*2014/11/20 09:55:46.15 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2007/09/09 10:04:42.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 7444FB52 NUMBER OF CHANNELS : 21 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 9444 9444 2 Pressure decibar 7.394 7.394 3 Temperature:Secondary 'deg C (ITS90)' 9.5321 9.5321 4 Transmissivity %/metre 48.5 48.5 5 Fluorescence:URU:Seapoint mg/m^3 0.787 0.787 6 Oxygen:Dissolved:SBE mL/L 4.484 4.484 7 Oxygen:Dissolved:SBE umol/kg 195.3951 195.3951 8 PAR uE/m^2/sec 0.83E-01 0.83E-01 9 Salinity:T1:C1 PSS-78 31.7369 31.7369 10 Bottle_Number n/a 1 1 11 Number_of_bin_records n/a 121 121 12 Salinity:Bottle PSS-78 31.7243 31.7243 13 Flag:Salinity:Bottle n/a 14 Chlorophyll:Extracted mg/m^3 1.72 1.72 15 Flag:Chlorophyll:Extracted n/a 16 Nitrate_plus_Nitrite umol/L 22.3 22.3 17 Flag:Nitrate_plus_Nitrite n/a 18 Silicate umol/L 40.2 40.2 19 Flag:Silicate n/a 20 Phosphate umol/L 1.9 1.9 21 Flag:Phosphate n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 7 F ' ' 2 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 7 F ' ' 1 9 -99 ' ' 9 F ' ' 4 10 -99 ' ' 3 I I 0 11 ' ' ' ' 5 I I 0 12 -99 ' ' 9 F R4 4 13 0 ' ' 3 NQ C ' ' 14 -99 ' ' 7 F R4 2 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' 6 F R4 1 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' 6 F R4 1 19 0 ' ' 3 NQ C ' ' 20 -99 ' ' 7 F R4 2 21 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2007-16 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : La Perouse SCIENTIST : Yelland D. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI STATION : CPE1 EVENT NUMBER : 126 LATITUDE : 50 59.98000 N ! (deg min) LONGITUDE : 127 50.08000 W ! (deg min) WATER DEPTH : 145 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2106 conductivity:primary ' ' 2424 pressure ' ' 63507 temperature:secondary ' ' 4752 conductivity:secondary ' ' 1763 Fluorometer ' ' Seapoint transmissometer:primary ' ' 953DR Oxygen:SBE ' ' 1119 altimeter: ' ' ' ' irradiance:primary ' ' 4656 $END $REMARKS SOFTWARE VERSION SEASAVE V 7.12 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SBE_IOS 3.1 2008/03/19 10:54:48 121 121 ADDSAMP 3.4 2008/03/21 14:31:17 121 121 BINAVE 4.1.1 2008/03/21 14:31:58 121 1 MERGE 3.3 2008/04/17 16:51:02 1 1 CLEAN 5.0.2 2008/04/17 16:51:07 ? ? CALIB 11.7 2008/04/17 16:52:02 1 1 SORT 3.5 2008/04/17 16:52:09 1 1 REMOVECH 8.0 2008/04/17 16:52:21 1 1 CHGUNITS 3.0 2008/04/17 16:52:56 1 1 REORDER 1.2.1 2008/04/17 16:53:03 ? ? HDREDIT2 2.5.1 2008/04/17 16:53:26 ? ? HDREDIT2 2.5.1 2010/08/13 13:57:54 ? ? CHANGE_FLAGS 1.0 2013/07/16 16:32:59 1 1 HDREDIT2 2.6 2013/12/16 13:07:49 ? ? CHANGE_FLAGS 2.0 2014/11/20 09:55:46 1 1 $END $REMARKS -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data_Processing\2007-16\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2008/04/17 16:50:57 2008/04/17 16:50:57 2008/04/17 16:50: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Ammonium, Flag:Ammonium Primary file : Q:\Cruise_Data_Processing\2007-16\Processing\hydro\2007-16-0126.samavg Secondary file: Q:\Cruise_Data_Processing\2007-16\Processing\hydro\2007-16-0126.mrgcln1 -CLEAN functions: 2008/04/17 16:51:04 20 Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2008/04/17 16:52:02 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data_Processing\2007-16\Processing\doc\2007-16-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Oxygen:Dissolved:SBE mL/L 10 0.9500000E-02 0.1078700E+01 -SORT parameters: 2008/04/17 16:52:09 Sorted in ascending order of channel Press* -REMOVECH 2008/04/17 16:52:21 10 channels removed. -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -HEADER EDITS: 2008/04/17 16:53:26 Applied edit header: Q:\Cruise_Data_Processing\2007-16\Processing\doc\2007-16-bot-hdr2.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F11.2 ==> F7.1 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 8: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 12: Salinity:Bottle [PSS-78] Units: ==> PSS-78 -HEADER EDITS: 2010/08/13 13:57:54 Applied edit header: C:\My Documents\PROCESSING NOTES\sample headers\fixhdr.txt Channel 4: Transmissivity [%/metre] Format: F6.1 ==> F7.2 -HEADER EDITS: 2013/12/16 13:07:49 Channel 13: Flag:Salinity:Bottle [n/a] Units: ==> n/a Channel 15: Flag:Chlorophyll:Extracted [n/a] Units: ==> n/a Channel 17: Flag:Nitrate_plus_Nitrite [n/a] Units: ==> n/a Channel 19: Flag:Silicate [n/a] Units: ==> n/a Channel 21: Flag:Phosphate [n/a] Units: ==> n/a $END *COMMENTS Salinity sample #9444 was originally called 444 but that was a repeat of an earlier sample. Sample_Number 9444: Mis-sampled because not a surface value for nutrients Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed at IOS on Guildline model 8400B Autosal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed at sea on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples for this cast were stored frozen and analyzed at IOS using the Technicon II Autoanalyzer. Chlorophyll samples are collected in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs Model 10 fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. Chlorophyll samples were analyzed on board ship. Ammonium analyses at IOS follows the methods described in: Holmes, R.M., Aminot, A., Kerouel, R., Hooker, B.A., and Peterson, B.J. 1999 A simple and precise method for measuring ammonium in marine and freshwater ecosystems. Can. J. Fish. Aquat. Sci. 56: 1801-1808 References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.95E-02 1.0787) $END !-1-- --2--- ---3---- --4--- ---5--- --6--- --7-- --8--- ---9---- 10 -11- ---12--- 13 --14-- 15 --16- 17 --18- 19 --20-- 21 !Samp Pressu Temperat Transm Fluores Oxygen Oxyge PAR Salinity Bo Numb Salinity Fl Chloro Fl Nitra Fl Silic Fl Phosph Fl !le_ re ure: issivi cence: : n: :T1:C1 tt er_o :Bottle ag phyll: ag te_ ag ate ag ate ag !Numb Secondar ty URU: Dissol Disso ~u ~bin ~o Extrac ~a plus_ ~t ~i ~p !er y Seapoin ved: lved: mb _rec tt ted ct Nitri ri ca ha ! t SBE SBE er ords le ed te te te te !---- ------ -------- ------ ------- ------ ----- ------ -------- -- ---- -------- -- ------ -- ----- -- ----- -- ------ -- *END OF HEADER 9444 7.4 9.5321 48.50 0.787 4.48 195.4 0.1 31.7369 1 121 31.7243 0 1.72 0 22.3 4 40.2 4 1.90 4