*2021/11/24 16:35:43.39 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2010/06/18 10:39:38.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 2 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 6A2B0B0B NUMBER OF CHANNELS : 51 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------------------ --------------- -------------- -------------- 1 Sample_Number n/a 564 565 2 Bottle_Number n/a 2 3 3 Bottle:Firing_Sequence n/a 1 2 4 Pressure decibar 5.2 38.3 5 Temperature:Secondary 'deg C (ITS90)' 7.408 7.7892 6 Transmissivity %/metre 51 52.2 7 Fluorescence:URU:Seapoint mg/m^3 0.657 1.049 8 Salinity:T1:C1 PSS-78 32.5806 32.5885 9 Oxygen:Dissolved:SBE mL/L 6.68 6.75 10 Oxygen:Dissolved:SBE umol/kg 290.9 294 11 Number_of_bin_records n/a 121 121 12 Salinity:Bottle PSS-78 32.5898 32.5898 13 Flag:Salinity:Bottle n/a 14 Oxygen:Dissolved mL/L -99 -99 15 Flag:Oxygen:Dissolved n/a 16 Nitrate_plus_Nitrite umol/L 12.2 12.2 17 Flag:Nitrate_plus_Nitrite n/a 18 Silicate umol/L 18 18 19 Flag:Silicate n/a 20 Phosphate umol/L 1.17 1.17 21 Flag:Phosphate n/a 22 Chlorophyll:Extracted mg/m^3 0.36 0.52 23 Flag:Chlorophyll:Extracted n/a 24 Phaeo-Pigment:Extracted mg/m^3 0.6E-01 0.12 25 Flag:Phaeo-Pigment:Extracted n/a 26 HPLC:Chl-c3 mg/m^3 0.31E-01 0.91E-01 27 HPLC:Chlide-a mg/m^3 0 0 28 HPLC:MgDVP mg/m^3 0.4E-02 0.6E-02 29 HPLC:Chl-c2 mg/m^3 0.37E-01 0.78E-01 30 HPLC:Chl-c1 mg/m^3 0 0 31 HPLC:Me-chlide mg/m^3 0 0 32 HPLC:Peri mg/m^3 0 0 33 HPLC:Pheide-a mg/m^3 0 0 34 HPLC:But-fuco mg/m^3 0.32E-01 0.67E-01 35 HPLC:Fuco mg/m^3 0.51E-01 0.101 36 HPLC:Neo mg/m^3 0.2E-02 0.7E-02 37 HPLC:Pras mg/m^3 0.5E-02 0.6E-02 38 HPLC:Viola mg/m^3 0.7E-02 0.8E-02 39 HPLC:Hex-fuco mg/m^3 0.104 0.211 40 HPLC:Diadino mg/m^3 0.24E-01 0.44E-01 41 HPLC:Allo mg/m^3 0 0.2E-02 42 HPLC:Diato mg/m^3 0.4E-02 0.4E-02 43 HPLC:Zea mg/m^3 0.18E-01 0.25E-01 44 HPLC:Lut mg/m^3 0 0.1E-02 45 HPLC:Chl-b mg/m^3 0.27E-01 0.43E-01 46 HPLC:DVChl-a mg/m^3 0 0 47 HPLC:Chl-a mg/m^3 0.323 0.482 48 HPLC:Phe mg/m^3 0 0 49 HPLC:B-Car mg/m^3 0.5E-02 0.6E-02 50 HPLC:TChl-a mg/m^3 0.323 0.482 51 Flag:HPLC ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 5 I I 0 3 -99 ' ' 5 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 8 F ' ' 3 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 5 I I 0 12 -99 ' ' 9 F R4 4 13 -99 ' ' 3 NQ C ' ' 14 -99 ' ' 8 F R4 3 15 -99 ' ' 3 NQ C ' ' 16 -99 ' ' 6 F R4 1 17 -99 ' ' 3 NQ C ' ' 18 -99 ' ' 6 F R4 1 19 -99 ' ' 3 NQ C ' ' 20 -99 ' ' 7 F R4 2 21 -99 ' ' 3 NQ C ' ' 22 -99 ' ' 7 F R4 2 23 -99 ' ' 3 NQ C ' ' 24 -99 ' ' 7 F R4 2 25 -99 ' ' 3 NQ C ' ' 26 -99 ' ' 8 F R4 3 27 -99 ' ' 8 F R4 3 28 -99 ' ' 8 F R4 3 29 -99 ' ' 8 F R4 3 30 -99 ' ' 8 F R4 3 31 -99 ' ' 8 F R4 3 32 -99 ' ' 8 F R4 3 33 -99 ' ' 8 F R4 3 34 -99 ' ' 8 F R4 3 35 -99 ' ' 8 F R4 3 36 -99 ' ' 8 F R4 3 37 -99 ' ' 8 F R4 3 38 -99 ' ' 8 F R4 3 39 -99 ' ' 8 F R4 3 40 -99 ' ' 8 F R4 3 41 -99 ' ' 8 F R4 3 42 -99 ' ' 8 F R4 3 43 -99 ' ' 8 F R4 3 44 -99 ' ' 8 F R4 3 45 -99 ' ' 8 F R4 3 46 -99 ' ' 8 F R4 3 47 -99 ' ' 8 F R4 3 48 -99 ' ' 8 F R4 3 49 -99 ' ' 8 F R4 3 50 -99 ' ' 8 F R4 3 51 -99 ' ' 3 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2010-13 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P25 EVENT NUMBER : 76 LATITUDE : 50 0.05000 N ! (deg min) LONGITUDE : 143 36.31000 W ! (deg min) WATER DEPTH : 4145 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 LOCATION : Mid-ship ! custom item $REMARKS SOFTWARE VERSION SEASAVE V 7.18C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2010/08/24 16:15:40 242 242 CLEAN 5.0.2 2010/08/24 16:16:12 ? ? ADDSAMP 3.4 2010/08/27 11:52:56 242 242 BINAVE 4.1.1 2010/08/27 11:53:14 242 2 CALIB 11.7 2010/09/03 11:34:51 2 2 MERGE 3.4 2010/10/20 16:06:04 2 2 CLEAN 5.0.2 2010/10/20 16:06:12 ? ? CALIB 11.7 2010/11/09 11:43:03 2 2 SORT 3.5 2010/11/09 11:43:15 2 2 REMOVECH 8.0 2010/11/09 11:45:28 2 2 CHGUNITS 3.0 2010/11/09 11:45:46 2 2 REORDER 1.2.1 2010/11/09 11:45:53 ? ? HDREDIT2 2.5.1 2010/11/10 15:51:32 ? ? HDREDIT2 2.5.1 2010/11/15 17:37:06 ? ? CALIB 11.7 2013/06/04 13:14:16 2 2 HDREDIT2 2.6 2013/07/08 08:50:24 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:31:32 2 2 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:34:49 2 2 CHANGE_FLAGS 2.0 2014/11/20 09:57:06 2 2 SORT 3.6 2020/11/25 10:30:25 2 2 REORDER 1.3.1 2021/11/24 16:34:31 ? ? MERGE 3.5.1 2021/11/24 16:34:46 2 2 SORT 3.6 2021/11/24 16:34:53 2 2 CLEAN 5.2.4 2021/11/24 16:35:03 2 2 HDREDIT2 3.2 2021/11/24 16:35:23 ? ? HDREDIT2 3.2 2021/11/24 16:35:43 ? ? $END $REMARKS -CLEAN functions: 2010/08/24 16:15:49 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data_Processing\2010-13\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -CALIB parameters: 2010/09/03 11:34:51 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2010-13\Processing\doc\2010-13-recal-press.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 2 Pressure dbars 10 0.0000000E+00 0.9998800E+00 -The following MERGE parameters were used: 2010/10/20 16:06:01 2010/10/20 16:06:01 2010/10/20 16:06: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Flag:Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, Dimethyl_Sulphide, Flag:Dimethyl_Sulphide Primary file : Q:\Cruise_Data_Processing\2010-13\Processing\hydro\2010-13-0076.samavg Secondary file: Q:\Cruise_Data_Processing\2010-13\Processing\hydro\2010-13-0076.mrgcln1 -CLEAN functions: 2010/10/20 16:06:09 20 Remove Sea-Bird comments from the header. -CALIB parameters: 2010/11/09 11:43:03 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2010-13\Processing\doc\2010-13-recal-bottle.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 8 Transmissivity %/metre 10 0.0000000E+00 0.2500000E+01 17 Salinity:T1:C1 PSS-78 10 -0.2500000E-02 0.1000000E+01 18 Oxygen:Dissolved:SBE mL/L 10 0.5700000E-02 0.1041400E+01 -SORT parameters: 2010/11/09 11:43:15 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2010/11/09 11:45:28 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] PAR [uE/m^2/sec] pH:SBE [pH Units] Status:Pump Descent_Rate [m/s] Altimeter [metres] Salinity:T0:C0 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE [mL/L]' changed from mL/L to umol/kg -HEADER EDITS: 2010/11/10 15:51:32 Applied edit header: Q:\Cruise_Data_Processing\2010-13\Processing\doc\2010-13-bot-hdr.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 13: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 14: Chlorophyll:Extracted [mg/m^3] Units: ==> mg/m^3 Format: F8.3 ==> F7.2 Channel 15: Flag:Chlorophyll:Extracted [n/a] Units: ==> n/a Channel 18: Oxygen:Dissolved [mL/L] Units: ==> mL/L Channel 19: Flag:Oxygen:Dissolved [n/a] Units: ==> n/a Channel 16: Phaeo-Pigment:Extracted [mg/m^3] Units: ==> mg/m^3 -HEADER EDITS: 2010/11/15 17:37:06 Channel 11: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 10: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number -CALIB parameters: 2013/06/04 13:14:16 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\Nutrients\doc\Nutrients-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 20 Nitrate_plus_Nitrite umol/L 10 0.1709000E+00 0.9812000E+00 24 Phosphate umol/L 10 0.4530000E-01 0.1011500E+01 -HEADER EDITS: 2013/07/08 08:50:24 Applied edit header: C:\DATA\Nutrients\doc\headedit-correction.txt -SORT parameters: 2020/11/25 10:30:25 Sorted in ascending order of channel Sample_Number [n/a] -The following MERGE parameters were used: 2021/11/24 16:34:46 Merge Channel: sample_number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: HPLC:Chl-c3 [ ], HPLC:Chlide-a [ ], HPLC:MgDVP [ ], HPLC:Chl-c2 [ ], HPLC:Chl-c1 [ ], HPLC:Me-chlide [ ], HPLC:Peri [ ], HPLC:Pheide-a [ ], HPLC:But-fuco [ ], HPLC:Fuco [ ], HPLC:Neo [ ], HPLC:Pras [ ], HPLC:Viola [ ], HPLC:Hex-fuco [ ], HPLC:Diadino [ ], HPLC:Allo [ ], HPLC:Diato [ ], HPLC:Zea [ ], HPLC:Lut [ ], HPLC:Chl-b [ ], HPLC:C2mgdg, HPLC:DVChl-a [ ], HPLC:Chl-a [ ], HPLC:Phe [ ], HPLC:B-Car [ ], HPLC:TChl-a [ ], Flag:HPLC [ ] Primary file : C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2010\2010-013_Nov2021\Processing\ IOS\2010-013-0076.che2 Secondary file: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2010\2010-013_Nov2021\Processing\ IOS\2010-013-0076.hplc -SORT parameters: 2021/11/24 16:34:53 Sorted in ascending order of channel Pressure [decibar] -CLEAN functions: 2021/11/24 16:35:02 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Change character data from " " to "0" in channels Flag:* -HEADER EDITS: 2021/11/24 16:35:23 Applied edit header: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2010\2010-013-bot-hdr1.txt Channel 2: Bottle_Number [n/a] Format: I3 ==> I5 Channel 3: Bottle:Firing_Sequence [n/a] Format: I3 ==> I5 Channel 26: HPLC:Chl-c3 [mg/m^3] Units: ==> mg/m^3 Channel 27: HPLC:Chlide-a [mg/m^3] Units: ==> mg/m^3 Channel 28: HPLC:MgDVP [mg/m^3] Units: ==> mg/m^3 Channel 29: HPLC:Chl-c2 [mg/m^3] Units: ==> mg/m^3 Channel 30: HPLC:Chl-c1 [mg/m^3] Units: ==> mg/m^3 Channel 31: HPLC:Me-chlide [mg/m^3] Units: ==> mg/m^3 Channel 32: HPLC:Peri [mg/m^3] Units: ==> mg/m^3 Channel 33: HPLC:Pheide-a [mg/m^3] Units: ==> mg/m^3 Channel 34: HPLC:But-fuco [mg/m^3] Units: ==> mg/m^3 Channel 35: HPLC:Fuco [mg/m^3] Units: ==> mg/m^3 Channel 36: HPLC:Neo [mg/m^3] Units: ==> mg/m^3 Channel 37: HPLC:Pras [mg/m^3] Units: ==> mg/m^3 Channel 38: HPLC:Viola [mg/m^3] Units: ==> mg/m^3 Channel 39: HPLC:Hex-fuco [mg/m^3] Units: ==> mg/m^3 Channel 40: HPLC:Diadino [mg/m^3] Units: ==> mg/m^3 Channel 41: HPLC:Allo [mg/m^3] Units: ==> mg/m^3 Channel 42: HPLC:Diato [mg/m^3] Units: ==> mg/m^3 Channel 43: HPLC:Zea [mg/m^3] Units: ==> mg/m^3 Channel 44: HPLC:Lut [mg/m^3] Units: ==> mg/m^3 Channel 45: HPLC:Chl-b [mg/m^3] Units: ==> mg/m^3 Channel 46: HPLC:DVChl-a [mg/m^3] Units: ==> mg/m^3 Channel 47: HPLC:Chl-a [mg/m^3] Units: ==> mg/m^3 Channel 48: HPLC:Phe [mg/m^3] Units: ==> mg/m^3 Channel 49: HPLC:B-Car [mg/m^3] Units: ==> mg/m^3 Channel 50: HPLC:TChl-a [mg/m^3] Units: ==> mg/m^3 -HEADER EDITS: 2021/11/24 16:35:43 Applied edit header: C:\Users\Samantha\OneDrive\Documents\SH ios\HPLC\2010\2010-013-bot-hdr2.txt $END *COMMENTS Comments from secondary file: Q:\Cruise_Data_Processing\2010-13\Processing\hydro\2010-13-0076.mrgcln1 ----------------------------------------------------------------------- Comments from secondary file: Q:\Cruise_Data_Processing\2010-13\Processing\HYDRO\2010-13-0076.add ------------------------------------------------------------------- Sample_Number 565: DO: endpoint overshot, value looks oddly low Analysis methods: - ----------------- Chlorophyll and Phaeo-Pigments samples were analyzed at sea using a Chemistry Turner Designs 10AU fluorometer which was calibrated on May 12, 2009 using pure chlorophyll a. Chlorophyll and Phaeo-Pigments precision was determined by analyzing replicate samples drawn from one Niskin. For details see worksheet “Precision” in file QF 2010-13 CHLChauv.xls. HPLC samples were filtered onto 47mm GF/F filters and stored at -80C prior to analysis. Samples were extracted in 95% methanol at -20C for 24 hours in the lab and analyzed on a WATERS 2695 HPLC separations system as detailed in Nemcek and Pena, 2014. Analysis was performed ~6-7 months after collection. The average of two samples is reported. Variability is assessed as the %CV (std dev/mean*100) for duplicate pairs. All pigments below the limit of detection (LOD) are assigned a zero value. TChl-a is the sum of Chl-a, DVchl-a, Chlide-a and Me-chlide For further information see file QF 2010-013_HPLC*.xlsx. Oxygen samples were analyzed at sea using an automated Winkler titration system with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). The titration system consists of a Brinkmann 665 Dosimat, a UV light source and a UV detector with a 365nm filter custom built by Scripps Institution of Oceanography. For details including a duplicate analysis, see document 2010-13oxy.xls. Salinity samples were collected in glass bottles and analyzed at sea using a Guildline Portasal (#58879) or at IOS on a Guildline model 8400B Autosal standardized with IAPSO standard seawater. See file 2010-13sal.xls for Autosal data and 2010-13 P8 Sal.txt and 2010-13-P16.txt for Portasal data. For information on precision see 2010-13-sal-duplicates.xls. Nutrient samples were collected in plastic tubes. Most samples were analyzed frozen at IOS using an Astoria autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). Deep silicate samples (400m and below) were analyzed cool at IOS. For full data and details on nutrient duplicates and precision see file QF2010-13nuts.xls. NOTE: FROZEN SAMPLES WERE ACCIDENTALLY THAWED FOR 2 DAYS AT ROOM TEMPERATURE THEN STORED COOL UNTIL ANALYZED. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2010-13 DMS Report.doc and for data see DMS 2010-13 summary.xls. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. Culberson C.H. (1991) Dissolved oxygen. In WOCE Operations Manual. Volume 3: The Observational Program. Section 3.1: WOCE Hydrographic Program. Part 3.1.3: WHP Operations and Methods. WHP Office Report WHPO 91-1 / WOCE Report No. 68/91. 3. Barwell-Clarke, J. and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 4. Nemcek, N. and Peña, M.A. 2014. Institute of Ocean Sciences Protocols for Phytoplankton Pigment Analysis by HPLC. Can. Tech. Rep. Fish. Aquat. Sci. 3117: x + 80 p. ----------------------------------------------------------------------------------- ********************************************************************************** Transmissometer #1005DR was calibrated in March 2008, and drifted significantly but steadily until July 2009; then a sudden shift occurred, so that maximum values between September 2009 and July 2010 were very low, ~25%/m. In August 2010 a study was made of transmissivity that led to a decision to apply post-processing corrections to all cruises between March 2008 and June 2010. Transmissivity data from this cruise were corrected by multiplying the original values by correction factor 2.5, which was based on the assumption that deep offshore transmissivity should be about 62%/m. For details on the transmissometer post-processing see: OSD_Data_Archive:\Cruise_Data\DOCUMENTS\Transmissometer 1005DR Corrections.doc These data should still be considered nominal. ********************************************************************************** July 2013: A correction has been applied to Nitrate_plus_Nitrite and Phosphate data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the following report: Corrections to Nitrate and Phosphate for Deep-Water Cruises from 2009 to 2012.pdf which is stored in folder: \\Cruise_Data\DOCUMENTS\Analysis Reference Papers *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- --------- ---- ------ ------------ Pressure dbars 10 -99 () (0 0.99988) Transmissivity %/metre 10 -99 () (0 2.5) Salinity:T1:C1 PSS-78 10 -99 () (-0.25E-02 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.57E-02 1.0414) Nitrate_plus_Nitrite umol/L 10 -99 () (0.1709 0.9812) Phosphate umol/L 10 -99 () (0.453E-01 1.0115) $END !-1-- -2-- -3-- --4--- ---5---- --6-- ---7--- ---8---- --9--- --10- -11- ---12--- 13 ---14-- 15 --16- 17 --18- 19 --20-- 21 --22-- 23 --24-- 25 ---26-- ---27-- ---28-- ---29-- ---30-- ---31-- ---32-- ---33-- ---34-- ---35-- ---36-- ---37-- ---38-- ---39-- ---40-- ---41-- ---42-- ---43-- ---44-- ---45-- ---46-- ---47-- ---48-- ---49-- ---50-- 51 !Samp Bott Bott Pressu Temperat Trans Fluores Salinity Oxygen Oxyge Numb Salinity Fl Oxygen: Fl Nitra Fl Silic Fl Phosph Fl Chloro Fl Phaeo- Fl HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC: HPLC:B- HPLC: Fl !le_ le_ le:F re ure: missi cence: :T1:C1 : n: er_o :Bottle ag Dissolv ag te_ ag ate ag ate ag phyll: ag Pigmen ag Chl-c3 Chlide- MgDVP Chl-c2 Chl-c1 Me- Peri Pheide- But- Fuco Neo Pras Viola Hex- Diadino Allo Diato Zea Lut Chl-b DVChl-a Chl-a Phe Car TChl-a ag !Numb Numb ~ng_ Secondar vity URU: Dissol Disso ~bin ~o ed ~o plus_ ~t ~i ~p Extrac ~a t: ~a a chlide a fuco fuco : !er er Sequ y Seapoin ved: lved: _rec tt lv Nitri ri ca ha ted ct Extrac ct HP ! ence t SBE SBE ords le ed te te te te ed ted ed LC !---- ---- ---- ------ -------- ----- ------- -------- ------ ----- ---- -------- -- ------- -- ----- -- ----- -- ------ -- ------ -- ------ -- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- -- *END OF HEADER 565 3 2 5.2 7.7892 52.2 0.657 32.5885 6.75 294.0 121 32.5898 0 -99.000 5 12.2 0 18.0 0 1.17 0 0.36 0 0.06 0 0.031 0.000 0.004 0.037 0.000 0.000 0.000 0.000 0.032 0.051 0.002 0.005 0.008 0.104 0.044 0.000 0.004 0.025 0.001 0.027 0.000 0.323 0.000 0.005 0.323 6 564 2 1 38.3 7.4080 51.0 1.049 32.5806 6.68 290.9 121 -99.0000 0 -99.000 0 -99.0 0 -99.0 0 -99.00 0 0.52 0 0.12 0 0.091 0.000 0.006 0.078 0.000 0.000 0.000 0.000 0.067 0.101 0.007 0.006 0.007 0.211 0.024 0.002 0.004 0.018 0.000 0.043 0.000 0.482 0.000 0.006 0.482 6