*2014/11/20 09:53:23.03 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2002/05/02 13:24:10.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 11 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------------- --------------- -------------- -------------- 1 Sample_Number n/a 104 112 2 Pressure decibar 2 100.3 3 Temperature:Primary 'deg C (ITS90)' 7.194 8.928 4 Transmissivity %/metre 16.4 60.9 5 PAR uE/m^2/sec 0.8 20 6 PAR:Reference uE/m^2/sec 46.6 74.9 7 Salinity:T0:C0 PSS-78 31.8908 33.6974 8 Bottle_Number n/a 1 9 9 Salinity:Bottle PSS-78 34.1031 34.1031 10 Flag:Salinity:Bottle n/a 11 Chlorophyll:Extracted mg/m^3 0.17 5.4 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 7 F ' ' 1 6 -99 ' ' 7 F ' ' 1 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 3 I I 0 9 -99 ' ' ' ' f9.4 R4 ' ' 10 -99 ' ' 2 NQ C ' ' 11 -99 ' ' ' ' f7.2 R4 ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2002-14 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : WCVI Plankton SCIENTIST : Mackas D. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WCVI/QCI STATION : BI01 EVENT NUMBER : 33 LATITUDE : 48 31.44000 N ! (deg min) LONGITUDE : 126 10.88000 W ! (deg min) WATER DEPTH : 319 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------- -------------- ---------- temperature:primary ' ' 2038 conductivity:primary ' ' 1729 pressure ' ' 77511 temperature:secondary ' ' 2968 conductivity:secondary ' ' 2173 Fluorometer ' ' Seapoint transmissometer:primary ' ' 498DR Oxygen:SBE ' ' 0047 irradiance ' ' 4601 surface ' ' 'degrees = 0.0' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.25A $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.2 2002/08/07 13:31:35 1070 1070 BINAVE 4.0.1 2002/08/09 14:23:25 1070 9 CALIB 10.3 2002/08/20 16:40:24 9 9 REMOVECH 6.0 2002/08/20 16:44:15 9 9 REORDER 1.2 2002/08/20 16:48:35 ? ? HDREDIT2 1.5 2002/08/20 16:49:45 ? ? SORT 3.4 2002/10/04 10:20:05 9 9 MERGE 2.8 2002/10/04 10:29:26 9 9 SORT 3.4 2002/10/04 10:31:04 9 9 MERGE 2.8 2002/10/04 11:11:43 9 9 MERGE 2.8 2002/10/04 12:11:06 8 8 CLEAN 3.9 2002/10/04 12:26:47 8 8 ADDCHANS 1.0 2002/10/28 08:56:37 ? ? MERGE 2.8 2002/10/28 14:57:48 8 8 HDREDIT2 1.51 2003/01/10 14:56:13 ? ? CLEAN 4.0 2003/01/10 14:57:33 8 8 SORT 3.4.1 2004/04/14 16:28:41 8 8 HDREDIT2 2.0 2004/04/28 11:31:18 ? ? HDREDIT2 2.1 2004/05/26 08:59:26 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:28:51 8 8 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:25:55 8 8 CHANGE_FLAGS 2.0 2014/11/20 09:53:23 8 8 $END $REMARKS -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.0 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\CTD\2002-14\SPAR.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 11 Irradiance (PAR:Surface n/a 10 0.0000000E+00 0.1000160E+01 -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Chlorophyll:Fluorescence:Seapoint Oxygen:Dissolved:SBE Salinity:T1:C1 Flag -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Temperature:Primary, Transmissivity, PAR, PAR:Reference, Salinity:T0:C0 Secondary Channels to Include: Bottle_Number, Sample_Number Primary file : D:\Data\2002\2002-14\2002-14-0033.rev Secondary file: D:\Data\2002\2002-14\2002-14-0033.tab Comments from secondary file: D:\Data\2002\2002-14\2002-14-0033.tab ------------------------------------------------------------------- -The following SORT parameters were used. Sorted by channel: Sample_Number Pressure channel sorted according to values in sort channel -The following SORT parameters were used. Sorted by channel: Bottle_Number Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, PAR, PAR:Reference, Salinity:T0:C0, Bottle_Number Secondary Channels to Include: Oxygen:Dissolved Primary file : D:\Data\2002\2002-14\2002-14-0033.hyd Secondary file: D:\Data\2002\2002-14\2002-14-0033.dox -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, PAR, PAR:Reference, Salinity:T0:C0, Bottle_Number, Oxygen:Dissolved Secondary Channels to Include: Salinity:Bottle Primary file : D:\Data\2002\2002-14\2002-14-0033.mrg Secondary file: D:\Data\2002\2002-14\2002-14-0033.sal CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Remove Sea-Bird comments from the header. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, PAR, PAR:Reference, Salinity:T0:C0, Bottle_Number, Oxygen:Dissolved, Flag:Oxygen:Dissolved, Salinity:Bottle, Flag:Salinity:Bottle Secondary Channels to Include: Chlorophyll Primary file : D:\Data\2002\2002-14\2002-14-0033.add Secondary file: D:\Data\2002\2002-14\2002-14-0033.nut CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1966). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences utrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------------------- ----- ---- ------ ------------ 'Irradiance (PAR:Surface' n/a 10 -9.9 () (0 1.00016) $END !-1-- --2--- ---3---- --4--- --5--- --6--- ---7---- 8- ---9---- - --11-- !Samp Pressu Temperat Transm PAR PAR: Salinity Bo Salinity F Chloro !le_ re ure: issivi Refere :T0:C0 tt :Bottle l phyll: !Numb Primary ty nce ~u ~ Extrac !er mb l ted ! er e !---- ------ -------- ------ ------ ------ -------- -- -------- - ------ *END OF HEADER 112 2.0 8.8366 16.4 20.0 74.9 31.8965 9 -99.0000 0 5.32 111 4.0 8.9280 17.1 7.7 68.9 31.8908 8 -99.0000 0 5.40 109 9.7 8.5218 32.1 2.1 64.7 31.9247 6 -99.0000 0 4.57 108 25.0 7.7131 50.3 1.0 59.7 32.1223 5 -99.0000 0 0.98 107 45.0 7.1940 57.2 0.9 50.6 32.4052 4 -99.0000 0 -99.00 106 45.6 7.1964 57.1 0.9 50.6 32.4076 3 -99.0000 0 0.38 105 65.3 7.3543 58.5 0.8 48.6 32.6744 2 -99.0000 0 0.17 104 100.3 7.3340 60.9 0.8 46.6 33.6974 1 34.1031 0 -99.00