*2013/12/16 15:28:37.90 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/06/02 06:55:22.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 26 DATA DESCRIPTION : CTD FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 5.1 29.7 2 Temperature:Primary 'deg C (ITS90)' 9.7081 9.9983 3 Transmissivity %/metre 25.8 28.8 4 Fluorescence:URU:Seapoint mg/m^3 0.27E-01 3.912 5 Salinity:T0:C0 PSS-78 31.8385 31.8417 6 Number_of_bin_records n/a 12 43 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 9 F ' ' 4 6 ' ' ' ' 5 I I 0 $END $REMARKS This file converted from Sea-Bird file: Q:\Cruise_Data\2003-25\Hecate_Strait\ $END *ADMINISTRATION MISSION : 2003-25 AGENCY : PBS, Stock Assessment, Nanaimo, B.C. COUNTRY : Canada PROJECT : Hecate Strait Multi-Species Survey SCIENTIST : Workman G. PLATFORM : W.E. Ricker *LOCATION GEOGRAPHIC AREA : Hecate Strait STATION : H2 EVENT NUMBER : 26 LATITUDE : 53 15.07000 N ! (deg min) LONGITUDE : 131 23.12000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2424 pressure ' ' 69698 temperature:secondary ' ' 2374 conductivity:secondary ' ' 2399 Fluorometer ' ' Seapoint transmissometer:primary ' ' 197 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/03/08 14:59:11 4963 4963 CLEAN 4.5 2004/03/08 15:11:32 4961 4961 SHIFTDAT 3.3 2004/03/16 15:05:05 ? ? SHIFTDAT 3.3 2004/03/16 15:09:11 ? ? DELETE 6.3 2004/03/16 15:12:52 4961 975 CTDEDIT 4.50 2004/03/19 15:47:42 975 760 CALIB 11.4 2004/03/22 12:23:17 760 760 FILTERS 4.3 2004/03/22 12:59:12 760 760 BINAVE 4.0.1 2004/03/22 13:05:28 760 26 REMOVECH 6.0 2004/03/22 13:41:00 26 26 HDREDIT2 1.9 2004/03/22 14:15:44 ? ? HDREDIT2 1.9 2004/03/29 10:58:06 ? ? CALIB 11.4 2004/12/22 12:03:39 26 26 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:37 26 26 $END $REMARKS CLEAN functions: - Interpolation by Record Number, in Pressure -The following SHIFT parameters were used. Shift Channel: Conductivity:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= -1.10 Salinity was recalculated after shift -The following SHIFT parameters were used. Shift Channel: Fluorescence:URU:Seapoint # of Records to Advance (-ve for Delay): At REC# 0 Shift= 24.00 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 5.000 Surface Swell Pressure Tolerance: 1.00 Pressure filtered over width: 15 Swells deleted. Warning message if pressure difference of 2.00 Drop rates < 0.30m/s (calculated over 11 points) will be deleted. Drop rate applies in the range 10.00 to 20.06 dbars Sample interval (from FILE section of header) = 0.042 seconds. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-25\ctd\doc\2003-25-RECAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Salinity:T0:C0 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following FILTER parameters were used. Median filter was used. Filter width = 11 The following channel(s) were filtered. Fluorescence:URU:Seapoint -The following BINAVE parameters were used: Bin channel = Pressure Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Descent_Rate Status:Pump Salinity:T1:C1 Flag -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\RICKER recal\2003-25\2003-25-RECAL2.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.1500000E-02 0.1000000E+01 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\data\20030025\20030025026.dat Software Version Seasave Win32 V 5.27c Temperature SN = 2668 Conductivity SN = 2424 Number of Bytes Per Scan = 24 Number of Voltage Words = 2 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Jun 02 2003 08:49:51 NMEA Latitude = 53 15.07 N NMEA Longitude = 131 23.12 W NMEA UTC (Time) = Jun 02 2003 06:55:22 Store Lat/Lon Data = Add to Header Only Ship: W.E Ricker WE RICKER Cruise: 2003-04 2003-25 Station: H2 Latitude: 53 15.08 Longitude: 131 23.12 Depth 33 # nquan = 13 # nvalues = 4963 # units = specified # name 0 = scan: Scan Count # name 1 = prDM: Pressure, Digiquartz [db] # name 2 = t090C: Temperature [ITS-90, deg C] # name 3 = t190C: Temperature, 2 [ITS-90, deg C] # name 4 = c0S/m: Conductivity [S/m] # name 5 = c1S/m: Conductivity, 2 [S/m] # name 6 = xmiss: Beam Transmission, Chelsea/Seatech/Wetlab CStar [%] # name 7 = flSP: Fluorescence, Seapoint # name 8 = dz/dtM: Descent Rate [m/s] # name 9 = pumps: Pump Status # name 10 = sal00: Salinity [PSU] # name 11 = sal11: Salinity, 2 [PSU] # name 12 = flag: flag # span 0 = 1, 4963 # span 1 = 0.540, 30.064 # span 2 = 9.7078, 10.0368 # span 3 = 9.7075, 10.1758 # span 4 = 0.073159, 3.506201 # span 5 = 0.044294, 3.529231 # span 6 = 0.7435, 73.4410 # span 7 = 0.0000e+00, 5.6923e+00 # span 8 = -0.816, 0.943 # span 9 = 0, 1 # span 10 = 0.5095, 31.8937 # span 11 = 0.3027, 32.1518 # span 12 = 0.0000e+00, 0.0000e+00 # interval = seconds: 0.0416667 # start_time = Jun 02 2003 08:49:51 # bad_flag = -9.990e-29 # sensor 0 = Frequency 0 temperature, primary, 2668, 20-Jun-02s # sensor 1 = Frequency 1 conductivity, primary, 2424, 16-Apr-02, cpcor = -9.57 00e-08 # sensor 2 = Frequency 2 pressure, 69698, 11-12-1997 # sensor 3 = Frequency 3 temperature, secondary, 2374, 20-Jun-02 # sensor 4 = Frequency 4 conductivity, secondary, 2399, 16-Apr-02, cpcor = -9. 5700e-08 # sensor 5 = Extrnl Volt 0 Fluorometer, Seapoint, primary # sensor 6 = Extrnl Volt 2 transmissometer, primary, 197, 22-Jan-03 # datcnv_date = Mar 08 2004 14:09:19, 5.30a # datcnv_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\2003-25-0026.dat Q:\Cruis e_Data\2003-25\Hecate_Strait\CTD\2003-25-ctd.con # datcnv_skipover = 0 # wildedit_date = Mar 08 2004 14:10:35, 5.30a # wildedit_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\convert\2003-25-0026.cn v # wildedit_pass1_nstd = 2.0 # wildedit_pass2_nstd = 5.0 # wildedit_pass2_mindelta = 0.000e+000 # wildedit_npoint = 50 # wildedit_vars = prDM # wildedit_excl_bad_scans = yes # alignctd_date = Mar 08 2004 14:11:40, 5.30a # alignctd_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\wildedit\2003-25-0026.c nv # alignctd_adv = c1S/m 0.073 # celltm_date = Mar 08 2004 14:13:15, 5.30a # celltm_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\align\2003-25-0026.cnv # celltm_alpha = 0.0200, 0.0300 # celltm_tau = 7.0000, 9.0000 # celltm_temp_sensor_use_for_cond = primary, secondary # Derive_date = Mar 08 2004 14:16:09, 5.30a # Derive_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\celltm\2003-25-0026.cnv Q :\Cruise_Data\2003-18\2003-18-CTD1.CON # file_type = ascii END* CTDEDIT was used to remove surface records to 4.2db and to clean salinity. -------------------------------------------------------------------- There were no salinity calibration samples for this cruise. The recalibration of salinity is based on the results of other cruises using the same equipment; the calibration sampling for those cruises was limited and there is evidence of drift in the calibration. There was a lot of fine-scale noise in the salinity channel. Salinity should be considered +/- 0.005psu. Transmissivity - The data are nominal and unedited. Fluorescence - The data are nominal and unedited. -------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.5E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.15E-02 1) $END !--1--- ---2---- --3-- ---4--- ---5---- -6-- !Pressu Temperat Trans Fluores Salinity Numb !re ure: missi cence: :T0:C0 er_o ! Primary vity URU: ~bin ! Seapoin _rec ! t ords !------ -------- ----- ------- -------- ---- *END OF HEADER 5.1 9.8882 26.2 0.027 31.8389 33 6.0 9.9348 26.4 0.030 31.8385 43 7.0 9.9983 26.0 0.031 31.8392 36 8.0 9.9550 25.9 0.036 31.8398 33 9.0 9.9283 25.8 0.053 31.8403 32 10.0 9.8130 25.8 0.124 31.8410 36 11.0 9.7849 26.4 0.867 31.8409 32 12.0 9.8193 26.3 2.053 31.8403 27 13.0 9.7900 26.7 2.595 31.8403 27 14.0 9.7621 27.1 2.761 31.8410 27 15.0 9.7373 27.7 3.055 31.8415 29 16.0 9.7392 27.8 3.129 31.8404 29 17.0 9.7509 28.1 3.016 31.8417 28 18.0 9.7154 28.3 3.411 31.8414 27 19.0 9.7287 28.3 3.318 31.8417 26 20.0 9.7118 28.5 3.264 31.8414 30 21.0 9.7101 28.6 3.136 31.8413 29 22.0 9.7094 28.8 2.862 31.8414 30 23.0 9.7097 28.8 2.899 31.8414 31 24.0 9.7096 28.7 2.885 31.8415 29 25.0 9.7096 28.7 3.184 31.8415 25 26.0 9.7098 28.8 3.514 31.8415 27 27.0 9.7090 28.8 3.912 31.8416 29 28.0 9.7082 28.6 3.053 31.8416 27 29.0 9.7081 28.5 3.065 31.8415 26 29.7 9.7083 28.6 3.247 31.8415 12