*2025/01/07 14:21:53.73 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2007/07/31 08:37:00.000 NUMBER OF RECORDS : 24 DATA DESCRIPTION : 'Bottle:Rosette:Up:NoStop and Stop as specified in' CONTINUED : ' SAMPLE METHOD' FILE TYPE : ASCII NUMBER OF CHANNELS : 40 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- -------------------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 198 221 2 Sample_Method n/a 3 Bottle_Number n/a 1 24 4 Pressure decibar 7.2 2787.2 5 Temperature 'deg C (ITS90)' -1.5097 0.6257 6 Salinity PSS-78 26.2683 34.9577 7 Oxygen:Dissolved:SBE mL/L 6.25 9.2 8 Fluorescence:Calibrated:Seapoint mg/m^3 0.33E-01 0.301 9 Transmissivity %/metre 89.78 90.5 10 Nitrate_plus_Nitrite:ISUS volts 0 0 11 PAR uE/m^2/sec 0 0 12 PAR:Reference uE/m^2/sec 101.91 228.82 13 Salinity:Bottle PSS-78 26.639 34.9584 14 Flag:Salinity:Bottle n/a 15 Oxygen:Dissolved mL/L 6.201 9.197 16 Oxygen:Dissolved umol/kg 276.93 410.72 17 Flag:Oxygen:Dissolved n/a 18 Nitrate_plus_Nitrite umol/L 0 15.9 19 Flag:Nitrate_plus_Nitrite n/a 20 Silicate umol/L 2.4 35.5 21 Flag:Silicate n/a 22 Ammonium umol/L 0 0.1E-01 23 Flag:Ammonium n/a 24 Alkalinity:Total:Potentiometric umol/kg 1928.8 2188.7 25 Flag:Alkalinity:Total:Potentiometric n/a 26 Chlorophyll:Extracted mg/m^3 0.17E-01 0.222 27 Flag:Chlorophyll:Extracted n/a 28 Phaeo-Pigment:Extracted mg/m^3 0.1E-01 0.45 29 Flag:Phaeo-Pigment:Extracted n/a 30 Chlorophyll:Extracted:0.3um mg/m^3 0.12E-01 0.187 31 Flag:Chlorophyll:Extracted:0.3um n/a 32 Phaeo-Pigment:Extracted:0.3um mg/m^3 0 0.34 33 Flag:Phaeo-Pigment:Extracted:0.3um n/a 34 Oxygen:Isotope:18 /mille -3.6 0.31 35 Flag:Oxygen:Isotope:18 n/a 36 Barium:Dissolved nmol/L 43 70 37 Flag:Barium:Dissolved n/a 38 Bacteria /mL 44026 176560 39 Picophytoplankton /mL 16 4699 40 Nanophytoplankton /mL 42 383 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 ' ' ' ' 8 NQ C ' ' 3 -99 ' ' ' ' I5 I ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' 5 -99 ' ' ' ' F9.4 R4 ' ' 6 -99 ' ' ' ' F9.4 R4 ' ' 7 -99 ' ' ' ' F7.2 R4 ' ' 8 -99 ' ' ' ' F8.3 R4 ' ' 9 -99 ' ' ' ' F7.2 R4 ' ' 10 -99 ' ' ' ' F7.3 R4 ' ' 11 -99 ' ' ' ' F11.3 R4 ' ' 12 -99 ' ' ' ' F11.3 R4 ' ' 13 -99 ' ' ' ' F9.4 R4 ' ' 14 ' ' ' ' 3 NQ C ' ' 15 -99 ' ' ' ' F8.3 R4 ' ' 16 -99 ' ' ' ' F7.2 R4 ' ' 17 ' ' ' ' 3 NQ C ' ' 18 -99 ' ' ' ' F6.1 R4 ' ' 19 ' ' ' ' 3 NQ C ' ' 20 -99 ' ' ' ' F6.1 R4 ' ' 21 ' ' ' ' 3 NQ C ' ' 22 -99 ' ' ' ' F7.2 R4 ' ' 23 ' ' ' ' 3 NQ C ' ' 24 -99 ' ' ' ' F8.2 R4 ' ' 25 ' ' ' ' 3 NQ C ' ' 26 -99 ' ' ' ' F8.3 R4 ' ' 27 ' ' ' ' 3 NQ C ' ' 28 -99 ' ' ' ' F7.2 R4 ' ' 29 ' ' ' ' 3 NQ C ' ' 30 -99 ' ' ' ' F8.3 R4 ' ' 31 ' ' ' ' 3 NQ C ' ' 32 -99 ' ' ' ' F7.2 R4 ' ' 33 ' ' ' ' 3 NQ C ' ' 34 -99 ' ' ' ' F7.2 R4 ' ' 35 ' ' ' ' 3 NQ C ' ' 36 -99 ' ' ' ' F7.1 R4 ' ' 37 ' ' ' ' 3 NQ C ' ' 38 -99 ' ' ' ' F11.2 R4 ' ' 39 -99 ' ' ' ' F10.2 R4 ' ' 40 -99 ' ' ' ' F10.2 R4 ' ' $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ------------------------------------------------------------------------------------------ 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ------------------------------------------------------------------------------------------ Sampling Methods are expressed with the following codes: -------------------------------------------------------------------------------------- ROS:UN - No Stop ROS:US - Stop for 30 seconds ROS:USM - Up Stop Mix (Stop 30s, up 1m, down 2m, up 1m, wait 30s, close bottle) -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2007-20 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C COUNTRY : Canada PROJECT : Joint Ocean Ice Study (JOIS incl JWACS and BGOS) SCIENTIST : McLaughlin F. PLATFORM : Louis S. St. Laurent *LOCATION STATION : CB23a EVENT NUMBER : 12 LATITUDE : 72 53.81000 N ! (deg min) LONGITUDE : 136 0.52000 W ! (deg min) WATER DEPTH : 2748 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SPRD2IS 5.1 2017/03/25 11:14:27 24 24 CLEAN 5.2.2 2017/03/25 11:15:49 24 24 SORT 3.6 2017/03/25 11:21:42 24 24 HDREDIT2 3.1.1 2017/04/01 12:39:39 ? ? CHANGE_FLAGS 2.0 2017/04/01 12:59:00 24 24 HDREDIT2 3.2 2025/01/07 14:21:53 ? ? $END $REMARKS -CLEAN functions: 2017/03/25 11:15:48 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 16 deleted. -SORT parameters: 2017/03/25 11:21:42 Sorted in ascending order of channel Pressure [decibar] -HEADER EDITS: 2017/04/01 12:39:39 Applied edit header: Z:\SHARE\DATA\Data Archive Process - 2017\Joe's work\2007-20\Headers\2007-20 CHE Header.txt -HEADER EDITS: 2025/01/07 14:21:53 - none. $END *INSTRUMENT $REMARKS A rosette, holding 24 ten-litre Niskin Bottles, with a CTD was used. $END *CALIBRATION $TABLE: CORRECTED CHANNELS !Name Units Fmla Pad Coefficients !--------------------------- ------------ ---- ------ ------------ Conductivity:Primary mS/cm 10 -99 () (0.18E-02 1) Conductivity:Secondary mS/cm 10 -99 () (0.16E-02 1) Fluorescence:URU:Seapoint mg/m^3 10 -99 () (-0.45E-02 0.7909) Transmissivity %/metre 10 -99 () (0.559E-01 0.525E-01) Transmissivity %/metre 10 -99 () (-1.084 19.36) PAR uE/m^2/sec 10 -99 () (0 1.5976) $END *COMMENTS CTD Data Processing Notes: -------------------------- For full details see report Physical and chemical data from the Canada Basin July 26 to August 31, 2007 cited below. Standard seabird processing steps and Matlab based routines were used. CTD Pressure: Lab calibration (29th Oct 2002) adjusted by applying -0.48dbar offset to the bias based on in-air surface readings of the CTD. CTD Temperature: Pre-cruise lab calibration was used after comparisons with dual sensor and post-cruise calibration information. CTD Conductivity: Pre-cruise lab calibration adjusted after comparisons with dual sensor, post-cruise calibrations and water sample data. Primary conductivity adjusted by bias of +0.0018 mS/cm . Secondary conductivity adjusted by bias of +0.0016 mS/cm. CTD Oxygen: Oxygen data are from a SeaBird SBE43 sensor with pumped flow in-line after the primary temperature and conductivity sensors. A lag of -8 seconds was applied to oxygen voltage in the Seabird processing step Align. Downcast CTD oxygen voltage and upcast temperature and salinity were used to calibrate CTD to water sample oxygen (upcast). The 107 casts required 6 calibration groups. Fitting method followed Seabirds Application Note 64-2 (“SBE 43 Dissolved Oxygen Sensor Calibration and Data Corrections using Winkler Titrations”). A remaining pressure dependent shape in the residual between water sample and CTD oxygen was removed by subtracting a mean curve. Parts of the mean curve were found by fitting sections of data from discreet pressure ranges. The parts were then stitched together via spline interpolation to create a full profile mean curve. CTD Fluorometer: Fluorometer data are from a Seapoint sensor with pumped flow in-line after the secondary temperature and conductivity sensors. Calibration with bottle data performed using bottle chlorophyll values between 0.025 and 0.60 mg/m3. The number of observations used were 116 out of 141 with a standard deviation of 0.03 in the residuals. Coefficients used: Slope: 0.7909, Bias: -0.0045. Alignment of -4 seconds was used. Frequent single dropouts in fluorescence to 0 have been fixed by setting to neighbor value. ISUS: Data are uncalibrated. The voltage is proportional to nitrate. Transmissometer data are unprocessed, using calibration from 28 Aug 2006. PAR data are unprocessed, using corrected calibration from 13 Mar 2007. Altimeter data are unprocessed, using calibration from Mar 2005. Data Notes: - Spikes in temperature, conductivity and oxygen have been linearly interpolated over and where needed secondary values (when available) have replaced the primary values. Chemistry Sampling and Analysis Methods: --------------------------------------- For full details see report "Physical and chemical Data from the Canada Basin, July 26 to August 31, 2007." cited below. Salinity samples were collected in 200 mL type II glass bottles with disposable plastic inserts and screw caps. On board, samples were analyzed in a temperature-controlled lab on a Guildline AutoSalinometer Model 8400B (SN: 69086), which was standardized with IAPSO standard seawater. Onshore, 2 casts were analyzed November 2007 on the Guildline AutoSalinometer Model 8400B (SN: 68572), which was standardized with IAPSO standard seawater. Dissolved Oxygen: Oxygen samples were collected in glass flasks and analyzed on board on an automated Micro-Winkler titration system following the procedures of Carpenter (1965). The titration was performed with a Metrohn Dosimat 665 and the end point was detected using a Brinkmann probe Colorimeter PC910 (SN: 910-358). Software written at the Institute of Ocean Sciences, NewAutoOxy.exe, was used to calculate dissolved oxygen (ml/L). Oxygen data received correction post-cruise in May 2008 and February 2009 of 0.0 to 0.3 mL/L after recalibrating the volume of potassium iodide standard, identifing one unexplained drift in the uniform bottom water, and recalibrating flask volumes. Nutrient samples (nitrate plus nitrite, silicate and orthophosphate) were collected in polystyrene test tubes. If analysis could be performed on board within 24 hours the samples were stored at 4 degree C, if not they were frozen at -20 degree C. Note Surfactants for all three nutrients were misplaced during shipping. Palmolive dish detergent was an effective surfactant for nitrate and silicate but not for phosphate. Beginning August 12th with Cast 43, all phosphate samples were frozen in glass for analysis at the Institute of Ocean Sciences(IOS). Frozen samples were analyzed at IOS February and March 2008. Samples were not filtered. Samples were analyzed using a Technicon auto-analyzer following methods described in Barwell-Clarke and Whitney (1996). Ammonium samples were collected in 50 mL glass tubes, and analysed onboard following the Holmes et al. (1999) fluorometric protocol. Samples were kept in the dark for 5 to 8 hours at room temperature. Samples were then measured using a Turner Designs TD-700 fluorometer. Oxygen Isotopes Samples were collected into 30 ml glass vials. Once at room temperature, the caps were retightened and wrapped with parafilm for storage. The bulk of the samples (623) were analyzed January to March 2008 at Oregon State University's COAS Stable Isotope Lab using a Thermo Finnigan Delta Plus XL isotope ratio mass spectrometer with precision between +/- <0.05%.Samples from 9 stations (92) were analyzed at Hokkaido University using a mass spectrometer. Samples were analyzed December 2007. Barium samples were collected in ~20 ml plastic vials. Once at room temperature the caps were retightened for storage. Barium concentrations were determined at Oregon State University, using isotope-dilution and a VG Thermo Excel Inductively coupled quadrupole mass spectrometer as previously described with minor modifications (Falkner et al., 1994). Dissolved Inorganic Carbon (DIC) and Alkalinity: DIC and Alkalinity were collected into 250 or 500 mL glass bottles. Samples were kept at 4 degree C until analysis and preserved with HgCl2. Alkalinity ("Alkalinity:Total") and DIC ("Carbon:Dissolved:Inorganic") were measured from the same sample bottle at select stations. In addition, more frequent samples of Alkalinity were collected at most stations and have been labelled "Alkalinity:Total:Potentiometric" to distinguish this set of separate samples, even though both sets of Alkalinity samples were measured using potentiometric titration. DIC was analyzed at the Institute of Ocean Sciences using a SOMMA (Single-Operator Multi-Metabolic Analyzer) - Coulometer system to determine DIC. Alkalinity samples were analyzed at the Institute of Ocean Sciences using an automated potentiometric titration system to determine the total alkalinity. Total Chlorophyll-a (>0.7um) samples were collected into 2 L brown Nalgene sample bottles, immediately placed in dark bags and stored in a fridge. Samples were filtered onto 25mm GF/F filters using low vacuum filtration. The filters were put in scintillation vials and either extracted immediately or frozen at -20 degree C until analysis. All samples were analyzed on board. For analysis, 10 ml of 90% acetone was added to the scintillation vial which was then put into a -20 degree C freezer for 24 hours. The samples were allowed to adjust to room temperature for an hour before being read with the fluorometer. Chlorophyll-a and phaeo-pigment levels were measured with a Turner Designs 10 AU-005 Field Fluorometer SN:5152FRXX calibrated with a commercially pure chl-a standard (Sigma). The sample was acidified with 2 drops of 1N hydrochloric acid to obtain the phaeo-pigment reading. Chlorophyll estimates and phaeopigment estimates are calculated following the procedure in JGOFS manual (1994) cited below. Phytoplankton and bacterioplankton were collected in 2 ml capacity cryogenic vial and fixed with 0.2 ml of 10% paraformaldehyde by vortex mixing. Samples were maintained for at least 15 min at laboratory temperature to allow fixation, and then stored at -80 degree C until analysis at the Bedford Institute of Oceanography. Cell concentrations of picophytoplankton, nanophytoplankton, and bacterioplankton (i.e. non-autofluorescent picoplankton) in thawed samples were analyzed by flow cytometry (Becton Dickinson FACSort) following protocols in routine use (Li and Dickie, 2001). Iodine 129 samples were collected into 1 L PVC bottles Samples and returned to the Laboratory of the Atlantic Environmental Radioactivity Unit (AERU) at the Bedford Institute of Oceanography (BIO). In the laboratory, a NaI carrier was added to a 200 mL aliquot of the seawater sample, it was slightly acidified, purified using multiple hexane extractions and iodine was precipitated as NaI. The NaI precipitate was shipped to the IsoTrace Laboratory at the University of Toronto where 129I analyses were performed by accelerator mass spectrometry (Smith et al. 1998; 1999; 2005). Cesium 137 samples were collected into four 10 L plastic carboys from approximately 40 L of seawater. The water samples were passed through a potassium ferrocyanide (KCFC) packed resin column in the laboratory (AERU) which quantitatively extracts 137Cs from seawater (Smith et al. 1990; Smith & Ellis 1995). The KCFC resin was deployed in a standard geometry and measured using a hyperpure Ge detector having an efficiency of 25%. Particulate organic carbon (POC) samples were collected into 2 L Nalgene bottles. Onboard ship, 4 L samples were filtered onto 47 mm GF75 filters that had been pre-combusted at 500 degree C for 4 hours. The filtration was performed within 4 hours of sampling unless otherwise noted. Samples were analyzed at the University of British Columbia. The filters were first dried for 24 hours at 50 degree C, then fumed with HCl for 48 hours, dried again at 50 degree C for 24 hours, and then wrapped in aluminum foil and pressed into pellets. The pellets were run through the CN analyzer where the POC was determined. Total suspended solids samples were collected into 2 L Nalgene bottles. Onboard ship, 4 to 6 L were filtered onto 47 mm 0.4 µm polycarbonate nucleopore filters, that had been rinsed acid cleaned, rinsed with DMQ water, dried at 50 °C and pre-weighed to 0.001 mg. The filters were rinsed with 3% Ammonium carbonate solution after filtration was complete. The filters were then placed in a labeled 50 mm plastic petrie dish and frozen at -20 °C. The filtration was performed within 4 hours of sampling unless otherwise noted. Samples were analyzed at the University of British Columbia. Once in the lab, the TSS samples were dried at 50 °C for 24 hours and then weighed. The TSS concentration was equal to the final weight minus the initial weight divided by the volume of water filtered. References: 1. McLaughlin, F., Proshutinsky, A., Carmack, E.C., Shimada, K., Brown, K., Corkum, M., Dempsey, M., Drost, H., Eert, J., Guay, C., Gueguen, C., Hutchings, J., Itoh, M., Jackson, J., Kane, T., Krishfield, R., Li, B., Lovejoy, C., Maclean, H., Nelson, J., Nelson, R., Orlich, A., Smith, J., Steel, M., White, L., Wrohan, I., and Zimmermann, S. 2017. Physical and chemical data from the Canada Basin July 26 to August 31, 2007. Can. Data Rep. Hydrogr. Ocean Sci. 189: xx + xxx p. (in preparation). 2. Owens, W. B., and R. C. Millard Jr., 1985, A new algorithm for CTD oxygen calibration. J. Physical Oceanography., 15, 621-631. 3. Carpenter, J.H., 1965. The Chesapeake Bay Institute technique for the Winkler dissolved oxygen method, Limnol. Oceanogr., 10, 141-3. 4. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 5. Falkner, K.K., MacDonald, R.W., Carmack, E.C., and Weingartner, T. 1994. The potential of barium as a tracer of Arctic water masses, p. 63-76. In: O.M. Johannessen, R.D. Muench and J.E. Overland [eds.]. The Polar Oceans and Their Role in Shaping the Global Environment: The Nansen Centennial Volume, AGU Geophys. Monograph Series, AGU Books, Washington, DC. 6. Li, W.K.W., and Dickie, P.M. 2001. Monitoring phytoplankton, bacterioplankton, and virioplankton in a coastal inlet (Bedford Basin) by flow cytometry. Cytometry 44: 236-246. 7. Smith, J.N., Ellis, K.M. and Kilius, L.R. 1998. 129I and 137Cs tracer measurementsin the Arctic Ocean. Deep-Sea Research I. 45(6):959-984. 8. Smith, J.N., Ellis, K.M. and Boyd, T.M. 1999. Circulation features in the Central Arctic Ocean revealed by nuclear fuel reprocessing tracers from SCICEX 95 and 96, 1999. Journal of Geophysical Research. 104(C12):29,663-29,677. 9. Smith, J.N., Jones, E.P., Moran, S.B., Smethie Jr., W.M. and Kieser, W.E. 2005. 129I/CFC-11 Transit times for Denmark Strait Overflow Water in the Labrador and Irminger Seas. Journal of Geophysical Research. 110, C05006, doi:10.1029/2004JC002516. 10. Holmes, R.M., Aminot, A., Kérouel, R., Hooker, B.A. and Peterson, B.J. (1999). A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Can. J. Fish. Aquat. Sci., 56: 1801-1808. 11. JGOFS. 1994. Protocols for the Joint Global Ocean Flux Study (JGOFS) core measurements, Manual and guides 29, Scientific Committee on Ocean Research, United Nations Educational, Scientific and Cultural Organization, Paris, 170 pp. . !-1-- ---2--- -3-- --4--- ---5---- ---6---- --7--- ---8--- --9--- --10-- ----11---- ----12---- ---13--- 14 ---15-- --16-- 17 --18- 19 --20- 21 --22-- 23 ---24-- 25 ---26-- 27 --28-- 29 ---30-- 31 --32-- 33 --34-- 35 --36-- 37 ----38---- ----39--- ----40--- !Samp Sample_ Bott Pressu Temperat Salinity Oxygen Fluores Transm Nitrat PAR PAR: Salinity Fl Oxygen: Oxygen Fl Nitra Fl Silic Fl Ammoni Fl Alkalin Fl Chlorop Fl Phaeo- Fl Chlorop Fl Phaeo- Fl Oxygen Fl Barium Fl Bacteria Picophyto Nanophyto !le_ Method le_ re ure : cence: issivi e_ Reference :Bottle ag Dissolv : ag te_ ag ate ag um ag ity: ag hyll: ag Pigmen ag hyll: ag Pigmen ag : ag : ag plankton plankton !Numb Numb Dissol Calibra ty plus_ ~o ed Dissol ~o plus_ ~t ~i ~o Total: ~e Extract ~a t: ~a Extract ~0 t:Extr ~0 Isotop ~p Dissol ~o !er er ved: ted:Sea Nitrit tt ved lv Nitri ri ca ni Potenti tr ed ct Extrac ct ed:0. .3 acted: .3 e:18 e: ved lv ! SBE point e:ISUS le ed te te te um ometric ic ed ted ed 3um um 0.3um um 18 ed !---- ------- ---- ------ -------- -------- ------ ------- ------ ------ ---------- ---------- -------- -- ------- ------ -- ----- -- ----- -- ------ -- ------- -- ------- -- ------ -- ------- -- ------ -- ------ -- ------ -- ---------- --------- --------- *END OF HEADER 221 UN 24 7.2 0.2168 26.2683 8.90 0.043 89.86 0.000 0.000 215.360 26.6390 0 9.197 410.72 0 0.0 0 2.4 0 0.00 0 1928.80 0 0.026 0 0.01 0 0.020 0 0.01 0 -3.60 0 70.0 0 176560.00 2381.00 153.00 220 UN 23 22.9 -0.7645 27.2026 9.20 0.048 89.95 0.000 0.000 228.820 27.3355 0 8.978 400.97 0 0.0 0 2.5 0 0.00 0 1971.40 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -3.53 0 69.0 0 165677.00 2975.00 157.00 219 UN 22 72.2 -0.8393 31.6050 8.00 0.301 89.78 0.000 0.000 196.130 31.6370 0 7.904 352.98 0 5.1 0 10.2 0 0.00 0 2188.70 0 0.222 0 0.45 0 0.187 0 0.34 0 -1.92 0 60.0 0 120700.00 4699.00 383.00 218 UN 21 112.7 -1.2565 32.3950 7.02 0.043 90.32 0.000 0.000 138.440 32.4211 0 6.992 312.25 0 12.4 0 25.4 0 0.00 0 -99.00 0 0.017 0 0.01 0 0.012 0 0.00 0 -1.67 0 69.0 0 78767.00 16.00 42.00 217 UN 20 135.3 -1.3914 32.6720 6.75 0.038 90.34 0.000 0.000 214.320 32.6964 0 6.639 296.50 0 14.4 0 30.4 0 0.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -1.54 0 69.0 0 79718.00 -99.00 -99.00 216 UN 19 158.7 -1.5097 32.9585 6.60 0.039 90.32 0.000 0.000 212.840 33.0201 0 6.524 291.36 0 15.6 0 34.8 0 0.01 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 215 UN 18 174.0 -1.4747 33.2131 6.45 0.039 90.33 0.000 0.000 204.120 33.2564 0 6.347 283.47 0 15.9 0 35.5 0 0.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -1.39 0 68.0 0 -99.00 -99.00 -99.00 214 UN 17 189.6 -1.3477 33.5733 6.25 0.038 90.32 0.000 0.000 209.590 33.5738 0 6.207 277.20 0 15.5 0 32.6 0 0.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -1.09 0 64.0 0 90525.00 -99.00 -99.00 213 UN 16 199.5 -1.2698 33.8143 6.26 0.038 90.35 0.000 0.000 215.360 33.8104 0 6.201 276.93 0 14.5 0 27.3 0 0.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 212 UN 15 215.5 -1.0134 34.1299 6.47 0.038 90.37 0.000 0.000 221.130 34.1179 0 6.412 286.37 0 12.3 0 16.1 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -0.49 0 49.0 0 64954.00 -99.00 -99.00 211 UN 14 252.3 -0.2537 34.4371 6.65 0.036 90.38 0.000 0.000 195.690 34.4319 0 -99.000 -99.00 0 11.6 0 9.0 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -0.07 0 45.0 0 47869.00 -99.00 -99.00 210 UN 13 289.3 0.2410 34.6346 6.64 0.034 90.39 0.000 0.000 165.360 34.6380 0 -99.000 -99.00 5 12.4 0 8.5 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 0.03 0 43.0 0 44026.00 -99.00 -99.00 209 UN 12 318.4 0.3867 34.7101 6.63 0.034 90.41 0.000 0.000 159.600 34.7077 0 6.603 294.88 0 13.0 0 9.0 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 208 UN 11 331.2 0.4923 34.7525 6.71 0.034 90.41 0.000 0.000 161.520 34.7518 0 6.663 297.57 0 12.7 0 7.6 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 0.10 0 -99.0 0 73288.00 -99.00 -99.00 207 UN 10 412.5 0.6257 34.8212 6.78 0.034 90.43 0.000 0.000 134.600 34.8211 0 6.794 303.41 0 13.0 0 7.1 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 206 UN 9 459.0 0.5484 34.8256 6.76 0.033 90.44 0.000 0.000 136.670 34.8252 0 6.748 301.35 0 13.2 0 7.6 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 205 UN 8 509.6 0.5101 34.8402 6.80 0.033 90.44 0.000 0.000 136.520 34.8393 0 6.812 304.22 0 13.1 0 7.1 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 204 UN 7 609.7 0.4055 34.8560 6.83 0.034 90.44 0.000 0.000 144.210 34.8551 0 6.814 304.30 0 13.3 0 7.5 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 203 UN 6 814.1 0.1730 34.8737 6.88 0.035 90.47 0.000 0.000 159.600 34.8733 0 6.909 308.57 0 13.2 0 7.3 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 202 UN 5 1016.4 -0.0355 34.8872 6.90 0.035 90.47 0.000 0.000 173.050 34.8875 0 6.891 307.75 0 13.2 0 7.7 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 201 UN 4 1504.0 -0.3276 34.9200 6.87 0.035 90.50 0.000 0.000 135.340 34.9196 0 6.897 308.01 0 13.9 0 9.5 0 0.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 200 UN 3 2034.8 -0.4081 34.9464 6.69 0.034 90.48 0.000 0.000 129.130 34.9463 0 6.695 298.98 0 14.7 0 12.3 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 0.31 0 -99.0 0 64117.00 -99.00 -99.00 199 UN 2 2544.8 -0.3721 34.9562 6.58 0.034 90.43 0.000 0.000 115.070 34.9575 0 6.576 293.69 0 15.2 3 14.1 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00 198 UN 1 2787.2 -0.3478 34.9577 6.56 0.033 90.44 0.000 0.000 101.910 34.9584 0 6.543 292.21 0 15.2 3 14.5 0 -99.00 0 -99.00 0 -99.000 0 -99.00 0 -99.000 0 -99.00 0 -99.00 0 -99.0 0 -99.00 -99.00 -99.00