*2018/07/06 08:50:15.47 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2005/05/03 09:22:58.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 9 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 9 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 901 909 2 Pressure decibar 498.478 499.887 3 Temperature:Secondary 'deg C (ITS90)' 4.9504 4.9582 4 Transmissivity %/metre 59 59 5 Oxygen:Dissolved:SBE mL/L 0.792758 0.792758 6 Fluorescence:URU:Seapoint mg/m^3 0.61E-01 0.64E-01 7 Salinity:T1:C1 PSS-78 34.1208 34.122 8 Bottle_Number n/a 1 9 9 Number_of_bin_records n/a 53 120 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I ' ' 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 7 F ' ' 2 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 3 I I ' ' 9 -99 ' ' 5 I I 0 $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-08 AGENCY : IOS, Ocean Sciences Division, Sidney, BC COUNTRY : Canada PROJECT : LaPerouse,JdeF,BIO,Sill,ECOHAB,Aquaculture SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : SoG,JdeF,WCVI STATION : LC09 EVENT NUMBER : 114 LATITUDE : 48 25.94000 N ! (deg min) LONGITUDE : 126 13.68000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2449 conductivity:primary ' ' 2102 pressure ' ' 63507 temperature:secondary ' ' 2968 conductivity:secondary ' ' 1729 Fluorometer ' ' Seapoint transmissometer:primary ' ' 333DR Oxygen:SBE ' ' 0766 altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.32 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------ ------ ---------- -------- --------- --------- SBE_IOS 2.9 2005/07/12 11:03:21 584 584 CLEAN 4.8 2005/07/12 11:05:33 ? ? ADDSAMP 3.4 2005/07/15 12:56:14 584 584 BINAVE 4.1 2005/07/15 12:56:44 584 9 MERGE 3.3 2005/07/29 12:46:16 9 9 MERGE 3.3 2005/07/29 12:55:20 9 9 CALIB 11.5 2005/08/05 14:11:07 9 9 CLEAN 4.8 2005/08/05 16:57:04 ? ? SORT 3.5 2005/08/05 16:57:53 9 9 REMOVECH 7.0 2005/08/05 16:58:20 9 9 HDREDIT2 2.5 2005/08/05 17:05:30 ? ? HDREDIT2 2.5 2005/08/17 11:12:26 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:30:01 9 9 CLEAN 5.2.3 2018/07/06 08:50:15 ? ? $END $REMARKS -CLEAN functions: 2005/07/12 11:05:11 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2005-08\CTD\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-08\CTD\hydro\2005-08-0114.samavg Secondary file: Q:\Cruise_Data\2005-08\CTD\hydro\2005-08-0114.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-08\CTD\hydro\2005-08-0114.mrg1 Secondary file: Q:\Cruise_Data\2005-08\CTD\hydro\2005-08-0114.add -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2005-08\CTD\hydro\2005-08-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Oxygen:Dissolved:SBE mL/L 10 0.1110000E+00 0.1463000E+01 16 Salinity:T1:C1 PSS-78 10 -0.1000000E-02 0.1000000E+01 -CLEAN functions: 2005/08/05 16:57:03 20 Remove Sea-Bird comments from the header. -SORT parameters: 2005/08/05 16:57:53 Sorted in ascending order of channel Pressure -REMOVECH 2005/08/05 16:58:20 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Oxygen:Voltage:SBE [volts] Altimeter [metres] Descent_Rate [m/s] Status:Pump Salinity:T0:C0 [PSS-78] Flag -HEADER EDITS: 2005/08/05 17:05:30 Applied edit header: Q:\Cruise_Data\2005-08\CTD\doc\2005-08-bot-hdr.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 6: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 5: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 -HEADER EDITS: 2005/08/17 11:12:26 Applied edit header: O:\Data Processing\Header Comments\Agency_OSD.txt -CLEAN functions: 2018/07/06 08:50:14 20 Change Pad Value to -99 in All Channels. $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed frozen using a Technicon AAII autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.111 1.463) Salinity:T1:C1 PSS-78 10 -99 () (-0.1E-02 1) $END !-1-- --2--- ---3---- --4-- --5--- ---6--- ---7---- 8- -9-- !Samp Pressu Temperat Trans Oxygen Fluores Salinity Bo Numb !le_ re ure: missi : cence: :T1:C1 tt er_o !Numb Secondar vity Dissol URU: ~u ~bin !er y ved: Seapoin mb _rec ! SBE t er ords !---- ------ -------- ----- ------ ------- -------- -- ---- *END OF HEADER 901 498.5 4.9582 59.0 0.79 0.061 34.1208 1 57 908 499.0 4.9563 59.0 0.79 0.063 34.1212 8 62 905 499.1 4.9555 59.0 0.79 0.062 34.1213 5 57 906 499.2 4.9559 59.0 0.79 0.062 34.1212 6 60 902 499.3 4.9566 59.0 0.79 0.062 34.1212 2 53 909 499.5 4.9530 59.0 0.79 0.062 34.1217 9 120 907 499.5 4.9541 59.0 0.79 0.063 34.1214 7 56 904 499.5 4.9514 59.0 0.79 0.062 34.1217 4 57 903 499.9 4.9504 59.0 0.79 0.064 34.1220 3 62