*2013/12/16 15:28:38.03 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/06/03 04:40:07.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 16 DATA DESCRIPTION : CTD FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 3.3 17.6 2 Temperature:Primary 'deg C (ITS90)' 9.6997 10.0734 3 Transmissivity %/metre 21.6 26.3 4 Fluorescence:URU:Seapoint mg/m^3 0.16E-01 2.604 5 Salinity:T0:C0 PSS-78 31.8991 31.9078 6 Number_of_bin_records n/a 8 42 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 9 F ' ' 4 6 ' ' ' ' 5 I I 0 $END $REMARKS This file converted from Sea-Bird file: Q:\Cruise_Data\2003-25\Hecate_Strait\ $END *ADMINISTRATION MISSION : 2003-25 AGENCY : PBS, Stock Assessment, Nanaimo, B.C. COUNTRY : Canada PROJECT : Hecate Strait Multi-Species Survey SCIENTIST : Workman G. PLATFORM : W.E. Ricker *LOCATION GEOGRAPHIC AREA : Hecate Strait STATION : I2 EVENT NUMBER : 30 LATITUDE : 53 5.05000 N ! (deg min) LONGITUDE : 131 22.87000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2424 pressure ' ' 69698 temperature:secondary ' ' 2374 conductivity:secondary ' ' 2399 Fluorometer ' ' Seapoint transmissometer:primary ' ' 197 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/03/08 14:59:28 3067 3067 CLEAN 4.5 2004/03/08 15:11:59 3067 3067 SHIFTDAT 3.3 2004/03/16 15:05:29 ? ? SHIFTDAT 3.3 2004/03/16 15:09:36 ? ? DELETE 6.3 2004/03/16 15:13:11 3067 443 CTDEDIT 4.50 2004/03/19 16:25:52 443 443 CALIB 11.4 2004/03/22 12:23:27 443 443 FILTERS 4.3 2004/03/22 12:59:21 443 443 BINAVE 4.0.1 2004/03/22 13:05:33 443 16 REMOVECH 6.0 2004/03/22 13:41:00 16 16 HDREDIT2 1.9 2004/03/22 14:15:44 ? ? HDREDIT2 1.9 2004/03/29 10:58:19 ? ? CALIB 11.4 2004/12/22 12:03:40 16 16 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:38 16 16 $END $REMARKS CLEAN functions: - Interpolation by Record Number, in Pressure -The following SHIFT parameters were used. Shift Channel: Conductivity:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= -1.10 Salinity was recalculated after shift -The following SHIFT parameters were used. Shift Channel: Fluorescence:URU:Seapoint # of Records to Advance (-ve for Delay): At REC# 0 Shift= 24.00 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 5.000 Surface Swell Pressure Tolerance: 1.00 Pressure filtered over width: 15 Swells deleted. Warning message if pressure difference of 2.00 Drop rates < 0.30m/s (calculated over 11 points) will be deleted. Drop rate applies in the range 10.00 to 8.00 dbars Sample interval (from FILE section of header) = 0.042 seconds. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-25\ctd\doc\2003-25-RECAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Salinity:T0:C0 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following FILTER parameters were used. Median filter was used. Filter width = 11 The following channel(s) were filtered. Fluorescence:URU:Seapoint -The following BINAVE parameters were used: Bin channel = Pressure Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Descent_Rate Status:Pump Salinity:T1:C1 Flag -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\RICKER recal\2003-25\2003-25-RECAL2.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.1500000E-02 0.1000000E+01 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\data\20030025\20030025030.dat Software Version Seasave Win32 V 5.27c Temperature SN = 2668 Conductivity SN = 2424 Number of Bytes Per Scan = 24 Number of Voltage Words = 2 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Jun 03 2003 06:34:30 NMEA Latitude = 53 05.05 N NMEA Longitude = 131 22.87 W NMEA UTC (Time) = Jun 03 2003 04:40:07 Store Lat/Lon Data = Add to Header Only Ship: W.E Ricker WE RICKER Cruise: 2003-04 2003-25 Station: I2 Latitude: 53 05.05 Longitude: 131 22.88 Depth 20 # nquan = 13 # nvalues = 3067 # units = specified # name 0 = scan: Scan Count # name 1 = prDM: Pressure, Digiquartz [db] # name 2 = t090C: Temperature [ITS-90, deg C] # name 3 = t190C: Temperature, 2 [ITS-90, deg C] # name 4 = c0S/m: Conductivity [S/m] # name 5 = c1S/m: Conductivity, 2 [S/m] # name 6 = xmiss: Beam Transmission, Chelsea/Seatech/Wetlab CStar [%] # name 7 = flSP: Fluorescence, Seapoint # name 8 = dz/dtM: Descent Rate [m/s] # name 9 = pumps: Pump Status # name 10 = sal00: Salinity [PSU] # name 11 = sal11: Salinity, 2 [PSU] # name 12 = flag: flag # span 0 = 1, 3067 # span 1 = 2.727, 17.999 # span 2 = 9.6974, 10.5073 # span 3 = 9.6980, 10.4784 # span 4 = 3.478803, 3.550870 # span 5 = 3.486752, 3.615078 # span 6 = 52.7759, 71.6828 # span 7 = 7.3260e-03, 2.6630e+00 # span 8 = -0.742, 0.956 # span 9 = 0, 1 # span 10 = 31.7901, 31.9615 # span 11 = 31.8218, 32.8011 # span 12 = 0.0000e+00, 0.0000e+00 # interval = seconds: 0.0416667 # start_time = Jun 03 2003 06:34:30 # bad_flag = -9.990e-29 # sensor 0 = Frequency 0 temperature, primary, 2668, 20-Jun-02s # sensor 1 = Frequency 1 conductivity, primary, 2424, 16-Apr-02, cpcor = -9.57 00e-08 # sensor 2 = Frequency 2 pressure, 69698, 11-12-1997 # sensor 3 = Frequency 3 temperature, secondary, 2374, 20-Jun-02 # sensor 4 = Frequency 4 conductivity, secondary, 2399, 16-Apr-02, cpcor = -9. 5700e-08 # sensor 5 = Extrnl Volt 0 Fluorometer, Seapoint, primary # sensor 6 = Extrnl Volt 2 transmissometer, primary, 197, 22-Jan-03 # datcnv_date = Mar 08 2004 14:09:23, 5.30a # datcnv_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\2003-25-0030.dat Q:\Cruis e_Data\2003-25\Hecate_Strait\CTD\2003-25-ctd.con # datcnv_skipover = 0 # wildedit_date = Mar 08 2004 14:10:41, 5.30a # wildedit_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\convert\2003-25-0030.cn v # wildedit_pass1_nstd = 2.0 # wildedit_pass2_nstd = 5.0 # wildedit_pass2_mindelta = 0.000e+000 # wildedit_npoint = 50 # wildedit_vars = prDM # wildedit_excl_bad_scans = yes # alignctd_date = Mar 08 2004 14:11:45, 5.30a # alignctd_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\wildedit\2003-25-0030.c nv # alignctd_adv = c1S/m 0.073 # celltm_date = Mar 08 2004 14:13:21, 5.30a # celltm_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\align\2003-25-0030.cnv # celltm_alpha = 0.0200, 0.0300 # celltm_tau = 7.0000, 9.0000 # celltm_temp_sensor_use_for_cond = primary, secondary # Derive_date = Mar 08 2004 14:16:15, 5.30a # Derive_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\celltm\2003-25-0030.cnv Q :\Cruise_Data\2003-18\2003-18-CTD1.CON # file_type = ascii END* CTDEDIT was used to clean salinity. -------------------------------------------------------------------- There were no salinity calibration samples for this cruise. The recalibration of salinity is based on the results of other cruises using the same equipment; the calibration sampling for those cruises was limited and there is evidence of drift in the calibration. There was a lot of fine-scale noise in the salinity channel. Salinity should be considered +/- 0.005psu. Transmissivity - The data are nominal and unedited. Fluorescence - The data are nominal and unedited. -------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.5E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.15E-02 1) $END !--1--- ---2---- --3-- ---4--- ---5---- -6-- !Pressu Temperat Trans Fluores Salinity Numb !re ure: missi cence: :T0:C0 er_o ! Primary vity URU: ~bin ! Seapoin _rec ! t ords !------ -------- ----- ------- -------- ---- *END OF HEADER 3.3 10.0734 21.6 0.016 31.9041 16 4.0 10.0276 24.5 0.022 31.9025 42 5.0 9.9928 24.9 0.020 31.9004 34 6.0 9.9562 25.2 0.020 31.8991 28 7.0 9.8348 25.2 0.021 31.9000 29 8.0 9.7983 25.3 0.023 31.9009 31 9.0 9.7707 25.5 0.028 31.9023 29 10.0 9.7617 25.5 0.042 31.9028 29 11.0 9.7486 25.6 0.260 31.9041 31 12.0 9.7350 25.8 1.090 31.9052 31 13.0 9.7228 25.8 1.534 31.9064 28 14.0 9.7202 26.1 2.020 31.9065 26 15.0 9.7115 26.0 2.375 31.9071 26 16.0 9.7044 26.0 2.502 31.9077 27 17.0 9.7008 26.2 2.604 31.9078 28 17.6 9.6997 26.3 2.571 31.9078 8