*2014/11/20 09:54:12.62 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2004/04/29 05:20:16.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 10 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 5 5 2 Pressure decibar 338.165 338.165 3 Temperature:Primary 'deg C (ITS90)' 9.4957 9.4957 4 Fluorescence:URU:Seapoint mg/m^3 1.375 1.375 5 Oxygen:Dissolved:SBE mL/L 2.229122 2.229122 6 Salinity:T0:C0 PSS-78 31.0244 31.0244 7 Bottle_Number n/a 1 1 8 Number_of_bin_records n/a 121 121 9 Salinity:Bottle PSS-78 31.0242 31.0242 10 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -9 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 7 F ' ' 2 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 3 I I 0 8 -99 ' ' 5 I I 0 9 -99 ' ' 9 F R4 4 10 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2004-07 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : LaPerouse/Co-variability/ECOHAB/GURD/JdeF/SoG SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI / SoG / JdeF STATION : VI03 EVENT NUMBER : 15 LATITUDE : 49 5.96000 N ! (deg min) LONGITUDE : 123 28.96000 W ! (deg min) WATER DEPTH : 340 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2023 conductivity:primary ' ' 1763 pressure ' ' 77511 temperature:secondary ' ' 2095 conductivity:secondary ' ' 1764 Fluorometer ' ' Seapoint Oxygen:SBE ' ' 0047 transmissometer:primary ' ' 333DR $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.30A $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/06/23 14:01:36 121 121 CLEAN 4.6.3 2004/06/23 14:24:50 ? ? ADDSAMP 3.4 2004/06/25 09:14:05 121 121 BINAVE 4.0.1 2004/06/25 09:14:41 121 1 MERGE 3.1 2004/06/25 09:19:51 1 1 MERGE 3.1 2004/06/25 14:44:22 1 1 CALIB 11.4 2004/06/29 09:58:57 1 1 CLEAN 4.6.3 2004/06/29 12:09:26 ? ? SORT 3.4.1 2004/06/29 12:09:43 1 1 REMOVECH 6.0 2004/06/29 13:41:40 1 1 HDREDIT2 2.2 2004/06/29 13:55:29 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:29:35 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:29:58 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:54:12 1 1 $END $REMARKS -CLEAN functions: Set event to last 4 characters of file name -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2004-07\CTD\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2004-07\ctd\hydro\2004-07-0015.samavg Secondary file: Q:\Cruise_Data\2004-07\ctd\hydro\2004-07-0015.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2004-07\CTD\hydro\2004-07-0015.mrg1 Secondary file: Q:\Cruise_Data\2004-07\CTD\hydro\2004-07-0015.add1 -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2004-07\ctd\doc\2004-07-recal1.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 10 Oxygen:Dissolved:SBE mL/L 10 0.7510000E-01 0.1033600E+01 -CLEAN functions: Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Transmissivity Salinity:T1:C1 Oxygen:Voltage:SBE Status:Pump Descent_Rate Flag -HEADER EDITS: Applied edit header: Q:\Cruise_Data\2004-07\CTD\doc\2004-07-bot-HDR.TXT Channel 1: Sample_Number [n/a] (no changes) Channel 2: Pressure [decibar] Units ==> dbars Format: F10.3 ==> F7.1 Channel 3: Temperature:Primary [deg C (ITS90)] (no changes) Channel 4: Fluorescence:URU:Seapoint [mg/m^3] (no changes) Channel 5: Oxygen:Dissolved:SBE [mL/L] Format: F8.3 ==> F7.2 Channel 6: Salinity:T0:C0 [PSS-78] (no changes) Channel 7: Bottle_Number [n/a] (no changes) Channel 8: Number_of_bin_records [n/a] Format: F5.0 ==> I5 Pad: ' ' ==> -99 Channel 9: Salinity:Bottle [] Units ==> PSS-78 Channel 10: Flag:Salinity:Bottle [] (no changes) $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. ------------------------------------------------------------------------------ The fluorescence and transmissivity data are nominal and unedited except that some records were removed in editing T and S. For casts #1 through #37 the transmissivity was bad or missing so the channel was removed from the files. The SBE dissolved oxygen data should be considered: • ±0.2ml/l from 0db–350db. • ±0.05ml/l below 350db – 1000db • unreliable below 1500db *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (0.751E-01 1.0336) $END !-1-- --2--- ---3---- ---4--- --5--- ---6---- 7- -8-- ---9---- - !Samp Pressu Temperat Fluores Oxygen Salinity Bo Numb Salinity F !le_ re ure: cence: : :T0:C0 tt er_o :Bottle l !Numb Primary URU: Dissol ~u ~bin ~ !er Seapoin ved: mb _rec l ! t SBE er ords e !---- ------ -------- ------- ------ -------- -- ---- -------- - *END OF HEADER 5 338.2 9.4957 1.375 2.23 31.0244 1 121 31.0242 0