*2014/11/20 09:54:59.70 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2005/10/02 13:33:00.000 NUMBER OF RECORDS : 9 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 PAD : -99 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------------- --------- -------------- -------------- 1 Sample_Number n/a ' ' ' ' 2 Pressure decibar ' ' ' ' 3 Oxygen:Dissolved mL/L ' ' ' ' 4 Flag:Oxygen:Dissolved n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 ' ' ' ' 2 NQ C ' ' $END $REMARKS Raw data in file oxydata\2005-30-\2005-30-0002.o2 VIO3 = 10.00 ! Volume of iodate standard (cm**) NIO3 = .01012964 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) $END *ADMINISTRATION MISSION : 2005-30 AGENCY : IOS, Ocean Sciences Division, Sidney COUNTRY : Canada PROJECT : Broughton Oceanography & Circulation SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : QCS /Knight Inlet / Kingcome Inlet / Broughton Arch. STATION : Kn 2 EVENT NUMBER : 2 LATITUDE : 50 39.28000 N ! (deg min) LONGITUDE : 126 11.25000 W ! (deg min) WATER DEPTH : 188 *INSTRUMENT TYPE : Brinkman Dosimat and Colorimeter MODEL : 665/910 $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 3.0 2005-10-02 13:33 ' ' 9 ADDCHANS 1.2 2005/10/11 10:10:00 ? ? REMOVECH 7.0 2006/01/30 16:45:05 9 9 HDREDIT2 2.5.1 2006/01/31 09:57:13 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:32:18 9 9 CHANGE_FLAGS 2.0 2014/11/20 09:54:59 9 9 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -REMOVECH 2006/01/30 16:45:05 The following CHANNEL(S) were removed: Thiosulfate_titer [cm**3] Flask_Number Flask_Volume [cm**3] Blank [cm**3] Standard [cm**3] -HEADER EDITS: 2006/01/31 09:57:13 Applied edit header: Q:\Cruise_Data\2005-30\CTD\doc\2005-30-hdr-oxy.txt Channel 1: Sample_Number [n/a] Format: F6.0 ==> I5 Pad: ' ' ==> -99 Channel 2: Pressure [decibar] Units: DBARS ==> decibar Format: F8.1 ==> F7.1 Pad: ' ' ==> -99 Channel 3: Oxygen:Dissolved [mL/L] Pad: ' ' ==> -99 $END *COMMENTS Nominal pressures were replaced by calculated ones based on pressures at which the CTD stopped for addition or removal of bottles. !-1-- --2--- ---3--- 4 !Samp Pressu Oxygen: F !le_ re Dissolv l !Numb ed ~ !er e ! d !---- ------ ------- - *END OF HEADER 3 0.1 6.942 0 4 9.1 3.826 0 5 18.8 3.692 0 6 27.8 3.541 0 7 47.6 3.326 0 8 71.6 3.170 0 9 95.3 2.932 0 10 118.6 2.759 0 11 142.6 2.762 0