*2013/07/16 09:55:30.64 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2007/06/01 21:47:00.000 NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII NUMBER OF CHANNELS : 8 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------------------- -------- -------------- -------------- 1 Sample_Order n/a 69 69 2 Sampler_Type n/a 3 Sample_Number n/a 11 11 4 Depth metres 10 10 5 Iron:Unfiltered:StrongAcid:MV nmol/L 0.84 0.84 6 Flag:Iron:Unfiltered:StrongAcid:MV n/a 7 Iron:Filtered:StrongAcid:MV:0.22 nmol/L 0.79 0.79 8 Flag:Iron:Filtered:StrongAcid:MV:0.22 n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I4 I ' ' 2 ' ' ' ' 8 ' ' C ' ' 3 -99 ' ' ' ' I4 I ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' 5 -99 ' ' ' ' F7.2 R4 ' ' 6 ' ' ' ' 7 NQ C ' ' 7 -99 ' ' ' ' F7.2 R4 ' ' 8 ' ' ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2007-13 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION STATION : P26 EVENT NUMBER : 8011 LATITUDE : 50 0.00000 N ! (deg min) LONGITUDE : 145 0.00000 W ! (deg min) *INSTRUMENT TYPE : Bottle MODEL : Sampler_Type $REMARKS Sampler_Type described in the data record $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2013/06/11 10:56:04 1 1 HDREDIT2 2.6 2013/06/11 11:01:24 ? ? CHANGE_FLAGS 1.0 2013/07/16 09:55:30 1 1 $END $REMARKS -HEADER EDITS: 2013/06/11 11:01:24 Applied edit header: O:\Data Processing\Header Comments\Work\2007-13-Iron.txt $END *COMMENTS Sample_Number 11: 3: large rep spread, only lowest value reported Note that there appeared to be a problem with contamination in numerous samples - likely due to inexperience in sampling for ultra-trace metals, compounded with possible filter or bottle contamination. The bottle had been tested in Saanich Inlet, which would create massive contamination. For Collection and Analysis Methods, and Explanation of Abbreviations please see the Metadata Sheet in the Iron Spreadsheet file located in the Cruise .DOC directory. !-1- ---2--- -3- --4--- --5--- --6--- --7--- 8 !Sam Sampler Sam Depth Iron: Flag:I Iron:F F !ple _Type ple Unfilt ron:Un iltere l !_ _ ered:S ~red:S ~trong ~ !Ord Num trongA trongA Acid:M 2 !er ber cid:MV cid:MV V:0.22 2 !--- ------- --- ------ ------ ------ ------ - *END OF HEADER 69 XN 11 10.0 0.84 36 0.79 3