*2013/12/16 15:28:37.45 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/05/31 09:56:56.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 21 DATA DESCRIPTION : CTD FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 5.1 25 2 Temperature:Primary 'deg C (ITS90)' 11.1991 11.2018 3 Transmissivity %/metre 26.7 27.7 4 Fluorescence:URU:Seapoint mg/m^3 0.3E-01 1.641 5 Salinity:T0:C0 PSS-78 31.9057 31.911 6 Number_of_bin_records n/a 26 62 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 8 F ' ' 3 5 -99 ' ' 9 F ' ' 4 6 ' ' ' ' 5 I I 0 $END $REMARKS This file converted from Sea-Bird file: Q:\Cruise_Data\2003-25\Hecate_Strait\ $END *ADMINISTRATION MISSION : 2003-25 AGENCY : PBS, Stock Assessment, Nanaimo, B.C. COUNTRY : Canada PROJECT : Hecate Strait Multi-Species Survey SCIENTIST : Workman G. PLATFORM : W.E. Ricker *LOCATION GEOGRAPHIC AREA : Hecate Strait STATION : C2 EVENT NUMBER : 9 LATITUDE : 54 4.91000 N ! (deg min) LONGITUDE : 131 23.07000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0506 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2668 conductivity:primary ' ' 2424 pressure ' ' 69698 temperature:secondary ' ' 2374 conductivity:secondary ' ' 2399 Fluorometer ' ' Seapoint transmissometer:primary ' ' 197 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/03/08 14:58:22 4158 4158 CLEAN 4.5 2004/03/08 15:10:17 4157 4157 SHIFTDAT 3.3 2004/03/16 15:03:57 ? ? SHIFTDAT 3.3 2004/03/16 15:08:02 ? ? DELETE 6.3 2004/03/16 15:11:56 4157 935 CTDEDIT 4.50 2004/03/17 15:51:45 935 730 CALIB 11.4 2004/03/22 12:22:59 730 730 FILTERS 4.3 2004/03/22 12:58:54 730 730 BINAVE 4.0.1 2004/03/22 13:05:18 730 21 REMOVECH 6.0 2004/03/22 13:40:59 21 21 HDREDIT2 1.9 2004/03/22 14:15:43 ? ? HDREDIT2 1.9 2004/03/29 10:57:13 ? ? CALIB 11.4 2004/12/22 12:03:36 21 21 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:37 21 21 $END $REMARKS CLEAN functions: - Interpolation by Record Number, in Pressure -The following SHIFT parameters were used. Shift Channel: Conductivity:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= -1.10 Salinity was recalculated after shift -The following SHIFT parameters were used. Shift Channel: Fluorescence:URU:Seapoint # of Records to Advance (-ve for Delay): At REC# 0 Shift= 24.00 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 5.000 Surface Swell Pressure Tolerance: 1.00 Pressure filtered over width: 15 Swells deleted. Warning message if pressure difference of 2.00 Drop rates < 0.30m/s (calculated over 11 points) will be deleted. Drop rate applies in the range 10.00 to 15.59 dbars Sample interval (from FILE section of header) = 0.042 seconds. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-25\ctd\doc\2003-25-RECAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Salinity:T0:C0 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following FILTER parameters were used. Median filter was used. Filter width = 11 The following channel(s) were filtered. Fluorescence:URU:Seapoint -The following BINAVE parameters were used: Bin channel = Pressure Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Descent_Rate Status:Pump Salinity:T1:C1 Flag -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\RICKER recal\2003-25\2003-25-RECAL2.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.1500000E-02 0.1000000E+01 $END *COMMENTS SBE HEADER Sea-Bird SBE 9 Data File: FileName = C:\data\20030025\20030025009.dat Software Version Seasave Win32 V 5.27c Temperature SN = 2668 Conductivity SN = 2424 Number of Bytes Per Scan = 24 Number of Voltage Words = 2 Number of Scans Averaged by the Deck Unit = 1 System UpLoad Time = May 31 2003 11:51:37 NMEA Latitude = 54 04.91 N NMEA Longitude = 131 23.07 W NMEA UTC (Time) = May 31 2003 09:56:56 Store Lat/Lon Data = Add to Header Only Ship: W.E Ricker WE RICKER Cruise: 2003-04 2003-25 Station: C2 Latitude: 54 04.9 Longitude: 131 23. Depth # nquan = 13 # nvalues = 4158 # units = specified # name 0 = scan: Scan Count # name 1 = prDM: Pressure, Digiquartz [db] # name 2 = t090C: Temperature [ITS-90, deg C] # name 3 = t190C: Temperature, 2 [ITS-90, deg C] # name 4 = c0S/m: Conductivity [S/m] # name 5 = c1S/m: Conductivity, 2 [S/m] # name 6 = xmiss: Beam Transmission, Chelsea/Seatech/Wetlab CStar [%] # name 7 = flSP: Fluorescence, Seapoint # name 8 = dz/dtM: Descent Rate [m/s] # name 9 = pumps: Pump Status # name 10 = sal00: Salinity [PSU] # name 11 = sal11: Salinity, 2 [PSU] # name 12 = flag: flag # span 0 = 1, 4158 # span 1 = 0.556, 25.587 # span 2 = 10.4650, 11.2416 # span 3 = 10.3970, 11.2273 # span 4 = 0.107585, 3.613549 # span 5 = 0.038688, 3.611064 # span 6 = 0.0810, 72.8040 # span 7 = 0.0000e+00, 2.6593e+00 # span 8 = -1.003, 0.950 # span 9 = 0, 1 # span 10 = 0.7517, 31.9077 # span 11 = 0.2603, 31.9029 # span 12 = 0.0000e+00, 0.0000e+00 # interval = seconds: 0.0416667 # start_time = May 31 2003 11:51:37 # bad_flag = -9.990e-29 # sensor 0 = Frequency 0 temperature, primary, 2668, 20-Jun-02s # sensor 1 = Frequency 1 conductivity, primary, 2424, 16-Apr-02, cpcor = -9.57 00e-08 # sensor 2 = Frequency 2 pressure, 69698, 11-12-1997 # sensor 3 = Frequency 3 temperature, secondary, 2374, 20-Jun-02 # sensor 4 = Frequency 4 conductivity, secondary, 2399, 16-Apr-02, cpcor = -9. 5700e-08 # sensor 5 = Extrnl Volt 0 Fluorometer, Seapoint, primary # sensor 6 = Extrnl Volt 2 transmissometer, primary, 197, 22-Jan-03 # datcnv_date = Mar 08 2004 14:09:09, 5.30a # datcnv_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\2003-25-0009.dat Q:\Cruis e_Data\2003-25\Hecate_Strait\CTD\2003-25-ctd.con # datcnv_skipover = 0 # wildedit_date = Mar 08 2004 14:10:21, 5.30a # wildedit_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\convert\2003-25-0009.cn v # wildedit_pass1_nstd = 2.0 # wildedit_pass2_nstd = 5.0 # wildedit_pass2_mindelta = 0.000e+000 # wildedit_npoint = 50 # wildedit_vars = prDM # wildedit_excl_bad_scans = yes # alignctd_date = Mar 08 2004 14:11:25, 5.30a # alignctd_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\wildedit\2003-25-0009.c nv # alignctd_adv = c1S/m 0.073 # celltm_date = Mar 08 2004 14:13:00, 5.30a # celltm_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\align\2003-25-0009.cnv # celltm_alpha = 0.0200, 0.0300 # celltm_tau = 7.0000, 9.0000 # celltm_temp_sensor_use_for_cond = primary, secondary # Derive_date = Mar 08 2004 14:15:53, 5.30a # Derive_in = Q:\Cruise_Data\2003-25\Hecate_Strait\CTD\celltm\2003-25-0009.cnv Q :\Cruise_Data\2003-18\2003-18-CTD1.CON # file_type = ascii END* CTDEDIT was used to remove surface records to 4.7db; salinity was cleaned very lightly. -------------------------------------------------------------------- There were no salinity calibration samples for this cruise. The recalibration of salinity is based on the results of other cruises using the same equipment; the calibration sampling for those cruises was limited and there is evidence of drift in the calibration. There was a lot of fine-scale noise in the salinity channel. Salinity should be considered +/- 0.005psu. Transmissivity - The data are nominal and unedited. Fluorescence - The data are nominal and unedited. -------------------------------------------------------------------- *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (0.5E-02 1) Salinity:T0:C0 PSS-78 10 -99 () (0.15E-02 1) $END !--1--- ---2---- --3-- ---4--- ---5---- -6-- !Pressu Temperat Trans Fluores Salinity Numb !re ure: missi cence: :T0:C0 er_o ! Primary vity URU: ~bin ! Seapoin _rec ! t ords !------ -------- ----- ------- -------- ---- *END OF HEADER 5.1 11.1991 26.7 0.035 31.9058 26 6.0 11.1994 26.8 0.030 31.9058 35 7.0 11.1991 27.0 0.033 31.9062 45 8.0 11.1996 27.0 0.035 31.9067 39 9.0 11.1996 27.0 0.041 31.9076 36 10.0 11.1996 27.2 0.047 31.9069 35 11.0 11.1991 26.9 0.061 31.9057 29 12.0 11.1997 27.2 0.071 31.9071 29 13.0 11.1999 27.2 0.111 31.9073 29 14.0 11.2003 27.2 0.184 31.9085 26 15.0 11.2007 27.2 0.279 31.9087 34 15.9 11.2010 27.4 0.443 31.9093 47 17.0 11.2012 27.4 0.619 31.9097 28 18.0 11.2015 27.3 0.786 31.9096 28 19.0 11.2014 27.6 0.937 31.9096 35 20.0 11.2016 27.6 1.012 31.9094 35 21.0 11.2016 27.5 1.126 31.9091 29 22.0 11.2016 27.7 1.213 31.9093 29 23.0 11.2014 27.4 1.314 31.9108 35 24.0 11.2018 27.5 1.284 31.9106 39 25.0 11.2014 27.5 1.641 31.9110 62