*2017/03/10 09:46:31.17 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2004/08/25 22:41:00.000 NUMBER OF RECORDS : 24 DATA DESCRIPTION : 'Bottle:Rosette:Up:NoStop and Stop as specified in' CONTINUED : ' SAMPLE METHOD' FILE TYPE : ASCII NUMBER OF CHANNELS : 23 CTD : Up except for oxygen which is from the down-cast. $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 690 713 2 Sample_Method ' ' 3 Bottle_Number n/a 1 24 4 Pressure decibar 7.3 3143.5 5 Temperature 'deg C (ITS90)' -1.5278 0.4539 6 Salinity PSS-78 26.3432 34.9569 7 Oxygen:Dissolved:SBE mL/L 6.19 9.09 8 Fluorescence:Calibrated:Seapoint mg/m^3 0.34E-01 0.379 9 Transmissivity %/metre 62 65.3 10 Salinity:Bottle PSS-78 26.366 34.9577 11 Flag:Salinity:Bottle ' ' 12 Oxygen:Dissolved mL/L 6.091 9.103 13 Flag:Oxygen:Dissolved ' ' 14 Nitrate_plus_Nitrite umol/L 0 16.5 15 Flag:Nitrate_plus_Nitrite ' ' 16 Silicate umol/L 2.9 35.3 17 Flag:Silicate ' ' 18 Phosphate umol/L 0.56 1.9 19 Flag:Phosphate ' ' 20 Oxygen:Isotope:18 /mille 0.17 0.17 21 Flag:Oxygen:Isotope:18 ' ' 22 Barium:Dissolved nmol/L 49.9 49.9 23 Flag:Barium:Dissolved ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 ' ' ' ' 8 NQ C ' ' 3 -99 ' ' 3 I I 0 4 -99 ' ' ' ' F7.1 R4 ' ' 5 -99 ' ' ' ' F9.4 R4 ' ' 6 -99 ' ' ' ' F9.4 R4 ' ' 7 -99 ' ' ' ' F7.2 R4 ' ' 8 -99 ' ' 8 F R4 3 9 -99 ' ' 6 F R4 1 10 -99 ' ' ' ' F9.4 R4 ' ' 11 ' ' ' ' 3 NQ C ' ' 12 -99 ' ' ' ' F8.3 R4 ' ' 13 ' ' ' ' 3 NQ C ' ' 14 -99 ' ' ' ' F7.2 R4 ' ' 15 ' ' ' ' 3 NQ C ' ' 16 -99 ' ' ' ' F7.2 R4 ' ' 17 ' ' ' ' 3 NQ C ' ' 18 -99 ' ' ' ' F8.3 R4 ' ' 19 ' ' ' ' 3 NQ C ' ' 20 -99 ' ' ' ' F7.2 R4 ' ' 21 ' ' ' ' 3 NQ C ' ' 22 -99 ' ' ' ' F7.1 R4 ' ' 23 ' ' ' ' 3 NQ C ' ' $END $REMARKS Flag channels were initialized with zeros. Non-zero values have the following significance: ------------------------------------------------------------------------------------------- 1 = Sample for this measurement was collected but not analyzed. Sample lost. 2 = Acceptable Measurement 3 = Questionable Measurement (Probably Good) 4 = Poor Measurement (Probably Bad) 5 = Measurement Not Reported (Bad) 6 = Mean of replicate measurements 7 = Manual chromatographic peak measurement 8 = Irregular digital chromatographic peak integration 9 = Sample was planned for this measurement from this bottle but was not collected ------------------------------------------------------------------------------------------- Sampling Methods are expressed with the following codes: ------------------------------------------------------------------------------- ROS:UN - No Stop ROS:US - Stop for 30 seconds ROS:USM - Up Stop Mix (Stop 30s, up 1m, down 2m, up 1m, wait 30s, close bottle) ------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2004-16 AGENCY : IOS, Ocean Sciences Division, Sidney, B.C. COUNTRY : Canada PROJECT : Joint Ocean Ice Study (JOIS incl JWACS and BGOS) SCIENTIST : McLaughlin F. PLATFORM : Louis S. St. Laurent *LOCATION GEOGRAPHIC AREA : Arctic Ocean's Canada Basin STATION : CB-22(2) EVENT NUMBER : 40 LATITUDE : 73 23.49000 N ! (deg min) LONGITUDE : 137 10.15200 W ! (deg min) WATER DEPTH : 3092 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0724 $REMARKS A rosette, holding 24 ten-litre Niskin Bottles, with a CTD was used. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SPRD2IS 5.0 2015/03/17 15:50:15 24 24 CLEAN 5.2.1 2015/03/17 15:57:38 24 24 HDREDIT2 3.0.2 2015/03/18 16:39:10 ? ? CALIB 11.8.1 2015/03/18 16:40:46 24 24 HDREDIT2 3.0.2 2015/03/20 16:37:16 ? ? CLEAN 5.2.2 2017/03/03 15:40:40 24 24 HDREDIT2 3.1.1 2017/03/03 15:44:25 ? ? HDREDIT2 3.1.1 2017/03/10 09:30:14 ? ? SORT 3.6 2017/03/10 09:46:31 24 24 $END $REMARKS -CLEAN functions: 2015/03/17 15:57:36 20 Reset #RECS, MIN & MAX values in header. Change character data from " " to "0" in channels Flag:* -HEADER EDITS: 2015/03/18 16:39:10 Applied edit header: C:\Users\zimmermanns\Documents\GArchiveProcess\Chem\3_header\2004-16- HDRChemv2.TXT -CALIB parameters: 2015/03/18 16:40:46 Calibration type = Calculate Mode: HEAD - calibration specs from header only. Transmissivity converted to %/metre WARNING: No calibration done on file C:\Users\zimmermanns\Documents\GArchiveProcess\Chem\4_ TransUnits\2004-16-0040.trn -HEADER EDITS: 2015/03/20 16:37:16 Channel 2: Sample_Method [] Units: n/a ==> Channel 3: Bottle_Number [n/a] Format: I5 ==> I3 Channel 9: Transmissivity [%/metre] Format: F7.2 ==> F6.1 -CLEAN functions: 2017/03/03 15:40:38 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 5 deleted. -HEADER EDITS: 2017/03/03 15:44:25 Applied edit header: Z:\SHARE\DATA\Data Archive Process - 2017\Joe's work\2004-16\Headers\2004-16 CHE Header.txt Channel 8: Fluorescence:Calibrated:Seapoint [mg/m^3] Name: Fluorescence:URU:Seapoint ==> Fluorescence:Calibrated:Seapoint -HEADER EDITS: 2017/03/10 09:30:14 Applied edit header: Z:\SHARE\DATA\Data Archive Process - 2017\Joe's work\Headers\Niskin Bottles. txt -SORT parameters: 2017/03/10 09:46:31 Sorted in ascending order of channel Pressure [decibar] $END *COMMENTS CTD Data Processing Notes: -------------------------- For full details see report "Physical and Chemical Data from the Canada Basin, August 2004" cited below. Altimeter added on Cast 15. Oxygen to match with bottle data is taken from the downcast, matching on density for the upper 600db and matching on pressure for depths greater than 600db. Temperature was calibrated with the pre-cruise calibrations. Conductivity, Oxygen and Fluorescence were calibrated to water samples. Salinity was recalculated using the corrected conductivity. Transmissometer and Altimeter are not calibrated. Fluorometer notes: Calibration with bottle data performed using bottle chlorophyll values between 0.025 and 0.6 mg/m3. The number of observations used were 75 out of 93 with a standard deviation of 0.02 in the residuals. Coefficients used: Slope: 1.4585, Bias -0.0026. Downcast CTD Fluorometer with bad values replaced with good upcast values for casts 19, 20 30, 34, 37 and 40. Remaining bad data replaced with -99. Oxygen Calibration: Casts 1 to 50 (full cruise) oxygen was calculated from oxygen voltage using the Seabird Owens-Millard algorithm using coefficients: boc: 0, tau: 0, tcor: 0.0015, pcor: 1.3500e-004, voffset: -0.4716, soc: 0.3753. A lag of -6 seconds was applied to oxygen voltage in Seabird data processing step Align. Chemistry Sampling and Analysis Methods: --------------------------------------- For full details see report "Physical and Chemical Data from the Canada Basin, August 2004" cited below. Salinity samples were collected in 200 mL type II glass bottles with disposable plastic inserts and screw caps. Onboard, samples were analyzed in a temperature-controlled lab on a Guildline AutoSalinometer Model 8400A (SN: 49463), which was standardized with IAPSO standard seawater. Onshore, samples were analyzed on the Guildline PortaSalinometer #59724, which was standardized with IAPSO standard seawater. Oxygen samples were collected in glass flasks and analyzed on board on an automated Winkler titration system following the procedures of Carpenter (1965). The titration was performed with a Metrohn Dosimat 665 and end point was detected using a Brinkmann probe Colorimeter PC910. Software written at the Institute of Ocean Sciences, NewAutoOxy.exe, was used to calculate dissolved oxygen (ml/L). Nutrient samples (nitrate plus nitrite, silicate and orthophosphate) were collected in glass and polystyrene test tubes. Samples collected in the Canada Basin were analyzed fresh on board, using a Technicon AAII auto-analyzer following methods described in Barwell-Clarke and Whitney (1996). Samples collected from 15 stations in the Canadian Archipelago were frozen and analyzed on shore using the same method. Total Chlorophyll-a (>0.7um) samples were collected into insulated plastic coolers and analyzed on board. 500 ml samples were filtered onto 25mm GF/F filters using low vacuum filtration. The filters were put into scintillation vials with 10 ml of 90% acetone, labeled and put into a 4 degree C cooler for 24 hours, then brought to room temperature for an hour and chlorophyll-a and phaeo-pigment levels were measured with a Turner Designs fluorometer (model 10-AU-005). The sample was acidified with 1.5N hydrochloric acid to obtain the phaeo-pigment reading. Oxygen Isotopes Samples were collected into 30 ml (approximate) glass vials. Once at room temperature, the caps were retightened and wrapped with electrical tape for storage. Samples were analyzed in May 2005 at Oregon State University using the H2O-CO2 equilibration method on a Finnigan MAT mass spectrometer. Barium samples were collected in ~20 ml plastic vials. Once at room temperature the caps were retightened for storage. Barium was determined at Oregon State University, using isotope-dilution and a VG Thermo Excel Inductively coupled quadrupole mass spectrometer as previously described with minor modifications (Falkner et al., 1994). Phytoplankton and bacterioplankton were collected in 2 ml capacity cryogenic vial and immediately fixed with 0.2 ml of 10% paraformaldehyde by vortex mixing. Samples were maintained for at least 15 min at laboratory temperature to allow fixation, and then stored at -80 degree C until analysis at the Bedford Institute of Oceanography. Cell concentrations of picophytoplankton, nanophytoplankton, and bacterioplankton (i.e. non-autofluorescent picoplankton) in thawed samples were analyzed by flow cytometry (Becton Dickinson FACSort) following protocols in routine use (Li and Dickie, 2001). References: 1. McLaughlin, F., Carmack, E.C., Zimmermann. S., Sieberg, D., White, L., Barwell Clarke, J., Steel, M., and Li, W.K.W. 2008. Physical and Chemical Data from the Canada Basin, August 2004. Can. Data Rep. Hydrogr. Ocean. Sci. 140: vi + 185 p. 2. Owens, W. B., and R. C. Millard Jr., 1985, A new algorithm for CTD oxygen calibration. J. Physical Oceanography., 15, 621-631. 3. Carpenter, J.H., 1965. The Chesapeake Bay Institute technique for the Winkler dissolved oxygen method, Limnol. Oceanogr., 10, 141-3. 4. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 5. Falkner, K.K., MacDonald, R.W., Carmack, E.C., and Weingartner, T. 1994. The potential of barium as a tracer of Arctic water masses, p. 63-76. In: O.M. Johannessen, R.D. Muench and J.E. Overland [eds.]. The Polar Oceans and Their Role in Shaping the Global Environment: The Nansen Centennial Volume, AGU Geophys. Monograph Series, AGU Books, Washington, DC. 6. Li, W.K.W., and Dickie, P.M. 2001. Monitoring phytoplankton, bacterioplankton, and virioplankton in a coastal inlet (Bedford Basin) by flow cytometry. Cytometry 44: 236-246. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! --------------------------- -------- ---- ------ ------------ Conductivity mS/cm 10 -99 () (-0.7E-03 1) Fluorescence:URU:Seapoint mg/m^3 10 -99 () (-0.26E-02 1.4585) $END !-1-- ---2--- 3- --4--- ---5---- ---6---- --7--- ---8--- --9-- ---10--- 11 ---12-- 13 --14-- 15 --16-- 17 ---18-- 19 --20-- 21 --22-- 23 !Samp Sample_ Bo Pressu Temperat Salinity Oxygen Fluores Trans Salinity Fl Oxygen: Fl Nitrat Fl Silica Fl Phospha Fl Oxygen Fl Barium Fl !le_ Method tt re ure : cence: missi :Bottle ag Dissolv ag e_ ag te ag te ag : ag : ag !Numb ~u Dissol Calibra vity ~o ed ~o plus_ ~t ~i ~p Isotop ~p Dissol ~o !er mb ved: ted:Sea tt lv Nitrit ri ca ha e:18 e: ved lv ! er SBE point le ed e te te te 18 ed !---- ------- -- ------ -------- -------- ------ ------- ----- -------- -- ------- -- ------ -- ------ -- ------- -- ------ -- ------ -- *END OF HEADER 713 ROS:UN 24 7.3 -1.1205 26.3432 8.78 0.048 63.5 26.3660 0 8.780 0 0.00 0 2.90 0 0.560 0 -99.00 0 -99.0 0 712 ROS:UN 23 27.4 -1.0015 28.8126 9.09 0.059 63.6 28.7993 0 9.103 0 0.00 0 3.10 0 0.620 0 -99.00 0 -99.0 0 711 ROS:UN 22 64.5 -0.3152 31.6577 8.32 0.379 62.0 31.6202 0 8.378 0 2.80 0 9.50 0 1.020 0 -99.00 0 -99.0 0 710 ROS:UN 21 70.4 -0.6840 31.8228 8.05 0.260 63.1 31.8029 0 8.112 0 5.10 0 12.20 0 1.190 0 -99.00 0 -99.0 0 709 ROS:UN 20 94.8 -1.2581 32.3275 7.15 0.059 64.5 32.3091 0 7.175 0 11.00 0 22.20 0 1.580 0 -99.00 0 -99.0 0 708 ROS:UN 19 118.2 -1.4075 32.6208 6.75 0.045 64.7 32.6132 0 6.718 0 13.80 0 30.00 0 1.770 0 -99.00 0 -99.0 0 707 ROS:UN 18 136.8 -1.4872 32.7788 6.66 0.042 64.7 32.7692 0 6.588 0 14.90 0 32.30 0 1.860 0 -99.00 0 -99.0 0 706 ROS:UN 17 169.3 -1.5278 33.1220 6.52 0.041 64.7 33.1050 0 6.494 0 16.20 0 35.20 0 1.900 0 -99.00 0 -99.0 0 705 ROS:UN 16 191.1 -1.4218 33.4257 6.33 0.041 64.8 33.4105 0 6.265 0 16.50 0 35.30 0 1.840 0 -99.00 0 -99.0 0 704 ROS:UN 15 207.4 -1.3176 33.7740 6.24 0.041 64.8 33.7467 0 6.167 0 14.70 0 28.70 0 1.550 0 -99.00 0 -99.0 0 703 ROS:UN 14 227.0 -0.9423 34.1164 6.19 0.040 64.9 34.0967 0 6.091 0 13.90 0 20.70 0 1.240 0 -99.00 0 -99.0 0 702 ROS:UN 13 260.3 -0.4711 34.4184 6.54 0.038 65.0 34.4061 0 6.544 0 12.20 0 11.20 0 0.920 0 -99.00 0 -99.0 0 701 ROS:UN 12 299.1 -0.0178 34.6137 6.56 0.036 65.0 34.6039 0 6.563 0 12.50 0 9.60 0 0.890 0 -99.00 0 -99.0 0 700 ROS:UN 11 406.2 0.4539 34.8083 6.76 0.034 65.1 34.8102 0 6.763 0 13.00 0 7.10 0 0.850 0 -99.00 0 -99.0 0 699 ROS:UN 10 503.7 0.4453 34.8377 6.80 0.034 65.2 34.8400 0 6.775 0 13.20 0 7.20 0 0.870 0 -99.00 0 -99.0 0 698 ROS:UN 9 603.5 0.4074 34.8585 6.78 0.035 65.2 34.8597 0 6.788 0 13.30 0 7.30 0 0.880 0 -99.00 0 -99.0 0 697 ROS:UN 8 803.6 0.1814 34.8757 6.87 0.036 65.2 34.8775 0 6.892 0 13.20 0 7.60 0 0.890 0 -99.00 0 -99.0 0 696 ROS:UN 7 1004.0 -0.0218 34.8902 6.89 0.038 65.2 34.8919 0 6.918 0 13.10 0 7.50 0 0.900 0 -99.00 0 -99.0 0 695 ROS:UN 6 1504.8 -0.3233 34.9201 6.87 0.041 65.3 34.9211 0 6.911 0 13.80 0 9.00 0 0.940 0 -99.00 0 -99.0 0 694 ROS:UN 5 1754.6 -0.3971 34.9333 6.80 0.042 65.3 34.9348 0 6.814 0 14.20 0 10.10 0 0.990 0 -99.00 0 -99.0 0 693 ROS:UN 4 2004.6 -0.4139 34.9437 6.71 0.043 65.3 34.9450 0 6.741 0 14.60 0 11.50 0 1.020 0 -99.00 0 -99.0 0 692 ROS:UN 3 2503.8 -0.3823 34.9542 6.58 0.046 65.3 34.9557 0 6.618 0 15.10 3 13.00 0 1.040 0 -99.00 0 49.9 0 691 ROS:UN 2 3004.8 -0.3325 34.9568 6.52 0.048 65.2 34.9577 0 6.559 0 15.20 3 13.80 0 1.050 0 0.17 0 -99.0 0 690 ROS:UN 1 3143.5 -0.3201 34.9569 6.53 0.049 65.2 34.9562 0 6.552 0 15.00 0 13.80 0 1.050 0 -99.00 0 -99.0 0