*2021/09/07 10:16:02.64 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2005/10/07 22:33:16.000 TIME INCREMENT : 0 0 0 0.125 0 ! (day hr min sec ms) NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Rosette + CTD:Up FILE TYPE : ASCII CRC : 6EC33730 NUMBER OF CHANNELS : 25 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 224 230 2 Bottle:Position n/a 1 7 3 Bottle_Number n/a 1 7 4 Pressure decibar 4.519 72.459 5 Depth metres 4.473 71.709 6 Temperature:Primary 'deg C (ITS90)' -1.3641 2.825 7 Conductivity:Primary S/m 2.624225 2.86529 8 Transmissivity %/metre 11.7 36.4 9 Fluorescence:URU:Seapoint mg/m^3 0.475 1.263 10 Salinity:T0:C0 PSS-78 31.1069 32.7107 11 Oxygen:Dissolved:SBE mL/L 7.165 7.679 12 Oxygen:Dissolved:SBE umol/kg 311.6664 334.3246 13 Number_of_bin_records n/a 81 81 14 Salinity:Bottle PSS-78 31.1115 32.712 15 Flag:Salinity:Bottle ' ' 16 Oxygen:Dissolved mL/L 7.156 7.696 17 Flag:Oxygen:Dissolved ' ' 18 Barium:Dissolved nmol/L 54.7 105.9 19 Flag:Barium:Dissolved ' ' 20 Nitrate_plus_Nitrite umol/L 0.1 8.4 21 Flag:Nitrate_plus_Nitrite ' ' 22 Silicate umol/L 4.2 26.9 23 Flag:Silicate ' ' 24 Phosphate umol/L 0.71 2.08 25 Flag:Phosphate ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 3 I I ' ' 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 7 F ' ' 1 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 10 F ' ' 6 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 8 F ' ' 3 10 -99 ' ' 9 F ' ' 4 11 -99 ' ' 7 F ' ' 2 12 -99 ' ' 6 F ' ' 1 13 ' ' ' ' 5 I I 0 14 -99 ' ' 9 F R4 4 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' ' ' F8.3 R4 ' ' 17 0 ' ' 3 NQ C ' ' 18 -99 ' ' ' ' F7.1 R4 ' ' 19 0 ' ' 3 NQ C ' ' 20 -99 ' ' 7 F R4 2 21 0 ' ' 3 NQ C ' ' 22 -99 ' ' 7 F R4 2 23 0 ' ' 3 NQ C ' ' 24 -99 ' ' 7 F R4 2 25 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ---------------------------------------------------------------------------------- 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-006 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : JWACS-2005 SCIENTIST : van Hardenberg B. PLATFORM : Sir Wilfrid Laurier *LOCATION GEOGRAPHIC AREA : Beaufort Sea / Chukchi Sea STATION : BCH-04 EVENT NUMBER : 43 LATITUDE : 71 6.27400 N ! (deg min) LONGITUDE : 159 21.28800 W ! (deg min) WATER DEPTH : 84 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 0293 $TABLE: SENSORS ! Name Abs Depth Serial No ! --------------------------------- -------------- ---------- Temperature ' ' 034115 Conductivity ' ' 042607 'Pressure:Strain Gauge' ' ' 290464 'Oxygen:SBE 43' ' ' 43-0615 'User Polynomial' ' ' ' ' Fluorometer:Seapoint ' ' 2336 Transmissometer:Chelsea/Seatech ' ' SeaTech $END $REMARKS Software Version Seasave Win32 V 5.33 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.2.3 2020/08/19 14:11:46 567 567 CLEAN 5.2.4 2020/08/19 14:14:12 567 567 ADDSAMP 3.6 2020/08/20 11:33:50 567 567 BINAVE 4.2.1 2020/08/20 11:34:18 567 7 MERGE 3.5.1 2020/08/20 14:24:49 7 7 CLEAN 5.2.4 2020/08/31 16:34:50 7 7 CALIB 12.0.1 2020/08/31 16:35:11 7 7 SORT 3.6 2020/08/31 16:35:18 7 7 REMOVECH 8.2 2020/08/31 16:35:57 7 7 CHGUNITS 3.1.2 2020/08/31 16:36:09 7 7 REORDER 1.3.1 2020/08/31 16:36:18 ? ? HDREDIT2 3.2 2020/08/31 16:36:43 ? ? HDREDIT2 3.2 2021/09/07 10:16:02 ? ? $END $REMARKS -CLEAN functions: 2020/08/19 14:14:08 20 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: D:\Telework\2005-006\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2020/08/20 14:24:49 Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Barium:Dissolved, Flag:Barium:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate Primary file : D:\Telework\2005-006\Processing\hydro\2005-006-0043.samavg Secondary file: D:\Telework\2005-006\Processing\hydro\2005-006-0043.mrg1 -CLEAN functions: 2020/08/31 16:34:48 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag* Delete Empty Channels: 0 deleted. -CALIB parameters: 2020/08/31 16:35:11 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = D:\Telework\2005-006\Processing\doc\2005-006-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 14 Oxygen:Dissolved:SBE mL/L 10 0.0000000E+00 0.1095000E+01 -SORT parameters: 2020/08/31 16:35:18 Sorted in ascending order of channel Pressure:StrainGauge [decibar] -REMOVECH 2020/08/31 16:35:57 The following CHANNEL(S) were removed: Scan_Number Oxygen:Voltage:SBE [volts] Descent_Rate [m/s] Flag -CHANGE units: Temperature reference channel: Temperature:Primary [deg C (ITS90)] Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE [mL/L]' changed from mL/L to umol/kg -HEADER EDITS: 2020/08/31 16:36:43 Applied edit header: D:\Telework\2005-006\Processing\doc\HYDRO\2005-006-bot-hdr.txt Channel 4: Pressure [decibar] Name: Pressure:StrainGauge ==> Pressure Format: F10.3 ==> F7.1 Channel 5: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 7: Conductivity:Primary [S/m] Format: F11.6 ==> F10.6 Channel 11: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 20: Nitrate_plus_Nitrite [umol/L] Format: F10.3 ==> F7.2 Channel 22: Silicate [umol/L] Format: F10.3 ==> F7.2 Channel 24: Phosphate [umol/L] Format: F10.3 ==> F7.2 -HEADER EDITS: 2021/09/07 10:16:02 Applied edit header: C:\Users\huntingtons\Desktop\2005-006-hdr-fix.txt $END *COMMENTS SBE HEADER Sea-Bird SBE 25 Data File: FileName = C:\2005-06\2005-06-043.hex Software Version Seasave Win32 V 5.33 Temperature SN = 034115 Conductivity SN = 042607 System UpLoad Time = Oct 07 2005 22:33:16 Ship: CCGS "Sir Wilfrid Laurier" Cruise: 2005-06 Station: BCH-04 Latitude: 71 06.274 N Longitude: 159 21.288 W depth(m): 84 Real-Time Sample Interval = 0.125 seconds # nquan = 14 # nvalues = 567 # units = specified # name 0 = scan: Scan Count # name 1 = bpos: Bottle Position in Carousel # name 2 = nbf: Bottles Fired # name 3 = prSM: Pressure, Strain Gauge [db] # name 4 = depSM: Depth [salt water, m] # name 5 = t090C: Temperature [ITS-90, deg C] # name 6 = c0S/m: Conductivity [S/m] # name 7 = xmiss: Beam Transmission, Chelsea/Seatech [%] # name 8 = flSP: Fluorescence, Seapoint # name 9 = sbeox0V: Oxygen raw, SBE 43 [V] # name 10 = dz/dtM: Descent Rate [m/s] # name 11 = sal00: Salinity, Practical [PSU] # name 12 = sbeox0ML/L: Oxygen, SBE 43 [ml/l] # name 13 = flag: 0.000e+00 # interval = seconds: 0.125 # start_time = Oct 07 2005 22:33:16 [System UpLoad Time] # bad_flag = -9.990e-29 # # # # # 034115 # 10-Dec-04 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.35844944e-003 # 6.45635712e-004 # 2.31397594e-005 # 2.06164012e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 042607 # 20-Jan-05 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -9.12563833e+000 # 1.27338380e+000 # -1.79199514e-003 # 1.84253585e-004 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 290464 # 27-Dec-2002 # 7.962542e+002 # -2.073565e-001 # 2.519294e-007 # 0.60000 # # # # # # 43-0615 # 09-Mar-2004 # 0 # # # 0.0000 # 3.9160e-001 # -0.4643 # 1.35e-004 # 0.0011 # 0.0 # # # # 0.0000e+000 # 0.0000 # 0.0000e+000 # 0.0000e+000 # 0.0000e+000 # 2.5826e+000 # 1.92634e-004 # -4.64803e-002 # 0.0000e+000 # 0.0000 #

-3.3000e-002

#

5.0000e+003

#

1.4500e+003

#
#
#
# # # # # # # # # # # # # 0.00000000 # 1.00000000 # 0.00000000 # 0.00000000 # # # # # # 2336 # # # 2 # 0.000 # # # # # # SeaTech # 23 APR 2001 # 20.8310 # -0.1250 # 0.250 # # #
# datcnv_date = Aug 19 2020 10:47:14, 7.23.2 # datcnv_in = D:\Telework\2005-006\RAW CTD Data\2005-006-0043.hex D:\Telework\20 05-006\Processing\doc\2005-006-ctd.xmlcon # datcnv_ox_hysteresis_correction = no # datcnv_ox_tau_correction = yes # datcnv_bottle_scan_range_source = BL file # datcnv_scans_per_bottle = 81 END* Comments from secondary file: D:\Telework\2005-006\Processing\hydro\2005-006-0043.mrg1 -------------------------------------------------------- Sample_Number 230: SIL: poor relicate CTD Data Processing Notes: -------------------------- Conductivity and Fluorescence:URU:Wetlabs data are nominal and unedited except that some records were removed in editing temperature and salinity. Channel Oxygen:Dissolved:SBE has been recalibrated based on a comparison with titrated samples. The data have not been edited. The response time of this type of sensor was long in 2005. The errors caused by this are partly addressed in the recalibration. The sensor performance was aided by the fact that local vertical gradients were frequently low. While the CTD fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples. No chlorophyll samples were available from this cruise at the time of processing. For details on the processing see document: 2005-006_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0 1.095) $END !-1-- 2- 3- --4--- --5--- ---6---- ----7---- --8-- ---9--- ---10--- --11-- --12- -13- ---14--- 15 ---16-- 17 --18-- 19 --20-- 21 --22-- 23 --24-- 25 !Samp Bo Bo Pressu Depth Temperat Conductiv Trans Fluores Salinity Oxygen Oxyge Numb Salinity Fl Oxygen: Fl Barium Fl Nitrat Fl Silica Fl Phosph Fl !le_ tt tt re ure: ity: missi cence: :T0:C0 : n: er_o :Bottle ag Dissolv ag : ag e_ ag te ag ate ag !Numb ~i ~u Primary Primary vity URU: Dissol Disso ~bin ~o ed ~o Dissol ~o plus_ ~t ~i ~p !er ti mb Seapoin ved: lved: _rec tt lv ved lv Nitrit ri ca ha ! on er t SBE SBE ords le ed ed e te te te !---- -- -- ------ ------ -------- --------- ----- ------- -------- ------ ----- ---- -------- -- ------- -- ------ -- ------ -- ------ -- ------ -- *END OF HEADER 230 7 7 4.5 4.5 2.6382 2.816934 14.4 1.011 31.1069 7.60 331.0 81 31.1115 0 7.588 6 66.6 0 0.80 0 9.70 3 0.94 0 229 6 6 24.2 23.9 2.4857 2.806262 14.6 1.014 31.1149 7.58 330.4 81 31.1164 0 7.602 6 76.0 0 0.70 0 10.00 0 0.97 0 228 5 5 29.8 29.5 2.8250 2.865290 36.1 1.263 31.4988 7.59 330.8 81 31.4987 0 7.637 6 54.7 0 0.10 0 4.20 0 0.71 0 227 4 4 40.9 40.4 2.1101 2.831203 36.4 0.664 31.7842 7.68 334.3 81 31.7384 0 7.696 6 62.8 0 0.20 0 5.80 0 0.86 0 226 3 3 49.1 48.6 -0.4901 2.679832 11.8 0.530 32.5296 7.45 323.9 81 32.5358 0 7.455 6 96.5 0 3.80 0 19.60 0 1.82 0 225 2 2 59.3 58.7 -0.5821 2.673939 11.7 0.558 32.5436 7.38 321.1 81 32.5546 0 7.394 6 105.9 0 4.40 0 19.90 0 1.86 0 224 1 1 72.5 71.7 -1.3641 2.624225 12.1 0.475 32.7107 7.17 311.7 81 32.7120 0 7.156 6 -99.0 0 8.40 0 26.90 0 2.08 0