*2014/11/20 09:55:15.28 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2006/07/27 02:39:12.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 5820F934 NUMBER OF CHANNELS : 12 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Bottle_Number n/a 1 7 2 Pressure decibar 1.89 105.7 3 Temperature:Secondary 'deg C (ITS90)' 7.949 11.2479 4 Transmissivity %/metre 20.4 45.8 5 Fluorescence:URU:Seapoint mg/m^3 0.168 6.724 6 Oxygen:Dissolved:SBE mL/L 2.312 6.384 7 Oxygen:Dissolved:SBE umol/kg 100.6116 278.2602 8 Salinity:T1:C1 PSS-78 31.7739 33.2003 9 Sample_Number n/a 48 54 10 Number_of_bin_records n/a 121 121 11 Oxygen:Dissolved mL/L 2.47 6.441 12 Flag:Oxygen:Dissolved n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 5 I I 0 10 ' ' ' ' 5 I I 0 11 -99 ' ' 8 F ' ' 3 12 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2006-24 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : WCVI SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI STATION : EFF16 EVENT NUMBER : 4 LATITUDE : 48 47.65000 N ! (deg min) LONGITUDE : 125 16.00000 W ! (deg min) ALTIMETER (M) : 7.11 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2399 pressure ' ' 75636 temperature:secondary ' ' 2038 conductivity:secondary ' ' 2754 Fluorometer ' ' Seapoint transmissometer:primary ' ' 498DR Oxygen:SBE ' ' 0047 altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.29B $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.0 2006/12/01 14:53:26 847 847 ADDSAMP 3.4 2006/12/03 14:25:08 847 847 BINAVE 4.1.1 2006/12/03 14:25:43 847 7 MERGE 3.3 2006/12/03 14:43:08 7 7 CLEAN 5.0 2006/12/05 11:51:34 ? ? CALIB 11.7 2006/12/08 09:26:44 7 7 SORT 3.5 2006/12/08 09:27:28 7 7 REMOVECH 7.0 2006/12/08 09:27:36 7 7 CHGUNITS 3.0 2006/12/08 09:32:11 7 7 REORDER 1.2.1 2006/12/08 09:32:20 ? ? HDREDIT2 2.5.1 2006/12/08 09:54:33 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:30:21 7 7 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:32:38 7 7 CHANGE_FLAGS 2.0 2014/11/20 09:55:15 7 7 $END $REMARKS -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2006-24\ctd\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2006/12/03 14:43:08 2006/12/03 14:43:08 2006/12/03 14:43: Merge Channel: Bottle_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : Q:\Cruise_Data\2006-24\CTD\hydro\2006-24-0004.samavg Secondary file: Q:\Cruise_Data\2006-24\CTD\hydro\2006-24-0004.mrgcln1 -CLEAN functions: 2006/12/05 11:51:34 20 Remove Sea-Bird comments from the header. Remove remark heading: "Comments from secondary" -CALIB parameters: 2006/12/08 09:26:44 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2006-24\CTD\doc\2006-24-recal1-bot.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 3 Pressure dbars 10 0.1200000E+01 0.1000000E+01 11 Oxygen:Dissolved:SBE mL/L 10 0.6800000E-01 0.1008700E+01 15 Salinity:T1:C1 PSS-78 10 -0.9000000E-03 0.1000000E+01 -SORT parameters: 2006/12/08 09:27:28 Sorted in ascending order of channel Pressure -REMOVECH 2006/12/08 09:27:36 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Descent_Rate [m/s] Salinity:T0:C0 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE [mL/L]' changed from mL/L to umol/kg -HEADER EDITS: 2006/12/08 09:54:33 Applied edit header: Q:\Cruise_Data\2006-24\CTD\doc\2006-24-bot-hdr.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 $END *COMMENTS Sample #53: A salinity sample was taken, but the value was not included in spreadsheet received from analyst. The value on the analysis sheet differed from the CTD value by 0.4psu, so it is presumed there was something wrong with the sample. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Pressure dbars 10 -99 () (1.2 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0.68E-01 1.0087) Salinity:T1:C1 PSS-78 10 -99 () (-0.9E-03 1) $END !1- --2--- ---3---- --4-- ---5--- --6--- --7-- ---8---- -9-- -10- ---11-- - !Bo Pressu Temperat Trans Fluores Oxygen Oxyge Salinity Samp Numb Oxygen: F !tt re ure: missi cence: : n: :T1:C1 le_ er_o Dissolv l !~u Secondar vity URU: Dissol Disso Numb ~bin ed ~ !mb y Seapoin ved: lved: er _rec e !er t SBE SBE ords d !-- ------ -------- ----- ------- ------ ----- -------- ---- ---- ------- - *END OF HEADER 7 1.9 11.2479 20.4 6.724 6.38 278.3 31.7739 54 121 6.441 0 6 11.4 11.0682 27.2 4.702 5.45 237.7 31.7756 53 121 5.750 0 5 20.2 10.4560 36.2 3.165 4.74 206.5 31.9066 52 121 4.846 0 4 30.7 9.8931 44.0 1.741 4.15 180.9 32.0851 51 121 4.162 0 3 49.5 8.7137 45.8 0.312 2.89 125.7 32.7196 50 121 2.949 0 2 76.6 8.1988 37.8 0.175 2.46 107.0 33.0249 49 121 2.520 0 1 105.7 7.9490 30.5 0.168 2.31 100.6 33.2003 48 121 2.470 0