*2014/11/20 09:54:57.39 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2005/10/02 05:22:21.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII CRC : 8B6FE7A4 NUMBER OF CHANNELS : 12 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 6 6 2 Pressure decibar 151.17 151.17 3 Temperature:Primary 'deg C (ITS90)' 7.046 7.046 4 Transmissivity %/metre 53 53 5 Fluorescence:URU:Seapoint mg/m^3 0.66E-01 0.66E-01 6 Oxygen:Dissolved:SBE mL/L 1.72 1.72 7 Oxygen:Dissolved:SBE umol/kg 74.79967 74.79967 8 Salinity:T0:C0 PSS-78 33.9068 33.9068 9 Bottle_Number n/a 1 1 10 Number_of_bin_records n/a 121 121 11 Salinity:Bottle PSS-78 33.9093 33.9093 12 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 6 F ' ' 1 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 3 I I ' ' 10 ' ' ' ' 5 I I 0 11 -99 ' ' ' ' F9.4 R4 ' ' 12 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-23 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : LaPerouse, ECOHAB, PERD, Aquaculture SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : JdeF/WCVI/Knight Inlet STATION : JF2-4 EVENT NUMBER : 10 LATITUDE : 48 21.31000 N ! (deg min) LONGITUDE : 124 14.98000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 4484 conductivity:primary ' ' 3038 pressure ' ' 63507 temperature:secondary ' ' 2106 conductivity:secondary ' ' 1729 Fluorometer ' ' Seapoint transmissometer:primary ' ' 498DR Oxygen:SBE ' ' 0766 altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.35 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 3.0 2006/03/27 17:23:08 121 121 CLEAN 4.8.1 2006/03/27 17:23:50 ? ? ADDSAMP 3.4 2006/03/28 11:01:46 121 121 BINAVE 4.1 2006/03/28 11:02:35 121 1 MERGE 3.3 2006/03/28 11:14:22 1 1 MERGE 3.3 2006/03/28 11:23:48 1 1 CALIB 11.7 2006/03/31 11:45:51 1 1 CLEAN 4.8.1 2006/03/31 13:48:45 ? ? SORT 3.5 2006/03/31 13:48:49 1 1 REMOVECH 7.0 2006/03/31 13:49:16 1 1 CHGUNITS 2.1 2006/03/31 13:54:50 1 1 REORDER 1.2.1 2006/03/31 13:55:11 ? ? HDREDIT2 2.5.1 2006/03/31 13:57:33 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:30:10 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:32:15 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:54:57 1 1 $END $REMARKS -CLEAN functions: 2006/03/27 17:23:49 20 Change Pad Value to -99 in Channel: Oxygen:Dissolved:SBE [mL/L] Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2005-23\CTD\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2006/03/28 11:14:20 2006/03/28 11:14:20 2006/03/28 11:14: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2005-23\CTD\hydro\2005-23-0010.samavg Secondary file: Q:\Cruise_Data\2005-23\CTD\hydro\2005-23-0010.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-23\ctd\hydro\2005-23-0010.mrg1 Secondary file: Q:\Cruise_Data\2005-23\ctd\hydro\2005-23-0010.add -CALIB parameters: 2006/03/31 11:45:51 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2005-23\CTD\doc\2005-23-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Oxygen:Dissolved:SBE mL/L 10 0.6920000E-01 0.1403800E+01 -CLEAN functions: 2006/03/31 13:48:45 20 Change Pad Value to -99 in Channel: Oxygen:Dissolved:SBE [mL/L] Remove Sea-Bird comments from the header. -SORT parameters: 2006/03/31 13:48:49 Sorted in ascending order of channel Pressure -REMOVECH 2006/03/31 13:49:16 The following CHANNEL(S) were removed: Scan_Number Temperature:Secondary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Descent_Rate [m/s] Status:Pump Salinity:T1:C1 [PSS-78] Flag -CHANGE units: 'Oxygen:Dissolved:SBE' changed from mL/L to umol/kg -HEADER EDITS: 2006/03/31 13:57:33 Applied edit header: Q:\Cruise_Data\2005-23\CTD\doc\2005-23-BOT-HDR.TXT Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8400 Autosal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.692E-01 1.4038) $END !-1-- --2--- ---3---- --4-- ---5--- --6--- --7-- ---8---- 9- -10- ---11--- - !Samp Pressu Temperat Trans Fluores Oxygen Oxyge Salinity Bo Numb Salinity F !le_ re ure: missi cence: : n: :T0:C0 tt er_o :Bottle l !Numb Primary vity URU: Dissol Disso ~u ~bin ~ !er Seapoin ved: lved: mb _rec l ! t SBE SBE er ords e !---- ------ -------- ----- ------- ------ ----- -------- -- ---- -------- - *END OF HEADER 6 151.2 7.0460 53.0 0.066 1.72 74.8 33.9068 1 121 33.9093 0