*2013/12/16 15:28:37.65 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/06/01 05:10:44.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 17 DATA DESCRIPTION : CTD FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 2.4 17.5 2 Temperature:Primary 'deg C (ITS90)' 10.1166 10.1709 3 Transmissivity %/metre 22.8 25.1 4 Fluorescence:URU:Seapoint mg/m^3 0.28E-01 1.875 5 Salinity:T0:C0 PSS-78 31.7983 31.7989 6 Number_of_bin_records n/a 2 47 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 9 F ' ' 4 6 ' ' ' ' 5 I I 0 $END $REMARKS This file converted from Sea-Bird file: Q:\Cruise_Data\2003-25\Hecate_Strait\ $END *ADMINISTRATION MISSION : 2003-25 AGENCY : PBS, Stock Assessment, Nanaimo, B.C. COUNTRY : Canada PROJECT : Hecate Strait Multi-Species Survey SCIENTIST : Workman G. PLATFORM : W.E. Ricker *LOCATION GEOGRAPHIC AREA : Hecate Strait STATION : F2 EVENT NUMBER : 16 LATITUDE : 53 35.09000 N ! (deg min) LONGITUDE : 131 23.41000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2424 pressure ' ' 69698 temperature:secondary ' ' 2374 conductivity:secondary ' ' 2399 Fluorometer ' ' Seapoint transmissometer:primary ' ' 197 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/03/08 14:58:46 3160 3160 CLEAN 4.5 2004/03/08 15:10:49 3156 3156 SHIFTDAT 3.3 2004/03/16 15:04:27 ? ? SHIFTDAT 3.3 2004/03/16 15:08:32 ? ? DELETE 6.3 2004/03/16 15:12:19 3156 669 CTDEDIT 4.50 2004/03/17 17:10:21 669 580 CALIB 11.4 2004/03/22 12:23:06 580 580 FILTERS 4.3 2004/03/22 12:59:01 580 580 BINAVE 4.0.1 2004/03/22 13:05:22 580 17 REMOVECH 6.0 2004/03/22 13:40:59 17 17 HDREDIT2 1.9 2004/03/22 14:15:43 ? ? HDREDIT2 1.9 2004/03/29 10:57:38 ? ? CALIB 11.4 2004/12/22 12:03:37 17 17 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:37 17 17 $END $REMARKS CLEAN functions: - Interpolation by Record Number, in Pressure -The following SHIFT parameters were used. Shift Channel: Conductivity:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= -1.10 Salinity was recalculated after shift -The following SHIFT parameters were used. Shift Channel: Fluorescence:URU:Seapoint # of Records to Advance (-ve for Delay): At REC# 0 Shift= 24.00 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 5.000 Surface Swell Pressure Tolerance: 1.00 Pressure filtered over width: 15 Swells deleted. Warning message if pressure difference of 2.00 Drop rates < 0.30m/s (calculated over 11 points) will be deleted. Drop rate applies in the range 10.00 to 7.93 dbars Sample interval (from FILE section of header) = 0.042 seconds. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-25\ctd\doc\2003-25-RECAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Salinity:T0:C0 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following FILTER parameters were used. Median filter was used. Filter width = 11 The following channel(s) were filtered. Fluorescence:URU:Seapoint -The following BINAVE parameters were used: Bin channel = Pressure Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Descent_Rate Status:Pump Salinity:T1:C1 Flag -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\RICKER recal\2003-25\2003-25-RECAL2.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.1500000E-02 0.1000000E+01 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\data\20030025\20030025016.dat Software Version Seasave Win32 V 5.27c Temperature SN = 2668 Conductivity SN = 2424 Number of Bytes Per Scan = 24 Number of Voltage Words = 2 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = Jun 01 2003 07:05:21 NMEA Latitude = 53 35.09 N NMEA Longitude = 131 23.41 W NMEA UTC (Time) = Jun 01 2003 05:10:44 Store Lat/Lon Data = Add to Header Only Ship: W.E Ricker WE RICKER Cruise: 2003-04 2003-25 Station: F2 Latitude: 53 35.10 Longitude: 131 23.41 Depth 21 # nquan = 13 # nvalues = 3160 # units = specified # name 0 = scan: Scan Count # name 1 = prDM: Pressure, Digiquartz [db] # name 2 = t090C: Temperature [ITS-90, deg C] # name 3 = t190C: Temperature, 2 [ITS-90, deg C] # name 4 = c0S/m: Conductivity [S/m] # name 5 = c1S/m: Conductivity, 2 [S/m] # name 6 = xmiss: Beam Transmission, Chelsea/Seatech/Wetlab CStar [%] # name 7 = flSP: Fluorescence, Seapoint # name 8 = dz/dtM: Descent Rate [m/s] # name 9 = pumps: Pump Status # name 10 = sal00: Salinity [PSU] # name 11 = sal11: Salinity, 2 [PSU] # name 12 = flag: flag # span 0 = 1, 3160 # span 1 = 0.329, 17.928 # span 2 = 9.6695, 10.1757 # span 3 = 9.6649, 10.2096 # span 4 = 0.077632, 3.509145 # span 5 = 0.056870, 3.511969 # span 6 = 0.2339, 70.9184 # span 7 = 0.0000e+00, 1.9121e+00 # span 8 = -0.829, 0.766 # span 9 = 0, 1 # span 10 = 0.5463, 31.7953 # span 11 = 0.3959, 31.8159 # span 12 = 0.0000e+00, 0.0000e+00 # interval = seconds: 0.0416667 # start_time = Jun 01 2003 07:05:21 # bad_flag = -9.990e-29 # sensor 0 = Frequency 0 temperature, primary, 2668, 20-Jun-02s # sensor 1 = Frequency 1 conductivity, primary, 2424, 16-Apr-02, cpcor = -9.57 00e-08 # sensor 2 = Frequency 2 pressure, 69698, 11-12-1997 # sensor 3 = Frequency 3 temperature, secondary, 2374, 20-Jun-02 # sensor 4 = Frequency 4 conductivity, secondary, 2399, 16-Apr-02, cpcor = -9. 5700e-08 # sensor 5 = Extrnl Volt 0 Fluorometer, Seapoint, primary # sensor 6 = Extrnl Volt 2 transmissometer, primary, 197, 22-Jan-03 # datcnv_date = Mar 08 2004 14:09:14, 5.30a # datcnv_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\2003-25-0016.dat Q:\Cruis e_Data\2003-25\Hecate_Strait\CTD\2003-25-ctd.con # datcnv_skipover = 0 # wildedit_date = Mar 08 2004 14:10:27, 5.30a # wildedit_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\convert\2003-25-0016.cn v # wildedit_pass1_nstd = 2.0 # wildedit_pass2_nstd = 5.0 # wildedit_pass2_mindelta = 0.000e+000 # wildedit_npoint = 50 # wildedit_vars = prDM # wildedit_excl_bad_scans = yes # alignctd_date = Mar 08 2004 14:11:32, 5.30a # alignctd_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\wildedit\2003-25-0016.c nv # alignctd_adv = c1S/m 0.073 # celltm_date = Mar 08 2004 14:13:07, 5.30a # celltm_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\align\2003-25-0016.cnv # celltm_alpha = 0.0200, 0.0300 # celltm_tau = 7.0000, 9.0000 # celltm_temp_sensor_use_for_cond = primary, secondary # Derive_date = Mar 08 2004 14:16:00, 5.30a # Derive_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\celltm\2003-25-0016.cnv Q :\Cruise_Data\2003-18\2003-18-CTD1.CON # file_type = ascii END* CTDEDIT was used to remove surface records to 2.4db and to clean salinity lightly. -------------------------------------------------------------------- There were no salinity calibration samples for this cruise. The recalibration of salinity is based on the results of other cruises using the same equipment; the calibration sampling for those cruises was limited and there is evidence of drift in the calibration. There was a lot of fine-scale noise in the salinity channel. Salinity should be considered +/- 0.005psu. Transmissivity - The data are nominal and unedited. Fluorescence - The data are nominal and unedited. -------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.5E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.15E-02 1) $END !--1--- ---2---- --3-- ---4--- ---5---- -6-- !Pressu Temperat Trans Fluores Salinity Numb !re ure: missi cence: :T0:C0 er_o ! Primary vity URU: ~bin ! Seapoin _rec ! t ords !------ -------- ----- ------- -------- ---- *END OF HEADER 2.4 10.1664 23.5 0.029 31.7984 13 3.0 10.1663 22.8 0.030 31.7985 45 4.0 10.1667 23.9 0.029 31.7985 40 5.0 10.1670 24.0 0.029 31.7986 47 6.0 10.1635 23.4 0.028 31.7987 39 7.0 10.1642 24.0 0.030 31.7988 32 8.0 10.1681 24.3 0.037 31.7988 33 9.0 10.1696 24.4 0.046 31.7987 41 9.9 10.1691 24.5 0.087 31.7987 42 11.0 10.1709 24.3 0.265 31.7988 32 12.0 10.1676 24.6 0.452 31.7987 36 13.0 10.1652 24.6 0.696 31.7988 37 14.0 10.1638 24.6 1.155 31.7988 35 15.0 10.1605 24.8 1.317 31.7988 35 16.0 10.1554 24.8 1.588 31.7986 34 17.0 10.1371 25.1 1.785 31.7983 37 17.5 10.1166 25.0 1.875 31.7989 2