*2013/12/16 15:27:37.29 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2003/05/30 14:59:25.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 23 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 19 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 78 100 2 Pressure decibar 2.3 3271.9 3 Temperature:Primary 'deg C (ITS90)' 1.6524 10.7898 4 Transmissivity %/metre 45.2 61 5 Fluorescence:URU:Seapoint mg/m^3 0.124 2.255 6 Oxygen:Dissolved:SBE mL/L 0.2842 6.7228 7 Bottle_Number n/a 1 23 8 Salinity:T0:C0 PSS-78 32.2083 34.6473 9 Number_of_bin_records n/a 119 121 10 Salinity:Bottle PSS-78 32.21 34.6489 11 Flag:Salinity:Bottle n/a 12 Nitrate_plus_Nitrite umol/L 3.1 45 13 Flag:Nitrate_plus_Nitrite n/a 14 Silicate umol/L 5.7 177.5 15 Flag:Silicate n/a 16 Phosphate umol/L 0.71 3.23 17 Flag:Phosphate n/a 18 Oxygen:Dissolved mL/L 0.46 6.667 19 Flag:Oxygen:Dissolved newunits $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -9 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 3 I I 0 8 -99 ' ' 9 F ' ' 4 9 ' ' ' ' 5 I I 0 10 -99 ' ' 9 F R4 4 11 0 ' ' 2 NQ C ' ' 12 -99 ' ' ' ' F6.1 R4 ' ' 13 0 ' ' 2 NQ C ' ' 14 -99 ' ' ' ' F6.1 R4 ' ' 15 0 ' ' 2 NQ C ' ' 16 -99 ' ' ' ' F7.2 R4 ' ' 17 0 ' ' 2 NQ C ' ' 18 -99 ' ' 8 F ' ' 3 19 0 ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- Comments from secondary file: H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.clnadd ---------------------------------------------------------- Raw data in file oxydata\2003-11-\2003-11-0018.o2 VIO3 = 10.02 ! Volume of iodate standard (cm**) NIO3 = .01013204 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) $END *ADMINISTRATION MISSION : 2003-11 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : N.E.Pacific STATION : P12 EVENT NUMBER : 18 LATITUDE : 48 58.24000 N ! (deg min) LONGITUDE : 130 39.99000 W ! (deg min) WATER DEPTH : 3225 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2095 conductivity:primary ' ' 2102 pressure ' ' 75636 temperature:secondary ' ' 2710 conductivity:secondary ' ' 2278 Fluorometer ' ' Seapoint transmissometer:primary ' ' 333DR Oxygen:SBE ' ' 0047 $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.27C Comments from secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.add --------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. Comments from secondary file: H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.clnadd ---------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.5 2003/08/14 13:53:20 2783 2783 ADDSAMP 3.4 2003/08/21 09:15:51 2783 2783 BINAVE 4.0.1 2003/08/21 09:17:00 2783 23 MERGE 3.0 2003/08/31 13:10:07 23 23 MERGE 3.0 2003/08/31 13:13:24 23 23 MERGE 3.0 2003/08/31 13:14:31 23 23 CALIB 11.2 2003/09/22 08:37:26 23 23 CLEAN 4.4 2003/09/22 11:05:06 ? ? REMOVECH 6.0 2003/09/22 11:10:59 23 23 HDREDIT2 1.7 2003/09/22 12:07:21 ? ? MERGE 3.1 2003/10/06 16:22:14 23 23 HDREDIT2 1.8 2003/10/08 13:52:42 ? ? REVERSE 2.0 2004/01/02 16:48:17 23 23 SORT 3.4.1 2004/04/23 11:53:40 23 23 REMOVECH 7.0 2005/09/19 14:41:42 23 23 SORT 3.5 2005/09/19 14:42:08 23 23 MERGE 3.3 2005/09/19 15:55:02 23 23 SORT 3.5 2005/09/19 16:07:28 23 23 CALIB 11.5 2005/10/07 10:41:11 23 23 CHANGE_FLAGS 1.0 2013/07/16 11:47:16 23 23 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:27:37 23 23 $END $REMARKS -The following ADDSAMP parameters were used: Sample Number Lookup File: Q:\Cruise_data\2003-11\hydro\addsamp.csv Bottle Channel Name: Bottle_Number -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\2003-11\hydro\2003-11-0018.samavg Secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.sal -MERGE *** Secondary file not found *** Primary file : Q:\Cruise_Data\2003-11\hydro\2003-11-0018.mrg1 Secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.chl -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : Q:\Cruise_Data\2003-11\hydro\2003-11-0018.mrg2 Secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.add Comments from secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.add --------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-11\doc\2003-11-0550-rcal2.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Oxygen:Dissolved:SBE mL/L 10 -0.3740000E-01 0.1138600E+01 CLEAN functions: - Remove Sea-Bird comments from the header. -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Oxygen:Voltage:SBE Descent_Rate Salinity:T1:C1 Flag -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate Primary file : H:\Cruise_Data\2003-11\nuts\2003-11-0018.che Secondary file: H:\Cruise_Data\2003-11\nuts\2003-11-0018.rev -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -REMOVECH 2005/09/19 14:41:42 The following CHANNEL(S) were removed: Oxygen:Dissolved [mL/L] Flag:Oxygen:Dissolved -SORT parameters: 2005/09/19 14:42:08 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2005/09/19 15:55:02 2005/09/19 15:55:02 2005/09/19 15:55: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.srtrem Secondary file: H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.clnadd Comments from secondary file: H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.clnadd ---------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.005 Sodium Thiosulfate concentration = 0.729 Volume of iodate standard (cm**3) = 10.02 Enter Normalitity of iodate standard = 0.01013000 -CLEAN functions: 2005/09/19 15:49:21 20 Reset #RECS, MIN & MAX values in header. Change Pad Value to -99 in All Channels. -SORT parameters: 2005/09/19 16:07:28 Sorted in ascending order of channel Pressure -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\Cruise_Data\2003-11\2003-11-recal4.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 6 Oxygen:Dissolved:SBE mL/L 10 0.0000000E+00 0.9800000E+00 $END *COMMENTS Comments from secondary file: Q:\Cruise_Data\2003-11\hydro\2003-11-0018.sal --------------------------------------------- Sample # 78 - unstable Sample # 80 - cap a little off Sample # 81 - cap a little off Sample # 82 - cap a little off Sample # 85 - cap a little off Sample # 86 - cap a little off Sample # 93 - unstable Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. Comments from secondary file: H:\Data Processing\Oxygen redo\2003-11\2003-11-0018.clnadd ---------------------------------------------------------- This cast was run through the DOXX program for calculating dissolved oxygen values. The standard values defaulted to an incorrect number; should be 0.729. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------------- ------ ---- ------ ------------ Oxygen:Dissolved:SBE mL/L 10 -99 () (-0.374E-01 1.1386) Oxygen:Dissolved:SBE mL/L 10 -99 () (0 0.98) $END !-1-- --2--- ---3---- --4-- ---5--- --6--- 7- ---8---- -9-- ---10--- - --12- - --14- - --16-- - ---18-- - !Samp Pressu Temperat Trans Fluores Oxygen Bo Salinity Numb Salinity F Nitra F Silic F Phosph F Oxygen: F !le_ re ure: missi cence: : tt :T0:C0 er_o :Bottle l te_ l ate l ate l Dissolv l !Numb Primary vity URU: Dissol ~u ~bin ~ plus_ ~ ~ ~ ed ~ !er Seapoin ved: mb _rec l Nitri t t t e ! t SBE er ords e te e e e d !---- ------ -------- ----- ------- ------ -- -------- ---- -------- - ----- - ----- - ------ - ------- - *END OF HEADER 100 2.3 10.7605 45.2 1.199 6.70 23 32.2116 121 32.2136 3.1 5.7 0.71 6.667 99 9.8 10.7898 46.6 1.244 6.69 22 32.2112 121 32.2138 3.1 5.7 0.71 6.607 98 25.5 10.4849 47.0 2.255 6.72 21 32.2083 121 32.2100 3.3 5.9 0.73 6.595 97 48.8 8.7253 56.0 1.003 6.60 20 32.3084 120 32.3093 6.9 7.3 0.93 6.574 96 74.2 7.5465 59.4 0.283 5.88 19 32.6082 121 32.6033 14.2 15.0 1.33 5.893 95 100.1 7.0190 59.1 0.147 4.43 18 33.1064 121 33.0952 22.9 31.0 1.83 4.427 94 124.9 6.8415 59.7 0.126 4.19 17 33.4635 121 33.4411 24.7 32.2 1.89 4.219 93 149.0 7.0293 59.8 0.124 3.47 16 33.6689 121 33.6662 4 27.5 37.2 2.05 3.531 92 174.8 7.1229 59.8 0.126 2.79 15 33.8327 121 33.8277 30.0 42.2 2.20 2.830 91 191.5 6.9892 59.8 0.127 2.69 14 33.8632 121 33.8658 30.9 44.8 2.25 2.699 90 247.3 6.5523 60.1 0.126 1.97 13 33.9603 120 33.9620 34.4 54.7 2.50 1.973 89 301.5 6.1601 60.2 0.125 1.61 12 33.9888 121 33.9895 36.6 60.2 2.65 1.618 88 399.6 5.3704 60.6 0.128 1.11 11 34.0319 121 34.0340 39.7 74.6 2.89 1.110 87 598.5 4.4835 60.9 0.130 0.46 10 34.1501 121 34.1520 43.3 98.1 3.14 0.460 86 798.4 3.9321 60.8 0.131 0.28 9 34.2693 121 34.2684 4 44.0 116.3 3.23 0.623 85 1000.3 3.2312 60.9 0.131 0.29 8 34.3398 121 34.3404 4 45.0 136.8 3.23 0.640 84 1252.9 2.8717 60.9 0.132 0.39 7 34.4408 119 34.4416 44.6 148.9 3.23 0.561 83 1498.0 2.4469 61.0 0.131 0.61 6 34.4944 120 34.4960 44.5 161.6 3.17 0.584 82 1498.5 2.4469 61.0 0.130 0.61 5 34.4944 121 34.4959 4 44.4 161.1 3.17 0.566 81 1999.0 1.9577 61.0 0.127 1.38 4 34.5850 121 34.5866 4 42.6 175.2 3.02 1.336 80 2500.5 1.7581 60.8 0.124 1.89 3 34.6241 121 34.6260 4 41.2 177.1 2.92 1.865 79 2999.2 1.6524 60.7 0.125 2.28 2 34.6460 121 34.6455 40.2 177.3 2.84 2.274 78 3271.9 1.6699 60.7 0.125 2.32 1 34.6473 121 34.6489 4 39.9 177.5 2.83 2.282