*2014/11/20 09:54:41.47 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2005/07/18 13:46:19.000 TIME INCREMENT : 0 0 0 0.125 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 10 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 92 92 2 Pressure decibar 29.488 29.488 3 Temperature:Primary 'deg C (ITS90)' 4.8062 4.8062 4 Salinity:T0:C0 PSS-78 31.3029 31.3029 5 Transmissivity %/metre 57.6 57.6 6 Fluorescence:URU:Seapoint mg/m^3 0.46E-01 0.46E-01 7 Bottle_Number n/a 1 1 8 Number_of_bin_records n/a 30 30 9 Salinity:Bottle PSS-78 31.2979 31.2979 10 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 3 I I 0 8 ' ' ' ' 5 I I 0 9 -99 ' ' 9 F R4 4 10 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-05 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : JWACS-2005 SCIENTIST : van Hardenberg B. PLATFORM : Sir Wilfrid Laurier *LOCATION GEOGRAPHIC AREA : Bering Strait/Bering Sea/Chukchi Sea STATION : UTN-1 EVENT NUMBER : 63 LATITUDE : 66 42.50100 N ! (deg min) LONGITUDE : 168 23.89500 W ! (deg min) WATER DEPTH : 34 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 0293 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature ' ' 034115 conductivity ' ' 042607 Pressure ' ' 290464 Oxygen:SBE ' ' 43-0615 userpoly ' ' ' ' Fluorometer ' ' Seapoint transmissometer:primary ' ' SeaTech $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.33 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.9 2005/12/09 13:24:58 275 275 CLEAN 4.8.1 2005/12/09 13:25:48 ? ? ADDSAMP 3.4 2005/12/09 17:12:20 275 275 BINAVE 4.1 2005/12/13 12:36:56 275 7 MERGE 3.3 2005/12/13 12:37:08 7 1 CLEAN 4.8.1 2006/01/26 09:32:34 ? ? SORT 3.5 2006/01/26 09:33:06 1 1 REMOVECH 7.0 2006/01/26 10:39:56 1 1 HDREDIT2 2.5.1 2006/01/26 10:42:54 ? ? HDREDIT2 2.5.1 2006/12/12 18:01:14 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:29:59 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:31:59 1 1 REMOVECH 8.2 2013/12/16 17:31:34 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:54:41 1 1 $END $REMARKS -CLEAN functions: 2005/12/09 13:25:39 20 Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2005-05\CTD\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 0.50 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Standard Deviation channels were added Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2005/12/13 12:37:04 2005/12/13 12:37:04 2005/12/13 12:37: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2005-05\CTD\hydro\2005-05-0063.samavg Secondary file: Q:\Cruise_Data\2005-05\CTD\hydro\2005-05-0063.sal -CLEAN functions: 2006/01/26 09:32:32 20 Remove Sea-Bird comments from the header. -SORT parameters: 2006/01/26 09:33:06 Sorted in ascending order of channel Pressure:StrainGauge -REMOVECH 2006/01/26 10:39:56 The following CHANNEL(S) were removed: Scan_Number Scan_Number:STD Conductivity:Primary [S/m] Conductivity:Primary:STD [S/m] Oxygen:Voltage:SBE [volts] Oxygen:Voltage:SBE:STD [volts] Oxygen:Dissolved:SBE [mL/L] Oxygen:Dissolved:SBE:STD [mL/L] Descent_Rate [m/s] Descent_Rate:STD [m/s] Bottle_Number:STD Flag Flag:STD Sample_Number:STD -HEADER EDITS: 2006/01/26 10:42:54 Applied edit header: Q:\Cruise_Data\2005-05\CTD\doc\2005-05-SBE25-hdr.txt Channel 2: Pressure [decibar] Name: Pressure:StrainGauge ==> Pressure Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 3: Pressure:STD [dbars] Name: Pressure:StrainGauge:STD ==> Pressure:STD Channel 10: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 11: Fluorescence:URU:Seapoint:STD [mg/m^3] Name: Fluorescence:Seapoint:STD ==> Fluorescence:URU:Seapoint:STD -HEADER EDITS: 2006/12/12 18:01:14 Applied edit header: Q:\Cruise_Data\Bottle Header Fix\fix-hdr-qual.txt -REMOVECH 2013/12/16 17:31:34 The following CHANNEL(S) were removed: Pressure:STD [decibar] Temperature:Primary:STD [deg C (ITS90)] Salinity:T0:C0:STD [PSS-78] Transmissivity:STD [%/metre] Fluorescence:URU:Seapoint:STD [mg/m^3] $END *COMMENTS --------------------------------------------------------------------- Fluorescence:URU:Seapoint – The data are uncalibrated and unedited. Transmissivity: The data are nominal and unedited. The pressure sensor is considered ±1db. The salinity is considered ±0.005psu except in areas of rapid temperature change where the salinity has been edited heavily and should be considered ±0.1psu. The dissolved oxygen data was removed because there was no calibration sampling. !-1-- --2--- ---3---- ---4---- --5-- ---6--- 7- -8-- ---9---- - !Samp Pressu Temperat Salinity Trans Fluores Bo Numb Salinity F !le_ re ure: :T0:C0 missi cence: tt er_o :Bottle l !Numb Primary vity URU: ~u ~bin ~ !er Seapoin mb _rec l ! t er ords e !---- ------ -------- -------- ----- ------- -- ---- -------- - *END OF HEADER 92 29.5 4.8062 31.3029 57.6 0.046 1 30 31.2979 0