*2014/11/20 09:54:19.41 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2004/06/16 20:36:13.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 12 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 558 558 2 Pressure decibar 6 6 3 Temperature:Primary 'deg C (ITS90)' 9.8189 9.8189 4 Transmissivity %/metre 7.2 7.2 5 Oxygen:Dissolved:SBE mL/L 8.1405 8.1405 6 PAR uE/m^2/sec 83.7 83.7 7 Fluorescence:URU:Seapoint mg/m^3 14.639 14.639 8 Bottle_Number n/a 1 1 9 Salinity:T0:C0 PSS-78 29.0046 29.0046 10 Number_of_bin_records n/a 114 114 11 Salinity:Bottle PSS-78 28.6038 28.6038 12 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 7 F ' ' 2 6 -99 ' ' 7 F ' ' 1 7 -99 ' ' 8 F ' ' 3 8 -99 ' ' 3 I I 0 9 -99 ' ' 9 F ' ' 4 10 ' ' ' ' 5 I I 0 11 -99 ' ' 9 F R4 4 12 ' ' ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2004-10 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : N.E. Pacific STATION : RI3 EVENT NUMBER : 107 LATITUDE : 51 35.77000 N ! (deg min) LONGITUDE : 127 32.16000 W ! (deg min) WATER DEPTH : 330 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2023 conductivity:primary ' ' 1763 pressure ' ' 77511 temperature:secondary ' ' 2095 conductivity:secondary ' ' 1764 Fluorometer ' ' Seapoint Oxygen:SBE ' ' 0047 transmissometer:primary ' ' 498DR irradiance ' ' primary altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.30A $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/08/02 13:51:45 121 121 CLEAN 4.7 2004/08/02 13:53:28 ? ? ADDSAMP 3.4 2004/08/04 17:33:08 121 121 BINAVE 4.0.1 2004/08/04 17:34:45 121 1 MERGE 3.1 2004/08/05 08:47:55 1 1 MERGE 3.1 2004/08/05 08:56:22 1 1 CALIB 11.4 2004/08/13 14:37:17 1 1 CLEAN 4.7 2004/08/17 12:47:10 ? ? SORT 3.4.1 2004/08/17 12:49:28 1 1 REMOVECH 6.0 2004/08/17 12:53:55 1 1 HDREDIT2 2.2 2004/08/17 13:01:54 ? ? CALIB 11.4 2004/09/29 14:45:50 1 1 HDREDIT2 2.3 2004/12/07 14:39:45 ? ? CALIB 11.6 2005/10/12 13:52:25 1 1 CHANGE_FLAGS 1.0 2013/07/29 14:29:41 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:30:16 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:54:19 1 1 $END $REMARKS -CLEAN functions: Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2004-10\CTD files\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0107.samavg Secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0107.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0107.mrg1 Secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0107.add -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2004-10\CTD files\doc\2004-10-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Oxygen:Dissolved:SBE mL/L 10 0.3310000E-01 0.1077200E+01 17 Salinity:T0:C0 PSS-78 10 0.1000000E-02 0.1000000E+01 -CLEAN functions: Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Oxygen:Voltage:SBE Status:Pump Altimeter Descent_Rate Salinity:T1:C1 Flag -HEADER EDITS: Applied edit header: O:\Data Processing\Header Comments\sal_oxy_chl_fresh_nut_a Channel 1: Sample_Number [n/a] Pad: -9 ==> -99 Channel 2: Pressure [decibar] Units ==> dbars Format: F10.3 ==> F7.1 Channel 3: Temperature:Primary [deg C (ITS90)] (no changes) Channel 4: Transmissivity [%/metre] (no changes) Channel 5: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 6: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 7: Fluorescence:URU:Seapoint [mg/m^3] (no changes) Channel 8: Bottle_Number [n/a] (no changes) Channel 9: Salinity:T0:C0 [PSS-78] (no changes) Channel 10: Number_of_bin_records [n/a] Format: F5.0 ==> I5 Channel 11: Salinity:Bottle [] Units ==> PSS-78 Channel 12: Flag:Salinity:Bottle [] Units ==> n/a Pad: 0 ==> blank -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2004-10\DOC new\2004-10-recal3.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Salinity:T0:C0 PSS-78 10 0.5000000E-03 0.1000000E+01 -HEADER EDITS: 2004/12/07 14:39:45 Applied edit header: H:\STNPCHEM\Work\HEADERS\Geographic Area.txt -CALIB parameters: 2005/10/12 13:52:25 Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = C:\DATA\repair shop\2004-10\2004-10-recal3.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Oxygen:Dissolved:SBE mL/L 10 0.0000000E+00 0.1005000E+01 $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.331E-01 1.0772) Salinity:T0:C0 PSS-78 10 -99 () (0.1E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.5E-03 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0 1.005) $END !-1-- --2--- ---3---- --4-- --5--- --6--- ---7--- 8- ---9---- -10- ---11--- - !Samp Pressu Temperat Trans Oxygen PAR Fluores Bo Salinity Numb Salinity F !le_ re ure: missi : cence: tt :T0:C0 er_o :Bottle l !Numb Primary vity Dissol URU: ~u ~bin ~ !er ved: Seapoin mb _rec l ! SBE t er ords e !---- ------ -------- ----- ------ ------ ------- -- -------- ---- -------- - *END OF HEADER 558 6.0 9.8189 7.2 8.14 83.7 14.639 1 29.0046 114 28.6038 0