 241 -99.0 -99.0000 0 -99.000 -99.0 0 -99.0 0 -99.0 0 -99.00 0 1.87 6 1.37 36 0.85 0.015 0.030 0.007 0.114 0.028 0.036 0.065 0.196 0.021 0.459 0.000 0.000 0.002 0.000 0.030 0.013 0.003 0.007 0.000 0.010 0.000 0.691 0.000 0.015 0.758 6 181 3 3 24.9 9.5812 57.0 0.852 31.7023 3.57 155.4 241 9.7 -99.0000 0 3.536 154.1 6 27.2 0 45.1 0 2.20 0 -99.00 0 -99.00 0 -99.00 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 0 180 2 2 50.5 8.4404 57.8 0.283 32.5050 2.88 125.6 241 8.6 -99.0000 0 2.862 124.6 0 30.4 0 46.7 0 2.35 0 -99.00 0 -99.00 0 -99.00 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 0 179 1 1 87.2 8.0213 40.7 0.264 33.0528 2.77 120.6 241 8.3 -99.0000 0 2.741 119.3 0 30.8 0 46.5 0 2.41 0 -99.00 0 -99.00 0 -99.00 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 -99.000 0