*2014/11/20 09:53:52.13 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/07/13 23:03:08.000 TIME INCREMENT : 0 0 0 0.125 0 ! (day hr min sec ms) NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 10 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 37 48 2 Pressure decibar 1.414 104.707 3 Temperature:Primary 'deg C (ITS90)' 3.9091 9.2219 4 Transmissivity %/metre 29.5 56.3 5 Fluorescence:URU:Seapoint mg/m^3 0.151 4.826 6 Salinity:T0:C0 PSS-78 32.3079 32.6768 7 Bottle_Number n/a 1 12 8 Number_of_bin_records n/a 36 41 9 Salinity:Bottle PSS-78 32.6816 32.6816 10 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 3 I I 0 8 -99 ' ' 5 I I 0 9 -9.9 ' ' 9 F R4 4 10 -99 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2003-18 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : Bering Strait SCIENTIST : Eert J. PLATFORM : Sir Wilfrid Laurier *LOCATION GEOGRAPHIC AREA : Bering Sea/Bering Strait/Chukchi Sea STATION : BS-6 EVENT NUMBER : 6 LATITUDE : 59 19.06000 N ! (deg min) LONGITUDE : 173 29.93000 W ! (deg min) WATER DEPTH : 110 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-25 SERIAL NUMBER : 0293 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature ' ' 034115 conductivity ' ' 042607 Pressure ' ' 290464 Oxygen:SBE ' ' 430052 Fluorometer ' ' Seapoint transmissometer:primary ' ' #139 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.28C $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/02/26 14:40:47 492 492 ADDSAMP 3.4 2004/02/28 14:21:12 492 492 BINAVE 4.0.1 2004/02/28 14:27:18 492 12 SORT 3.4.1 2004/02/28 14:29:04 12 12 MERGE 3.1 2004/02/28 14:48:37 12 12 CLEAN 4.6.2 2004/06/09 08:41:51 ? ? SORT 3.4.1 2004/06/09 08:42:05 12 12 REMOVECH 6.0 2004/06/09 08:44:25 12 12 HDREDIT2 2.2 2004/06/09 08:45:24 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:29:19 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:28:22 12 12 CHANGE_FLAGS 2.0 2014/11/20 09:53:52 12 12 $END $REMARKS -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_Data\2003-18\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following SORT parameters were used. Sorted by channel: Sample_Number Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2003-18\hydro\2003-18-0006.samsort Secondary file: Q:\Cruise_Data\2003-18\hydro\2003-18-0006.sal1 CLEAN functions: - Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure:StrainGauge Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Scan_Number Conductivity:Primary Oxygen:Dissolved:SBE Descent_Rate Flag Header Edits: - applied edit header: Q:\Cruise_Data\2003-18\doc\2003-18-hdr3.txt - Chan 1: Sample_Number [n/a] Pad: -9 ==> -99 - Chan 2: Pressure:StrainGauge [dbars] Name ==> Pressure Format: F10.3 ==> F7.1 - Chan 3: Temperature:Primary [deg C (ITS90)] (no changes) - Chan 4: Transmissivity [%/metre] (no changes) - Chan 5: Fluorescence:URU:Seapoint [mg/m^3] (no changes) - Chan 6: Salinity:T0:C0 [PSS-78] (no changes) - Chan 7: Bottle_Number [n/a] (no changes) - Chan 8: Number_of_bin_records [n/a] Format: F5.0 ==> I5 Pad: ' ' ==> -99 - Chan 9: Salinity:Bottle [PSS-78] (no changes) - Chan 10: Flag:Salinity:Bottle [] Pad: 0 ==> -99 $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Nutrient samples are analyzed frozen using a Technicon AAII autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *************************************************************** Fluorescence:URU:Seapoint – The data are nominal and unedited and frequently off-scale. There was no chlorophyll sampling. Transmissivity: The data are nominal and unedited. The pressure sensor is considered ±1db. The dissolved oxygen data was removed because the errors are believed to be large and there was no calibration sampling. *************************************************************** !-1-- --2--- ---3---- --4-- ---5--- ---6---- 7- -8-- ---9---- - !Samp Pressu Temperat Trans Fluores Salinity Bo Numb Salinity F !le_ re ure: missi cence: :T0:C0 tt er_o :Bottle l !Numb Primary vity URU: ~u ~bin ~ !er Seapoin mb _rec l ! t er ords e !---- ------ -------- ----- ------- -------- -- ---- -------- - *END OF HEADER 48 1.4 8.7712 41.4 1.326 32.3107 12 40 -9.9000 0 47 5.4 9.2219 40.6 1.679 32.3079 11 41 -9.9000 0 46 11.2 8.5281 40.2 4.369 32.3124 10 36 -9.9000 0 45 16.2 8.4862 40.6 4.826 32.3368 9 41 -9.9000 0 44 20.9 8.4868 45.3 4.767 32.3692 8 41 -9.9000 0 43 25.8 7.0429 45.9 4.823 32.4016 7 37 -9.9000 0 42 30.3 5.5332 49.8 4.123 32.4874 6 39 -9.9000 0 41 40.7 4.4872 54.6 1.489 32.6014 5 41 -9.9000 0 40 50.6 3.9228 56.3 0.248 32.6047 4 40 -9.9000 0 39 60.6 3.9091 47.9 0.151 32.6717 3 39 -9.9000 0 38 70.9 3.9149 45.0 0.180 32.6766 2 41 -9.9000 0 37 104.7 3.9480 29.5 0.241 32.6768 1 39 32.6816 0