*2013/12/16 15:28:38.18 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/06/04 03:17:49.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 18 DATA DESCRIPTION : CTD FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 4.2 20.8 2 Temperature:Primary 'deg C (ITS90)' 9.8627 10.5627 3 Transmissivity %/metre 28.1 32.2 4 Fluorescence:URU:Seapoint mg/m^3 0.21E-01 1.419 5 Salinity:T0:C0 PSS-78 31.6921 31.7429 6 Number_of_bin_records n/a 23 43 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 9 F ' ' 4 6 ' ' ' ' 5 I I 0 $END $REMARKS This file converted from Sea-Bird file: Q:\Cruise_Data\2003-25\Hecate_Strait\ $END *ADMINISTRATION MISSION : 2003-25 AGENCY : PBS, Stock Assessment, Nanaimo, B.C. COUNTRY : Canada PROJECT : Hecate Strait Multi-Species Survey SCIENTIST : Workman G. PLATFORM : W.E. Ricker *LOCATION GEOGRAPHIC AREA : Hecate Strait STATION : J3 EVENT NUMBER : 35 LATITUDE : 52 54.47000 N ! (deg min) LONGITUDE : 131 13.48000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2424 pressure ' ' 69698 temperature:secondary ' ' 2374 conductivity:secondary ' ' 2399 Fluorometer ' ' Seapoint transmissometer:primary ' ' 197 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/03/08 14:59:50 3603 3603 CLEAN 4.5 2004/03/08 15:12:35 3602 3602 SHIFTDAT 3.3 2004/03/16 15:06:02 ? ? SHIFTDAT 3.3 2004/03/16 15:10:08 ? ? DELETE 6.3 2004/03/16 15:13:38 3602 676 CTDEDIT 4.50 2004/03/19 17:53:41 676 622 CTDEDIT 4.50 2004/03/22 13:27:02 622 622 CALIB 11.4 2004/03/22 13:28:14 622 622 FILTERS 4.3 2004/03/22 13:28:23 622 622 BINAVE 4.0.1 2004/03/22 13:28:41 622 18 REMOVECH 6.0 2004/03/22 13:41:01 18 18 HDREDIT2 1.9 2004/03/22 14:15:45 ? ? HDREDIT2 1.9 2004/03/29 10:58:40 ? ? CALIB 11.4 2004/12/22 12:03:41 18 18 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:38 18 18 $END $REMARKS CLEAN functions: - Interpolation by Record Number, in Pressure -The following SHIFT parameters were used. Shift Channel: Conductivity:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= -1.10 Salinity was recalculated after shift -The following SHIFT parameters were used. Shift Channel: Fluorescence:URU:Seapoint # of Records to Advance (-ve for Delay): At REC# 0 Shift= 24.00 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 5.000 Surface Swell Pressure Tolerance: 1.00 Pressure filtered over width: 15 Swells deleted. Warning message if pressure difference of 2.00 Drop rates < 0.30m/s (calculated over 11 points) will be deleted. Drop rate applies in the range 10.00 to 11.64 dbars Sample interval (from FILE section of header) = 0.042 seconds. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-25\ctd\doc\2003-25-RECAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Salinity:T0:C0 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following FILTER parameters were used. Median filter was used. Filter width = 11 The following channel(s) were filtered. Fluorescence:URU:Seapoint -The following BINAVE parameters were used: Bin channel = Pressure Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Descent_Rate Status:Pump Salinity:T1:C1 Flag -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\RICKER recal\2003-25\2003-25-RECAL2.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.1500000E-02 0.1000000E+01 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\data\20030025\20030025035.dat Software Version Seasave Win32 V 5.27c Temperature SN = 2668 Conductivity SN = 2424 Number of Bytes Per Scan = 24 Number of Voltage Words = 2 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Jun 04 2003 05:12:07 NMEA Latitude = 52 54.47 N NMEA Longitude = 131 13.48 W NMEA UTC (Time) = Jun 04 2003 03:17:49 Store Lat/Lon Data = Add to Header Only Ship: W.E Ricker WE RICKER Cruise: 2003-04 2003-25 Station: J3 Latitude: 52 54.48 Longitude: 131 13.48 Depth 24 # nquan = 13 # nvalues = 3603 # units = specified # name 0 = scan: Scan Count # name 1 = prDM: Pressure, Digiquartz [db] # name 2 = t090C: Temperature [ITS-90, deg C] # name 3 = t190C: Temperature, 2 [ITS-90, deg C] # name 4 = c0S/m: Conductivity [S/m] # name 5 = c1S/m: Conductivity, 2 [S/m] # name 6 = xmiss: Beam Transmission, Chelsea/Seatech/Wetlab CStar [%] # name 7 = flSP: Fluorescence, Seapoint # name 8 = dz/dtM: Descent Rate [m/s] # name 9 = pumps: Pump Status # name 10 = sal00: Salinity [PSU] # name 11 = sal11: Salinity, 2 [PSU] # name 12 = flag: flag # span 0 = 1, 3603 # span 1 = 3.152, 21.644 # span 2 = 9.8616, 11.0315 # span 3 = 9.8630, 11.0671 # span 4 = 3.439539, 3.575680 # span 5 = 3.488099, 3.675951 # span 6 = 66.0006, 75.3266 # span 7 = 1.0989e-02, 1.8974e+00 # span 8 = -0.736, 0.773 # span 9 = 0, 1 # span 10 = 30.5401, 31.9457 # span 11 = 31.2357, 33.0176 # span 12 = 0.0000e+00, 0.0000e+00 # interval = seconds: 0.0416667 # start_time = Jun 04 2003 05:12:07 # bad_flag = -9.990e-29 # sensor 0 = Frequency 0 temperature, primary, 2668, 20-Jun-02s # sensor 1 = Frequency 1 conductivity, primary, 2424, 16-Apr-02, cpcor = -9.57 00e-08 # sensor 2 = Frequency 2 pressure, 69698, 11-12-1997 # sensor 3 = Frequency 3 temperature, secondary, 2374, 20-Jun-02 # sensor 4 = Frequency 4 conductivity, secondary, 2399, 16-Apr-02, cpcor = -9. 5700e-08 # sensor 5 = Extrnl Volt 0 Fluorometer, Seapoint, primary # sensor 6 = Extrnl Volt 2 transmissometer, primary, 197, 22-Jan-03 # datcnv_date = Mar 08 2004 14:09:28, 5.30a # datcnv_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\2003-25-0035.dat Q:\Cruis e_Data\2003-25\Hecate_Strait\CTD\2003-25-ctd.con # datcnv_skipover = 0 # wildedit_date = Mar 08 2004 14:10:48, 5.30a # wildedit_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\convert\2003-25-0035.cn v # wildedit_pass1_nstd = 2.0 # wildedit_pass2_nstd = 5.0 # wildedit_pass2_mindelta = 0.000e+000 # wildedit_npoint = 50 # wildedit_vars = prDM # wildedit_excl_bad_scans = yes # alignctd_date = Mar 08 2004 14:11:52, 5.30a # alignctd_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\wildedit\2003-25-0035.c nv # alignctd_adv = c1S/m 0.073 # celltm_date = Mar 08 2004 14:13:27, 5.30a # celltm_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\align\2003-25-0035.cnv # celltm_alpha = 0.0200, 0.0300 # celltm_tau = 7.0000, 9.0000 # celltm_temp_sensor_use_for_cond = primary, secondary # Derive_date = Mar 08 2004 14:16:22, 5.30a # Derive_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\celltm\2003-25-0035.cnv Q :\Cruise_Data\2003-18\2003-18-CTD1.CON # file_type = ascii END* CTDEDIT was used to remove surface records to 3.9db and to clean salinity very heavily. CTDEDIT was used a second time to clean salinity more. -------------------------------------------------------------------- There were no salinity calibration samples for this cruise. The recalibration of salinity is based on the results of other cruises using the same equipment; the calibration sampling for those cruises was limited and there is evidence of drift in the calibration. There was a lot of fine-scale noise in the salinity channel. Salinity should be considered +/- 0.005psu. Transmissivity - The data are nominal and unedited. Fluorescence - The data are nominal and unedited. -------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.5E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.15E-02 1) $END !--1--- ---2---- --3-- ---4--- ---5---- -6-- !Pressu Temperat Trans Fluores Salinity Numb !re ure: missi cence: :T0:C0 er_o ! Primary vity URU: ~bin ! Seapoin _rec ! t ords !------ -------- ----- ------- -------- ---- *END OF HEADER 4.2 10.5627 28.2 0.021 31.6924 26 5.0 10.4796 29.3 0.024 31.6921 43 6.0 10.3990 28.9 0.022 31.6969 34 7.0 10.3835 28.9 0.024 31.7027 34 8.0 10.3375 28.7 0.028 31.6990 31 9.0 10.2637 28.1 0.026 31.7059 35 10.0 10.2003 28.5 0.041 31.7141 36 11.0 10.1660 28.3 0.162 31.7197 35 12.0 10.0918 28.5 0.323 31.7219 36 13.0 9.9196 29.6 0.451 31.7313 34 14.0 9.9025 30.5 0.706 31.7384 36 15.0 9.9125 30.8 1.031 31.7403 33 16.0 9.8915 31.3 1.158 31.7401 33 17.0 9.8808 31.4 1.178 31.7403 36 18.0 9.8798 31.6 1.419 31.7429 36 19.0 9.8701 31.8 1.319 31.7415 41 20.0 9.8687 32.0 1.280 31.7424 40 20.8 9.8627 32.2 1.234 31.7427 23