*2014/11/20 09:56:57.87 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2010/02/08 23:55:27.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 21 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 89B25CB0 NUMBER OF CHANNELS : 12 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------------ --------------- -------------- -------------- 1 Pressure decibar 3.7 3998 2 Temperature:Secondary 'deg C (ITS90)' 1.5359 6.9658 3 Transmissivity %/metre 50.85 55.14 4 Salinity:T1:C1 PSS-78 32.4564 34.6734 5 Bottle_Number n/a 1 21 6 Bottle:Firing_Sequence n/a 1 21 7 Sample_Number n/a 353 373 8 Number_of_bin_records n/a 115 121 9 Salinity:Bottle PSS-78 32.4645 34.5867 10 Flag:Salinity:Bottle n/a 11 Oxygen:Dissolved mL/L 4.133 6.821 12 Flag:Oxygen:Dissolved n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 7 F ' ' 2 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 3 I I 0 6 -99 ' ' 3 I I 0 7 -99 ' ' 5 I I 0 8 ' ' ' ' 5 I I 0 9 -99 ' ' 9 F R4 4 10 0 ' ' 3 NQ C ' ' 11 -99 ' ' 8 F R4 3 12 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2010-01 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North-East Pacific STATION : P20 EVENT NUMBER : 39 LATITUDE : 49 33.86000 N ! (deg min) LONGITUDE : 138 39.98000 W ! (deg min) WATER DEPTH : 3940 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 LOCATION : Mid-ship ! custom item $REMARKS SOFTWARE VERSION SEASAVE V 7.18 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2010/06/14 15:02:30 2413 2413 CLEAN 5.0.2 2010/06/14 15:02:48 ? ? ADDSAMP 3.4 2010/06/14 15:35:37 2413 2413 BINAVE 4.1.1 2010/06/14 15:35:51 2413 20 MERGE 3.3 2010/06/14 15:36:36 20 20 CLEAN 5.0.2 2010/10/01 15:01:32 ? ? CALIB 11.7 2010/10/01 15:01:40 20 20 SORT 3.5 2010/10/01 15:02:18 20 20 REMOVECH 8.0 2010/11/15 16:07:02 20 20 CHGUNITS 3.0 2010/11/15 16:08:21 20 20 CLEAN 5.0.2 2010/11/16 14:05:53 22 21 REORDER 1.3 2010/11/16 14:06:29 ? ? HDREDIT2 2.5.1 2010/11/16 15:56:20 ? ? CALIB 11.7 2010/11/16 15:56:24 21 21 CALIB 11.7 2013/06/04 13:13:59 21 21 HDREDIT2 2.6 2013/07/08 08:49:56 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:31:25 21 21 CHANGE_FLAGS 2.0 2014/11/20 09:56:57 21 21 $END $REMARKS -CLEAN functions: 2010/06/14 15:02:46 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data_Processing\2010-01\processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2010/06/14 15:36:35 2010/06/14 15:36:36 2010/06/14 15:36: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Phaeo-Pigment:Extracted, Flag:Phaeo-Pigment:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium, pH, Flag:pH Primary file : Q:\Cruise_Data_Processing\2010-01\Processing\hydro\2010-01-0040.samavg Secondary file: Q:\Cruise_Data_Processing\2010-01\Processing\hydro\2010-01-0040.mrgcln1 Comments from secondary file: Q:\Cruise_Data_Processing\2010-01\Processing\hydro\2010-01-0040.mrgcln1 ----------------------------------------------------------------------- -CLEAN functions: 2010/06/10 17:07:33 20 Reduce header to sections: FIL ADM LOC DEP REC INS HIS RAW CAL COM Remarks removed from kept sections. -CLEAN functions: 2010/10/01 15:01:32 Remove Sea-Bird comments from the header. -CALIB parameters: 2010/10/01 15:01:40 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2010-01\Processing\doc\2010-01-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Oxygen:Dissolved:SBE mL/L 10 0.1750000E-01 0.1098100E+01 -SORT parameters: 2010/10/01 15:02:18 Sorted in ascending order of channel Pressure [dbars] -REMOVECH 2010/11/15 16:07:02 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Fluorescence:Seapoint [mg/m^3] Oxygen:Voltage:SBE [volts] Oxygen:Dissolved:SBE [mL/L] PAR [uE/m^2/sec] pH:SBE [pH Units] Salinity:T0:C0 [PSS-78] Altimeter [metres] Descent_Rate [m/s] Status:Pump Flag -CHANGE units: - No units changed -CLEAN functions: 2010/11/16 14:05:53 Reset #RECS, MIN & MAX values in header. -HEADER EDITS: 2010/11/16 15:56:20 Applied edit header: Q:\Cruise_Data_Processing\2010-01\Processing\doc\2010-01-bot-hdr.txt Channel 1: Pressure [decibar] Units: dbars ==> decibar Format: F11.2 ==> F7.1 Channel 3: Transmissivity [%/metre] Format: F7.2 ==> F6.1 Channel 6: Bottle:Firing_Sequence [n/a] Name: Bottle_Number ==> Bottle:Firing_Sequence Channel 5: Bottle_Number [n/a] Name: Bottle:Position ==> Bottle_Number Channel 10: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 11: Oxygen:Dissolved [mL/L] Units: ==> mL/L Channel 12: Flag:Oxygen:Dissolved [n/a] Units: ==> n/a -CALIB parameters: 2010/11/16 15:56:24 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2010-01\Processing\doc\2010-01-recal-tr.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 3 Transmissivity %/metre 10 0.0000000E+00 0.2260000E+01 -CALIB parameters: 2013/06/04 13:13:59 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\Nutrients\doc\Nutrients-recal1.ccf WARNING: No calibration done on file C:\Data\Nutrients\2010-01\2010-01-0039.cor1 -HEADER EDITS: 2013/07/08 08:49:56 Applied edit header: C:\DATA\Nutrients\doc\headedit-correction.txt $END *COMMENTS Comments from secondary file: Q:\Cruise_Data_Processing\2010-01\Processing\hydro\2010-01-0040.mrgcln1 ----------------------------------------------------------------------- Comments from secondary file: Q:\Cruise_Data_Processing\2010-01\Processing\hydro\2010-01-0040.sal ------------------------------------------------------------------- Sample_Numbers 356 and 360: Salinity: OUtliers in COMPARE. Sample_Numbers 364: Salinity: OUtlier in COMPARE but CTD salinity very noisy, so bottle probably ok. Analysis methods: ----------------- Chlorophyll and Phaeo-Pigments samples were analyzed at sea using a Chemistry Turner Designs 10AU fluorometer which was calibrated on May 12, 2009 using pure chlorophyll a. Chlorophyll and Phaeo-Pigments precision was determined by analyzing replicate samples drawn from one Niskin. For details see worksheet “Precision” in file QF 2010-01 CHL.xls. Oxygen samples were analyzed at sea using an automated Winkler titration system with modifications based on Carpenter (1965) and adhering to WOCE protocols (Culberson 1991). The titration system consists of a Brinkmann 665 Dosimat, a UV light source and a UV detector with a 365nm filter custom built by Scripps Institution of Oceanography. For details see documents 2010-01oxy.xls and 2010-oxygen-duplicates.xls. Salinity samples were collected in glass bottles and analyzed at IOS on a Guildline model 8400B Autosal standardized with IAPSO standard seawater. See file 2010-01-salinity-duplicates.xls for information on precision and 2010-01-sal.xls for analysis output. Nutrient samples were collected in plastic tubes and analyzed fresh at sea using an Astoria autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). For full data and details on nutrient duplicates and precision see file QF2010-01nuts.xls. The minimum detectable level for DMS is 0.10 nM, so “0” values should be interpreted as <0.10. For details on the collection and analysis of the DMS data see file 2010-01 DMS Report.doc and for data see DMS 2010-01 summary.xls. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. Culberson C.H. (1991) Dissolved oxygen. In WOCE Operations Manual. Volume 3: The Observational Program. Section 3.1: WOCE Hydrographic Program. Part 3.1.3: WHP Operations and Methods. WHP Office Report WHPO 91-1 / WOCE Report No. 68/91. 3. Barwell-Clarke, J. and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. ****************************************************************************** Fluorescence data were removed because of severe problems with spikes and higher than usual values at depth suggesting problems with the cable. The data may be obtained from the chief scientist. ****************************************************************************** Transmissometer #1005DR was calibrated in March 2008, and drifted significantly but steadily until July 2009; then a sudden shift occurred, so that maximum values between September 2009 and July 2010 were very low, ~25%/m. In August 2010 a study was made of transmissivity that led to a decision to apply post-processing corrections to all cruises between March 2008 and June 2010. Transmissivity data from this cruise were corrected by multiplying the original values by correction factor 2.26, which was based on the assumption that deep offshore transmissivity should be about 62%/m. For details on the transmissometer post-processing see: OSD_Data_Archive:\Cruise_Data\DOCUMENTS\Transmissometer 1005DR Corrections.doc These data should still be considered nominal. ****************************************************************************** THe SBE Dissolved Oxygen data were removed from this cast due to poor comparison with bottles and with other casts at the same site. ****************************************************************************** July 2013: A correction has been applied to Nitrate_plus_Nitrite and Phosphate data from deep-water cruises analyzed at IOS between 2009 and 2012. For details see the following report: Corrections to Nitrate and Phosphate for Deep-Water Cruises from 2009 to 2012.pdf which is stored in folder: \\Cruise_Data\DOCUMENTS\Analysis Reference Papers *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- --------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.175E-01 1.0981) Transmissivity %/metre 10 -99 () (0 2.26) $END !--1--- ---2---- --3--- ---4---- 5- 6- -7-- -8-- ---9---- 10 ---11-- 12 !Pressu Temperat Transm Salinity Bo Bo Samp Numb Salinity Fl Oxygen: Fl !re ure: issivi :T1:C1 tt tt le_ er_o :Bottle ag Dissolv ag ! Secondar ty ~u ~u Numb ~bin ~o ed ~o ! y mb en er _rec tt lv ! er ce ords le ed !------ -------- ------ -------- -- -- ---- ---- -------- -- ------- -- *END OF HEADER 3.7 6.9658 51.08 32.4565 21 21 373 121 32.4645 0 -99.000 0 9.2 6.9640 51.08 32.4566 20 18 370 121 -99.0000 0 -99.000 0 9.3 6.9634 51.08 32.4565 17 19 371 121 -99.0000 0 -99.000 0 9.4 6.9643 51.08 32.4565 6 17 369 115 -99.0000 0 -99.000 0 9.5 6.9640 50.85 32.4564 14 20 372 121 -99.0000 0 6.821 6 50.9 6.9451 51.75 32.4731 19 15 367 120 -99.0000 0 -99.000 0 51.1 6.9447 51.75 32.4727 13 16 368 121 32.4796 0 -99.000 0 98.7 5.7963 54.92 32.7404 16 13 365 121 -99.0000 0 6.556 0 98.7 5.7934 54.92 32.7422 18 14 366 121 -99.0000 0 -99.000 0 149.8 5.8856 55.14 33.6633 12 12 364 121 33.6610 0 -99.000 0 199.9 5.3445 54.92 33.7700 15 11 363 121 -99.0000 0 4.133 6 249.8 4.6938 55.14 33.8112 5 10 362 121 -99.0000 0 -99.000 0 399.5 4.0945 55.14 33.9921 4 9 361 121 -99.0000 0 -99.000 0 499.7 3.9828 55.14 34.1038 11 8 360 121 34.1240 3 -99.000 0 601.6 3.7155 54.92 34.1744 3 7 359 121 -99.0000 0 -99.000 0 1000.9 2.9868 54.47 34.3638 2 6 358 121 -99.0000 0 -99.000 0 1000.9 2.9867 54.47 34.3638 10 5 357 121 34.3730 0 -99.000 0 1400.0 2.4873 53.79 34.4711 9 4 356 121 34.4850 3 -99.000 0 1701.8 2.1871 53.56 34.5336 8 3 355 121 34.5434 0 -99.000 0 2002.6 1.9526 53.34 34.5807 7 2 354 121 34.5867 0 -99.000 0 3998.0 1.5359 51.53 34.6734 1 1 353 121 -99.0000 0 -99.000 0