*2021/09/07 10:14:15.15 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2005/09/23 20:59:11.000 TIME INCREMENT : 0 0 0 0.125 0 ! (day hr min sec ms) NUMBER OF RECORDS : 3 DATA DESCRIPTION : Bottle:Rosette + CTD:Up FILE TYPE : ASCII CRC : 586D16B9 NUMBER OF CHANNELS : 17 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 1 3 2 Bottle:Position n/a 1 12 3 Bottle_Number n/a 1 12 4 Pressure decibar 5.14 46.252 5 Depth metres 5.088 45.781 6 Temperature:Primary 'deg C (ITS90)' -0.994 0.9538 7 Conductivity:Primary S/m 2.345304 2.431068 8 Transmissivity %/metre 28.8 39.8 9 Fluorescence:URU:Seapoint mg/m^3 0.609 1.412 10 Salinity:T0:C0 PSS-78 26.8292 29.1299 11 Oxygen:Dissolved:SBE mL/L 6.467 9.093 12 Oxygen:Dissolved:SBE umol/kg 282.1048 397.4004 13 Number_of_bin_records n/a 20 81 14 Salinity:Bottle PSS-78 27.0713 29.0687 15 Flag:Salinity:Bottle ' ' 16 Oxygen:Dissolved mL/L 6.547 8.891 17 Flag:Oxygen:Dissolved ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 3 I I ' ' 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 7 F ' ' 1 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 10 F ' ' 6 8 -99 ' ' 6 F ' ' 1 9 -99 ' ' 8 F ' ' 3 10 -99 ' ' 9 F ' ' 4 11 -99 ' ' 7 F ' ' 2 12 -99 ' ' 6 F ' ' 1 13 ' ' ' ' 5 I I 0 14 -99 ' ' 9 F R4 4 15 0 ' ' 3 NQ C ' ' 16 -99 ' ' ' ' F8.3 R4 ' ' 17 0 ' ' 3 NQ C ' ' $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ---------------------------------------------------------------------------------- 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ---------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-006 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : JWACS-2005 SCIENTIST : van Hardenberg B. PLATFORM : Sir Wilfrid Laurier *LOCATION GEOGRAPHIC AREA : Beaufort Sea / Chukchi Sea STATION : CBAY EVENT NUMBER : 1 LATITUDE : 69 6.54000 N ! (deg min) LONGITUDE : 105 3.76000 W ! (deg min) WATER DEPTH : 52.5 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 0293 $TABLE: SENSORS ! Name Abs Depth Serial No ! --------------------------------- -------------- ---------- Temperature ' ' 034115 Conductivity ' ' 042607 'Pressure:Strain Gauge' ' ' 290464 'Oxygen:SBE 43' ' ' 43-0615 'User Polynomial' ' ' ' ' Fluorometer:Seapoint ' ' 2336 Transmissometer:Chelsea/Seatech ' ' SeaTech $END $REMARKS Software Version Seasave Win32 V 5.33 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 4.2.3 2020/08/19 14:11:42 472 472 CLEAN 5.2.4 2020/08/19 14:14:08 472 472 ADDSAMP 3.6 2020/08/20 11:33:47 472 472 BINAVE 4.2.1 2020/08/20 11:34:16 472 12 MERGE 3.5.1 2020/08/20 14:24:46 12 3 CLEAN 5.2.4 2020/08/31 16:34:48 3 3 CALIB 12.0.1 2020/08/31 16:35:08 3 3 SORT 3.6 2020/08/31 16:35:16 3 3 REMOVECH 8.2 2020/08/31 16:35:54 3 3 CHGUNITS 3.1.2 2020/08/31 16:36:06 3 3 REORDER 1.3.1 2020/08/31 16:36:15 ? ? HDREDIT2 3.2 2020/08/31 16:36:39 ? ? HDREDIT2 3.2 2021/09/07 10:14:15 ? ? $END $REMARKS -CLEAN functions: 2020/08/19 14:14:08 Reset #RECS, MIN & MAX values in header. Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: D:\Telework\2005-006\Processing\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2020/08/20 14:24:46 Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Barium:Dissolved, Flag:Barium:Dissolved, Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate Primary file : D:\Telework\2005-006\Processing\hydro\2005-006-0001.samavg Secondary file: D:\Telework\2005-006\Processing\hydro\2005-006-0001.mrg1 -CLEAN functions: 2020/08/31 16:34:48 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag* Delete Empty Channels: 8 deleted. -CALIB parameters: 2020/08/31 16:35:08 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = D:\Telework\2005-006\Processing\doc\2005-006-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 14 Oxygen:Dissolved:SBE mL/L 10 0.0000000E+00 0.1095000E+01 -SORT parameters: 2020/08/31 16:35:16 Sorted in ascending order of channel Pressure:StrainGauge [decibar] -REMOVECH 2020/08/31 16:35:54 The following CHANNEL(S) were removed: Scan_Number Oxygen:Voltage:SBE [volts] Descent_Rate [m/s] Flag -CHANGE units: Temperature reference channel: Temperature:Primary [deg C (ITS90)] Salinity reference channel: Salinity:T0:C0 [PSS-78] 'Oxygen:Dissolved:SBE [mL/L]' changed from mL/L to umol/kg -HEADER EDITS: 2020/08/31 16:36:39 Applied edit header: D:\Telework\2005-006\Processing\doc\HYDRO\2005-006-bot-hdr.txt Channel 4: Pressure [decibar] Name: Pressure:StrainGauge ==> Pressure Format: F10.3 ==> F7.1 Channel 5: Depth [metres] Name: Depth:Salt_Water ==> Depth Format: F10.3 ==> F7.1 Channel 7: Conductivity:Primary [S/m] Format: F11.6 ==> F10.6 Channel 11: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 -HEADER EDITS: 2021/09/07 10:14:15 Applied edit header: C:\Users\huntingtons\Desktop\2005-006-hdr-fix.txt $END *COMMENTS SBE HEADER Sea-Bird SBE 25 Data File: FileName = C:\2005-06\2005-06-001.hex Software Version Seasave Win32 V 5.33 Temperature SN = 034115 Conductivity SN = 042607 System UpLoad Time = Sep 23 2005 20:59:11 NMEA Latitude = 69 6.540 N NMEA Longitude = 105 3.760 W NMEA UTC (Time) = none Store Lat/Lon Data = Add to Header Only Ship: CCGS "Sir Wilfrid Laurier" Cruise: 2005-06 Station: CBAY depth(m): 52.5 m Real-Time Sample Interval = 0.125 seconds # nquan = 14 # nvalues = 472 # units = specified # name 0 = scan: Scan Count # name 1 = bpos: Bottle Position in Carousel # name 2 = nbf: Bottles Fired # name 3 = prSM: Pressure, Strain Gauge [db] # name 4 = depSM: Depth [salt water, m] # name 5 = t090C: Temperature [ITS-90, deg C] # name 6 = c0S/m: Conductivity [S/m] # name 7 = xmiss: Beam Transmission, Chelsea/Seatech [%] # name 8 = flSP: Fluorescence, Seapoint # name 9 = sbeox0V: Oxygen raw, SBE 43 [V] # name 10 = dz/dtM: Descent Rate [m/s] # name 11 = sal00: Salinity, Practical [PSU] # name 12 = sbeox0ML/L: Oxygen, SBE 43 [ml/l] # name 13 = flag: 0.000e+00 # interval = seconds: 0.125 # start_time = Sep 23 2005 20:59:11 [System UpLoad Time] # bad_flag = -9.990e-29 # # # # # 034115 # 10-Dec-04 # 1 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.000 # 4.35844944e-003 # 6.45635712e-004 # 2.31397594e-005 # 2.06164012e-006 # 1000.000 # 1.00000000 # 0.0000 # # # # # # 042607 # 20-Jan-05 # 1 # # 0.0000 # 2000.0000 # 0 # # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.00000000e+000 # 0.0 # -9.57000000e-008 # # # -9.12563833e+000 # 1.27338380e+000 # -1.79199514e-003 # 1.84253585e-004 # -9.57000000e-008 # 3.2500e-006 # # 0.00000000e+000 # # 1.00000000 # 0.00000 # # # # # # 290464 # 27-Dec-2002 # 7.962542e+002 # -2.073565e-001 # 2.519294e-007 # 0.60000 # # # # # # 43-0615 # 09-Mar-2004 # 0 # # # 0.0000 # 3.9160e-001 # -0.4643 # 1.35e-004 # 0.0011 # 0.0 # # # # 0.0000e+000 # 0.0000 # 0.0000e+000 # 0.0000e+000 # 0.0000e+000 # 2.5826e+000 # 1.92634e-004 # -4.64803e-002 # 0.0000e+000 # 0.0000 #

-3.3000e-002

#

5.0000e+003

#

1.4500e+003

#
#
#
# # # # # # # # # # # # # 0.00000000 # 1.00000000 # 0.00000000 # 0.00000000 # # # # # # 2336 # # # 2 # 0.000 # # # # # # SeaTech # 23 APR 2001 # 20.8310 # -0.1250 # 0.250 # # #
# datcnv_date = Aug 19 2020 10:45:47, 7.23.2 # datcnv_in = D:\Telework\2005-006\RAW CTD Data\2005-006-0001.hex D:\Telework\20 05-006\Processing\doc\2005-006-ctd.xmlcon # datcnv_ox_hysteresis_correction = no # datcnv_ox_tau_correction = yes # datcnv_bottle_scan_range_source = BL file # datcnv_scans_per_bottle = 81 END* Comments from secondary file: D:\Telework\2005-006\Processing\hydro\2005-006-0001.mrg1 -------------------------------------------------------- Sample_Number 2: ALL: Sample #11 changed to #2 because of duplication Sample_Number 3: ALL: Sample #12 changed to #3 because of duplication CTD Data Processing Notes: -------------------------- Conductivity and Fluorescence:URU:Wetlabs data are nominal and unedited except that some records were removed in editing temperature and salinity. Channel Oxygen:Dissolved:SBE has been recalibrated based on a comparison with titrated samples. The data have not been edited. The response time of this type of sensor was long in 2005. The errors caused by this are partly addressed in the recalibration. The sensor performance was aided by the fact that local vertical gradients were frequently low. While the CTD fluorescence data are expressed in concentration units, they do not always compare well to extracted chlorophyll samples. No chlorophyll samples were available from this cruise at the time of processing. For details on the processing see document: 2005-006_Processing_Report.doc. --------------------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0 1.095) $END !-1-- 2- 3- --4--- --5--- ---6---- ----7---- --8-- ---9--- ---10--- --11-- --12- -13- ---14--- 15 ---16-- 17 !Samp Bo Bo Pressu Depth Temperat Conductiv Trans Fluores Salinity Oxygen Oxyge Numb Salinity Fl Oxygen: Fl !le_ tt tt re ure: ity: missi cence: :T0:C0 : n: er_o :Bottle ag Dissolv ag !Numb ~i ~u Primary Primary vity URU: Dissol Disso ~bin ~o ed ~o !er ti mb Seapoin ved: lved: _rec tt lv ! on er t SBE SBE ords le ed !---- -- -- ------ ------ -------- --------- ----- ------- -------- ------ ----- ---- -------- -- ------- -- *END OF HEADER 3 12 12 5.1 5.1 0.9538 2.345304 28.8 0.663 26.8292 9.09 397.4 81 27.0713 2 8.891 6 2 11 11 20.6 20.4 0.1850 2.431068 29.2 1.412 28.6027 8.30 362.3 81 -99.0000 0 -99.000 0 1 1 1 46.3 45.8 -0.9940 2.386930 39.8 0.609 29.1299 6.47 282.1 20 29.0687 0 6.547 6