*2014/11/20 09:54:38.08 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2005/02/22 02:33:09.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 11 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 391 391 2 Pressure decibar 4.5 4.5 3 Temperature:Secondary 'deg C (ITS90)' 8.4844 8.4844 4 Transmissivity %/metre 40.3 40.3 5 Fluorescence:URU:Seapoint mg/m^3 1.028 1.028 6 Oxygen:Dissolved:SBE mL/L 6.67 6.67 7 Salinity:T1:C1 PSS-78 32.5051 32.5051 8 Bottle_Number n/a 1 1 9 Number_of_bin_records n/a 121 121 10 Salinity:Bottle PSS-78 32.5107 32.5107 11 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 3 I I 0 9 ' ' ' ' 5 I I 0 10 -99 ' ' 9 F R4 4 11 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2005-01 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : North East Pacific STATION : P1E 100 EVENT NUMBER : 75 LATITUDE : 47 0.05000 N ! (deg min) LONGITUDE : 136 50.98000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2399 pressure ' ' 63507 temperature:secondary ' ' 2106 conductivity:secondary ' ' 1763 Fluorometer ' ' Seapoint transmissometer:primary ' ' 333DR Oxygen:SBE ' ' 0766 irradiance:primary ' ' 4656 altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.32 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.9 2005/03/31 16:11:56 121 121 CLEAN 4.7.1 2005/03/31 16:13:00 121 121 ADDSAMP 3.4 2005/04/01 12:01:30 121 121 BINAVE 4.1 2005/04/01 12:02:17 121 1 MERGE 3.3 2005/05/26 09:06:47 1 1 MERGE 3.3 2005/05/26 09:06:59 1 1 MERGE 3.3 2005/05/26 09:07:12 1 1 CALIB 11.4 2005/05/26 12:08:38 1 1 MERGE 3.3 2005/06/06 16:48:09 1 1 CLEAN 4.8 2005/06/06 16:49:06 ? ? SORT 3.5 2005/06/06 16:49:27 1 1 REMOVECH 7.0 2005/06/06 16:49:59 1 1 HDREDIT2 2.5 2005/06/06 16:52:18 ? ? CLEAN 5.0 2006/06/06 14:35:58 1 1 CHANGE_FLAGS 1.0 2013/07/29 14:29:56 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:31:55 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:54:38 1 1 $END $REMARKS -CLEAN functions: 2005/03/31 16:12:12 20 Interpolation by Channel 1: Scan_Number [n/a] in Pressure Change Pad Value to -99 in Channel: Oxygen:Dissolved:SBE [mL/L] Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2005-01\CTD files\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: 2005/05/26 09:06:44 2005/05/26 09:06:44 2005/05/26 09:06: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.samavg Secondary file: Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.mrg1 Secondary file: Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.add -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.mrg2 Secondary file: Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-0075.nut1 -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2005-01\CTD files\hydro\2005-01-recal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 12 Oxygen:Dissolved:SBE mL/L 10 0.1032000E+00 0.1484000E+01 15 Salinity:T1:C1 PSS-78 10 0.4400000E-02 0.1000000E+01 -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2005-01\CTD files\test\2005-01-0075.mrgcor1 Secondary file: Q:\Cruise_Data\2005-01\CTD files\test\2005-01-0075.chl1 -CLEAN functions: 2005/06/06 16:49:04 20 Remove Sea-Bird comments from the header. -SORT parameters: 2005/06/06 16:49:27 Sorted in ascending order of channel Pressure -REMOVECH 2005/06/06 16:49:59 The following CHANNEL(S) were removed: Scan_Number Temperature:Primary [deg C (ITS90)] Conductivity:Primary [S/m] Conductivity:Secondary [S/m] Altimeter [metres] Oxygen:Voltage:SBE [volts] PAR [uE/m^2/sec] Salinity:T0:C0 [PSS-78] Flag -HEADER EDITS: 2005/06/06 16:52:18 Applied edit header: Q:\Cruise_Data\2005-01\CTD files\doc\2005-01-bot-hdr.txt Channel 2: Pressure [decibar] Units: dbars ==> decibar Format: F10.3 ==> F7.1 Channel 5: Fluorescence:URU:Seapoint [mg/m^3] Name: Fluorescence:Seapoint ==> Fluorescence:URU:Seapoint Channel 6: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 -CLEAN functions: 2006/06/06 14:34:01 20 Reset #RECS, MIN & MAX values in header. $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. chl a filtered on board (Jeri Butcher), not analysed on board Chlorophyll analyzed by S. Toews at IOS using calibration factors Feb.2005 References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. ************************************************************************** There were problems with the calibration of the SBE salinity. The salinometer malfunctioned and data run before and after repair look notably different. The later data has been used for recalibration, but there remain some doubts about it. The SBE dissolved oxygen sensor data were recalibrated differently for the earlier casts. Anoxic conditions during cast #1 may have affected the sensor up to cast #15. All casts from #15 onward were treated the same. The DO comparison with bottles had more scatter than usual. ************************************************************************** *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.1032 1.484) Salinity:T1:C1 PSS-78 10 -99 () (0.44E-02 1) $END !-1-- --2--- ---3---- --4-- ---5--- --6--- ---7---- 8- -9-- ---10--- - !Samp Pressu Temperat Trans Fluores Oxygen Salinity Bo Numb Salinity F !le_ re ure: missi cence: : :T1:C1 tt er_o :Bottle l !Numb Secondar vity URU: Dissol ~u ~bin ~ !er y Seapoin ved: mb _rec l ! t SBE er ords e !---- ------ -------- ----- ------- ------ -------- -- ---- -------- - *END OF HEADER 391 4.5 8.4844 40.3 1.028 6.67 32.5051 1 121 32.5107 0