*2024/04/15 14:55:01.66 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 2004/06/02 09:39:33.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 21 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 2 9 2 Pressure decibar 5.9 112.9 3 Temperature:Primary 'deg C (ITS90)' 7.1134 13.7712 4 Transmissivity %/metre 49.3 58.6 5 Oxygen:Dissolved:SBE mL/L 2.29 6.49 6 Fluorescence:URU:Seapoint mg/m^3 0.136 1.949 7 Bottle_Number n/a 1 8 8 Salinity:T0:C0 PSS-78 31.4542 33.7835 9 Number_of_bin_records n/a 121 121 10 Salinity:Bottle PSS-78 31.4563 33.7862 11 Flag:Salinity:Bottle n/a 12 Nitrate_plus_Nitrite umol/L 0 32 13 Flag:Nitrate_plus_Nitrite n/a 14 Silicate umol/L 0.6 47.4 15 Flag:Silicate n/a 16 Phosphate umol/L 0.27 2.42 17 Flag:Phosphate n/a 18 Chlorophyll:Extracted mg/m^3 0.2E-01 1.34 19 Flag:Chlorophyll:Extracted n/a 20 Oxygen:Dissolved mL/L 2.227 6.419 21 Flag:Oxygen:Dissolved n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 7 F ' ' 2 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 3 I I 0 8 -99 ' ' 9 F ' ' 4 9 -99 ' ' 5 I I 0 10 -99 ' ' 9 F R4 4 11 -99 ' ' 2 NQ C ' ' 12 -99 ' ' 6 F R4 1 13 -99 ' ' 2 NQ C ' ' 14 -99 ' ' 6 F R4 1 15 -99 ' ' 2 NQ C ' ' 16 -99 ' ' 7 F R4 2 17 -99 ' ' 2 NQ C ' ' 18 -99 ' ' 7 F R4 2 19 -99 ' ' 2 NQ C ' ' 20 -99 ' ' 8 F ' ' 3 21 -99 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- Comments from secondary file: H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.clnadd -------------------------------------------------------------------------------------- Raw data in file oxydata\2004-10-\2004-10-0002.o2 VIO3 = 9.98 ! Volume of iodate standard (cm**) NIO3 = .01013 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) $END *ADMINISTRATION MISSION : 2004-10 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : N.E. Pacific STATION : P2 EVENT NUMBER : 2 LATITUDE : 48 35.93000 N ! (deg min) LONGITUDE : 126 0.16000 W ! (deg min) WATER DEPTH : 118 ALTIMETER (M) : 6.085 ! custom item $REMARKS Altimeter value is distance from bottom and is calculated as the median of the deepest 2 metres of data. $END *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2023 conductivity:primary ' ' 1763 pressure ' ' 77511 temperature:secondary ' ' 2095 conductivity:secondary ' ' 1764 Fluorometer ' ' Seapoint Oxygen:SBE ' ' 0047 transmissometer:primary ' ' 333DR irradiance ' ' primary altimeter: ' ' ' ' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.30A Comments from secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.add ------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. Comments from secondary file: H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.clnadd ---------------------------------------------------------- $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/08/02 13:50:53 968 968 CLEAN 4.7 2004/08/02 13:52:12 ? ? ADDSAMP 3.4 2004/08/04 17:31:53 968 968 BINAVE 4.0.1 2004/08/04 17:34:08 968 8 MERGE 3.1 2004/08/05 08:47:51 8 8 MERGE 3.1 2004/08/05 08:56:18 8 8 CALIB 11.4 2004/08/13 14:37:12 8 8 CLEAN 4.7 2004/08/17 12:47:02 ? ? SORT 3.4.1 2004/08/17 12:49:24 8 8 REMOVECH 6.0 2004/08/17 12:53:52 8 8 HDREDIT2 2.2 2004/08/17 13:01:51 ? ? CALIB 11.4 2004/09/29 14:45:36 8 8 SORT 3.5 2004/11/03 15:51:05 8 8 MERGE 3.3 2004/11/03 15:51:50 8 8 SORT 3.5 2004/11/03 16:00:22 8 8 HDREDIT2 2.3 2004/12/07 14:36:58 ? ? REMOVECH 6.0 2005/02/04 11:29:31 8 8 REMOVECH 7.0 2005/09/19 16:20:41 8 8 SORT 3.5 2005/09/19 16:21:42 8 8 MERGE 3.3 2005/09/19 16:22:49 8 8 SORT 3.5 2005/09/19 16:34:26 8 8 CALIB 11.6 2005/10/12 13:52:11 8 8 HDREDIT2 2.5 2005/11/04 10:57:59 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:29:39 8 8 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:30:14 8 8 CHANGE_FLAGS 2.0 2014/11/20 09:54:17 8 8 CLEAN 5.3 2024/04/15 14:49:32 8 8 CLEAN 5.3 2024/04/15 14:49:49 8 8 CLEAN 5.3 2024/04/15 14:52:35 8 8 HDREDIT2 3.2 2024/04/15 14:55:01 ? ? $END $REMARKS -CLEAN functions: Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2004-10\CTD files\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.samavg Secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.sal -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.mrg1 Secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.add Comments from secondary file: Q:\Cruise_Data\2004-10\CTD files\hydro\2004-10-0002.add ------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2004-10\CTD files\doc\2004-10-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Oxygen:Dissolved:SBE mL/L 10 0.3310000E-01 0.1077200E+01 17 Salinity:T0:C0 PSS-78 10 0.1000000E-02 0.1000000E+01 -CLEAN functions: Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Oxygen:Voltage:SBE Status:Pump Altimeter Descent_Rate Salinity:T1:C1 Flag -HEADER EDITS: Applied edit header: O:\Data Processing\Header Comments\sal_oxy_chl_fresh_nut_a Channel 1: Sample_Number [n/a] Pad: -9 ==> -99 Channel 2: Pressure [decibar] Units ==> dbars Format: F10.3 ==> F7.1 Channel 3: Temperature:Primary [deg C (ITS90)] (no changes) Channel 4: Transmissivity [%/metre] (no changes) Channel 5: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 6: PAR [uE/m^2/sec] Format: F11.3 ==> F7.1 Channel 7: Fluorescence:URU:Seapoint [mg/m^3] (no changes) Channel 8: Bottle_Number [n/a] (no changes) Channel 9: Salinity:T0:C0 [PSS-78] (no changes) Channel 10: Number_of_bin_records [n/a] Format: F5.0 ==> I5 Channel 11: Salinity:Bottle [] Units ==> PSS-78 Channel 12: Flag:Salinity:Bottle [] Units ==> n/a Pad: 0 ==> blank Channel 13: Oxygen:Dissolved [mL/L] (no changes) Channel 14: Flag:Oxygen:Dissolved [] Units ==> n/a Pad: 0 ==> blank -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2004-10\DOC new\2004-10-recal3.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Salinity:T0:C0 PSS-78 10 0.5000000E-03 0.1000000E+01 -SORT parameters: 2004/11/03 15:51:05 Sorted in descending order of channel Sample_Number -The following MERGE parameters were used: 2004/11/03 15:51:50 Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Chlorophyll:Extracted, Flag:Chlorophyll:Extracted Primary file : H:\Data Processing\2004\2004-10\2004-10-0002.srt_che Secondary file: H:\Data Processing\2004\2004-10\2004-10-0002.mrg Comments from secondary file: H:\Data Processing\2004\2004-10\2004-10-0002.mrg ------------------------------------------------ -The following MERGE parameters were used: 2004/11/03 14:59:15 Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Chlorophyll:Extracted, Flag:Chlorophyll:Extracted Primary file : H:\Data Processing\2004\2004-10\2004-10-0002.nut Secondary file: H:\Data Processing\2004\2004-10\2004-10-0002.chl -SORT parameters: 2004/11/03 16:00:22 Sorted in ascending order of channel Pressure -HEADER EDITS: 2004/12/07 14:36:58 Applied edit header: H:\STNPCHEM\Work\HEADERS\Geographic Area.txt -The following CHANNEL(S) were removed from file. PAR -REMOVECH 2005/09/19 16:20:41 The following CHANNEL(S) were removed: Oxygen:Dissolved [mL/L] Flag:Oxygen:Dissolved -SORT parameters: 2005/09/19 16:21:42 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2005/09/19 16:22:49 Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.srtrem Secondary file: H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.clnadd Comments from secondary file: H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.clnadd ---------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.002 Sodium Thiosulfate concentration = 0.715 Volume of iodate standard (cm**3) = 9.98 Enter Normalitity of iodate standard = 0.01013000 -CLEAN functions: 2005/09/19 16:22:17 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. -SORT parameters: 2005/09/19 16:34:26 -CALIB parameters: 2005/10/12 13:52:11 -HEADER EDITS: 2005/11/04 10:57:59 -CLEAN functions: 2024/04/15 14:49:32 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Set header Start and End times from the data. *FAILED* -CLEAN functions: 2024/04/15 14:49:49 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Set header Start and End times from the data. *FAILED* -CLEAN functions: 2024/04/15 14:52:35 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. Insert Pad Values in Channel: Oxygen:Dissolved [mL/L] where channel Oxygen:Dissolved [mL/L] is in the range -99.99 to -99.99 0 data records in pad range. Set header Start and End times from the data. *FAILED* -HEADER EDITS: 2024/04/15 14:55:01 - none. $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. Comments from secondary file: H:\Data Processing\Oxygen redo\2004-10\2004-10-0002.clnadd ---------------------------------------------------------- This cast was run through the DOXX program to change the standard values *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- -------- ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.331E-01 1.0772) Salinity:T0:C0 PSS-78 10 -99 () (0.1E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.5E-03 1) Oxygen:Dissolved:SBE mL/L 10 -99 () (0 1.005) $END !-1-- --2--- ---3---- --4-- --5--- ---6--- 7- ---8---- -9-- ---10--- - --12- - --14- - --16-- - --18-- - ---20-- - !Samp Pressu Temperat Trans Oxygen Fluores Bo Salinity Numb Salinity F Nitra F Silic F Phosph F Chloro F Oxygen: F !le_ re ure: missi : cence: tt :T0:C0 er_o :Bottle l te_ l ate l ate l phyll: l Dissolv l !Numb Primary vity Dissol URU: ~u ~bin ~ plus_ ~ ~ ~ Extrac ~ ed ~ !er ved: Seapoin mb _rec l Nitri t t t ted e e ! SBE t er ords e te e e e d d !---- ------ -------- ----- ------ ------- -- -------- ---- -------- - ----- - ----- - ------ - ------ - ------- - *END OF HEADER 2 112.9 7.1134 50.1 2.33 0.136 1 33.7835 121 33.7862 0 32.0 0 47.4 0 2.42 0 -99.00 0 2.295 0 3 97.2 7.3399 53.7 2.29 0.139 2 33.6390 121 33.6273 0 31.7 0 45.9 0 2.41 0 0.02 0 2.227 0 4 76.7 7.6644 58.6 4.78 0.167 3 33.0724 121 33.0662 0 19.9 0 23.6 0 1.59 0 0.04 0 4.756 0 5 76.1 7.6725 58.6 4.78 0.167 4 33.0657 121 33.0626 0 19.8 0 23.5 0 1.60 0 0.04 0 4.755 0 6 50.3 8.2508 57.9 5.86 0.307 5 32.5956 121 32.5874 0 12.3 0 14.1 0 1.19 0 0.15 0 5.861 0 7 25.6 9.3319 49.4 6.34 1.949 6 32.3205 121 32.3138 0 6.5 0 9.0 0 0.90 0 1.34 0 6.344 0 8 10.7 13.6882 49.3 6.49 0.548 7 31.4640 121 31.4600 0 0.0 0 0.6 0 0.27 0 0.33 0 6.419 0 9 5.9 13.7712 49.3 6.47 0.541 8 31.4542 121 31.4563 0 0.0 0 0.6 0 0.27 0 0.36 0 6.363 0