*2014/11/20 09:53:52.83 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/07/18 18:13:02.000 TIME INCREMENT : 0 0 0 0.125 0 ! (day hr min sec ms) NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 10 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 267 278 2 Pressure decibar 1.625 44.182 3 Temperature:Primary 'deg C (ITS90)' 2.748 4.1701 4 Transmissivity %/metre 1.4 45.2 5 Fluorescence:URU:Seapoint mg/m^3 1.443 4.831 6 Salinity:T0:C0 PSS-78 32.4937 32.7551 7 Bottle_Number n/a 1 12 8 Number_of_bin_records n/a 21 41 9 Salinity:Bottle PSS-78 32.6842 32.6842 10 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 3 I I 0 8 -99 ' ' 5 I I 0 9 -9.9 ' ' 9 F R4 4 10 -99 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2003-18 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : Bering Strait SCIENTIST : Eert J. PLATFORM : Sir Wilfrid Laurier *LOCATION GEOGRAPHIC AREA : Bering Sea/Bering Strait/Chukchi Sea STATION : UTN-5 EVENT NUMBER : 27 LATITUDE : 67 40.23000 N ! (deg min) LONGITUDE : 168 52.45000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 0293 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature ' ' 034115 conductivity ' ' 042607 Pressure ' ' 290464 Oxygen:SBE ' ' 430052 userpoly ' ' ' ' Fluorometer ' ' Seapoint transmissometer:primary ' ' #139 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.28E $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/02/26 14:40:53 468 468 ADDSAMP 3.4 2004/02/28 14:21:20 468 468 BINAVE 4.0.1 2004/02/28 14:27:23 468 12 SORT 3.4.1 2004/02/28 14:29:05 12 12 MERGE 3.1 2004/02/28 14:48:38 12 12 CLEAN 4.6.2 2004/06/09 08:41:52 ? ? SORT 3.4.1 2004/06/09 08:42:06 12 12 REMOVECH 6.0 2004/06/09 08:44:42 12 12 HDREDIT2 2.2 2004/06/09 08:45:26 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:29:19 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:22 12 12 CHANGE_FLAGS 2.0 2014/11/20 09:53:52 12 12 $END $REMARKS -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2003-18\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following SORT parameters were used. Sorted by channel: Sample_Number Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2003-18\hydro\2003-18-0027.samsort Secondary file: Q:\Cruise_Data\2003-18\hydro\2003-18-0027.sal1 CLEAN functions: - Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure:StrainGauge Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Scan_Number Conductivity:Primary Oxygen:Dissolved:SBE Descent_Rate uploy0 Flag Header Edits: - applied edit header: Q:\Cruise_Data\2003-18\doc\2003-18-hdr3.txt - Chan 1: Sample_Number [n/a] Pad: -9 ==> -99 - Chan 2: Pressure:StrainGauge [dbars] Name ==> Pressure Format: F10.3 ==> F7.1 - Chan 3: Temperature:Primary [deg C (ITS90)] (no changes) - Chan 4: Transmissivity [%/metre] (no changes) - Chan 5: Fluorescence:URU:Seapoint [mg/m^3] (no changes) - Chan 6: Salinity:T0:C0 [PSS-78] (no changes) - Chan 7: Bottle_Number [n/a] (no changes) - Chan 8: Number_of_bin_records [n/a] Format: F5.0 ==> I5 Pad: ' ' ==> -99 - Chan 9: Salinity:Bottle [PSS-78] (no changes) - Chan 10: Flag:Salinity:Bottle [] Pad: 0 ==> -99 $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Nutrient samples are analyzed frozen using a Technicon AAII autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *************************************************************** Fluorescence:URU:Seapoint – The data are nominal and unedited and frequently off-scale. There was no chlorophyll sampling. Transmissivity: The data are nominal and unedited. The pressure sensor is considered ±1db. The dissolved oxygen data was removed because the errors are believed to be large and there was no calibration sampling. *************************************************************** !-1-- --2--- ---3---- --4-- ---5--- ---6---- 7- -8-- ---9---- - !Samp Pressu Temperat Trans Fluores Salinity Bo Numb Salinity F !le_ re ure: missi cence: :T0:C0 tt er_o :Bottle l !Numb Primary vity URU: ~u ~bin ~ !er Seapoin mb _rec l ! t er ords e !---- ------ -------- ----- ------- -------- -- ---- -------- - *END OF HEADER 278 1.6 4.1701 44.9 1.443 32.5093 12 40 -9.9000 0 277 5.7 4.1665 45.2 1.938 32.5091 11 39 -9.9000 0 276 10.8 4.1482 45.2 2.138 32.5066 10 40 -9.9000 0 275 15.1 3.8438 40.4 4.207 32.4937 9 41 -9.9000 0 274 20.5 3.8865 33.6 4.831 32.5124 8 41 -9.9000 0 272 25.2 3.1204 36.7 4.531 32.6427 6 39 -9.9000 0 273 25.2 3.1158 37.1 3.983 32.6436 7 40 -9.9000 0 271 30.2 2.7661 39.0 2.757 32.6741 5 37 -9.9000 0 270 34.5 2.7480 25.2 3.289 32.6837 4 40 32.6842 0 269 40.1 2.8407 9.1 3.376 32.7041 3 40 -9.9000 0 267 44.2 3.0119 1.4 4.419 32.7551 1 21 -9.9000 0 268 44.2 3.0121 1.4 3.760 32.7550 2 29 -9.9000 0