*2013/07/29 14:31:19.89 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2009/04/18 17:51:34.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 6 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 2267E30F NUMBER OF CHANNELS : 12 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 154 159 2 Pressure decibar 1.7 19.9 3 Temperature:Secondary 'deg C (ITS90)' 7.7121 8.4437 4 Transmissivity %/metre 25.461 55.596 5 Fluorescence:URU:Seapoint mg/m^3 0.272 5.201 6 PAR uE/m^2/sec 5.8 1366.6 7 PAR:Reference uE/m^2/sec 2349.3 2511 8 Salinity:T1:C1 PSS-78 29.4509 29.7792 9 Oxygen:Dissolved:SBE mL/L 5.34 8.51 10 Oxygen:Dissolved:SBE umol/kg 232.9 371.4 11 Bottle_Number n/a 1 6 12 Number_of_bin_records n/a 236 241 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 1 7 -99 ' ' 7 F ' ' 1 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 7 F ' ' 2 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 3 I I 0 12 ' ' ' ' 5 I I 0 $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2009-34 AGENCY : 'WVL, Marine Environment and Habitat Science,' CONTINUED : ' Vancouver, B.C.' COUNTRY : Canada PROJECT : Coastal Ecosystem Research Project SCIENTIST : Sutherland T. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Strait of Georgia STATION : BS10 EVENT NUMBER : 19 LATITUDE : 49 32.01000 N ! (deg min) LONGITUDE : 124 51.02000 W ! (deg min) WATER DEPTH : 23 ALTIMETER (M) : 1.98 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 4883 conductivity:primary ' ' 1763 pressure ' ' 75636 temperature:secondary ' ' 2095 conductivity:secondary ' ' 2754 Fluorometer ' ' Seapoint transmissometer:primary ' ' 1005dr Oxygen:SBE ' ' 1119 altimeter: ' ' ' ' irradiance:primary ' ' 4565 surface ' ' 'degrees = 0.0' $END $REMARKS SOFTWARE VERSION SEASAVE V 7.16 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2009/09/12 17:33:13 1441 1441 ADTIMCH 4.3 2009/09/13 13:41:34 1441 1441 ADDSAMP 3.4 2009/09/13 13:49:35 1441 1441 BINAVE 4.1.1 2009/09/13 13:51:17 1441 6 MERGE 3.3 2009/09/13 15:22:00 6 6 CLEAN 5.0.2 2009/09/13 15:22:04 ? ? CALIB 11.7 2009/09/13 16:49:16 6 6 SORT 3.5 2009/09/13 17:03:01 6 6 REMOVECH 8.0 2009/09/13 17:03:43 6 6 CHGUNITS 3.0 2009/09/13 17:03:55 6 6 REORDER 1.2.1 2009/09/13 17:04:18 ? ? HDREDIT2 2.5.1 2009/09/13 17:09:55 ? ? CALIB 11.7 2010/08/18 16:12:51 6 6 HDREDIT2 2.5.1 2010/08/18 16:13:37 ? ? HDREDIT2 2.5.1 2010/09/02 14:16:07 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:31:19 6 6 $END $REMARKS -The following ADTIMCH parameters were used. Add 96.00 hours to times in header file section -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data_Processing\2009-34\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2009/09/13 15:21:59 2009/09/13 15:21:59 2009/09/13 15:21: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle [ ], Flag:Salinity:Bottle [ ], Chlorophyll:Extracted [ ], Flag:Chlorophyll:Extracted [ ], Oxygen:Dissolved [ ], Flag:Oxygen:Dissolved [ ], Nitrate_plus_Nitrite [umol/L], Flag:Nitrate_plus_Nitrite [ ], Silicate [umol/L], Flag:Silicate [ ], Phosphate [umol/L], Flag:Phosphate [ ], Dimethyl_Sulphide [nmol/L], Flag:Dimethyl_Sulphide [ ] Primary file : Q:\Cruise_Data_Processing\2009-34\Processing\hydro\2009-34-0019.samavg Secondary file: Q:\Cruise_Data_Processing\2009-34\Processing\hydro\2009-34-0019.mrgcln1 -CLEAN functions: 2009/09/13 15:22:03 20 Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2009/09/13 16:49:16 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2009-34\Processing\doc\2009-34-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 18 Oxygen:Dissolved:SBE mL/L 10 0.8800000E-02 0.1038800E+01 -SORT parameters: 2009/09/13 17:03:01 Sorted in ascending order of channel Pressure -REMOVECH 2009/09/13 17:03:43 10 channels removed. -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -HEADER EDITS: 2009/09/13 17:09:55 Applied edit header: Q:\Cruise_Data_Processing\2009-34\Processing\doc\2009-34-bot-hdr.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 7: PAR:Reference [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 9: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 -CALIB parameters: 2010/08/18 16:12:51 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\Trans Cor\2009-34\DOC\2009-34-recal-tr.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 4 Transmissivity %/metre 10 0.0000000E+00 0.1230000E+01 -HEADER EDITS: 2010/08/18 16:13:37 Applied edit header: Q:\Cruise_Data_Processing\Trans Cor\2009-34\DOC\Trans_Correction1.TXT -HEADER EDITS: 2010/09/02 14:16:07 Channel 4: Transmissivity [%/metre] Format: F7.2 ==> F6.1 $END *COMMENTS Analysis methods: ----------------- Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). Samples were analyzed at sea using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. References: Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. ********************************************************************************* Transmissometer #1005DR was calibrated in March 2008, and drifted significantly but steadily until July 2009; then a sudden shift occurred, so that maximum values between September 2009 and July 2010 were very low, ~25%/m. In August 2010 a study was made of transmissivity that led to a decision to apply post-processing corrections to all cruises between March 2008 and June 2010. Transmissivity data from this cruise were corrected by multiplying the original values by a correction factor, which was based on assumptions that deep offshore transmissivity from a June 2009 cruise should be about 62%/m and that drift was linear with time between March 2008 and July 2009. The corrections produced reasonable results for all cruises in that time period. For details on how the correction factor was derived see: OSD_Data_Archive:\Cruise_Data\DOCUMENTS\Transmissometer 1005DR Corrections.doc These data should be considered estimates. ********************************************************************************* *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- --------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.88E-02 1.0388) Transmissivity %/metre 10 -99 () (0 1.23) $END !-1-- --2--- ---3---- --4-- ---5--- --6--- --7--- ---8---- --9--- --10- 11 -12- !Samp Pressu Temperat Trans Fluores PAR PAR: Salinity Oxygen Oxyge Bo Numb !le_ re ure: missi cence: Refere :T1:C1 : n: tt er_o !Numb Secondar vity URU: nce Dissol Disso ~u ~bin !er y Seapoin ved: lved: mb _rec ! t SBE SBE er ords !---- ------ -------- ----- ------- ------ ------ -------- ------ ----- -- ---- *END OF HEADER 159 1.7 8.4437 25.6 3.769 1366.6 2376.1 29.4509 8.51 371.4 6 236 158 5.1 8.2453 25.5 5.201 97.5 2456.3 29.5370 8.14 355.1 5 241 157 9.9 7.8639 55.6 0.957 22.0 2479.2 29.7291 6.26 273.0 4 241 156 14.9 7.7608 52.4 0.384 9.7 2511.0 29.7510 5.65 246.4 3 241 155 17.3 7.7215 49.0 0.293 8.0 2492.2 29.7627 5.36 233.8 2 241 154 19.9 7.7121 47.2 0.272 5.8 2349.3 29.7792 5.34 232.9 1 241