*2003/01/06 15:58:57.09 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 2002/01/11 03:23:05.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 11 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 11 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 92 102 2 Pressure dbars 1.4 119.1 3 Temperature:Primary 'deg C (ITS90)' 8.2014 8.2509 4 Transmissivity %/metre 31 43.4 5 Fluorescence:URU:Seapoint mg/m^3 0.186 0.351 6 Bottle_Number n/a 1 11 7 Salinity:T0:C0 PSS-78 30.6629 31.121 8 Oxygen:Dissolved mL/L 5.276 5.816 9 Flag:Oxygen:Dissolved ' ' 10 Salinity:Bottle PSS-78 31.1228 31.131 11 Flag:Salinity:Bottle ' ' $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ------ ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -9.9 ' ' 7 F ' ' 1 3 -9.9 ' ' 9 F ' ' 4 4 -9.9 ' ' 7 F ' ' 1 5 -9.9 ' ' 8 F ' ' 3 6 -9.9 ' ' 3 I I 0 7 -9.9 ' ' 9 F ' ' 4 8 -99.99 ' ' 8 F ' ' 3 9 ' ' ' ' 2 NQ C ' ' 10 -9.9 ' ' ' ' f9.4 R4 ' ' 11 ' ' ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ---------------------------------------------------------------------------- a = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). b = Acceptable measurement (not normally used). c = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). d = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). e = Not reported (lost sample; unredeemably bad measurement). f = Mean of replicate measurements. g = Manual chromatographic peak measurement. h = Irregular digital chromatographic peak integration. i = Sample not drawn for this measurement from this bottle (not normally used). ---------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2002-03 AGENCY : IOS, Ocean Science and Productivity. Sidney, BC COUNTRY : Canada PROJECT : SoG SCIENTIST : Cummins P. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Strait of Georgia/J.de Fuca Strait STATION : 65 EVENT NUMBER : 22 LATITUDE : 48 15.85000 N ! (deg min) LONGITUDE : 123 9.97000 W ! (deg min) WATER DEPTH : 121 *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 77511 temperature ' ' secondary conductivity ' ' secondary Fluorometer ' ' Seapoint transmissometer ' ' primary Oxygen ' ' SBE $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V 5.24 Comments from secondary file: D:\Data\2002\2002-03\2002-03-0022.oxy ------------------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- SBE_IOS 2.1 2002/05/24 14:02:17 1331 1331 BINAVE 4.0.1 2002/05/24 14:03:17 1331 11 CALIB 10.2 2002/05/28 10:55:37 11 11 REMOVECH 6.0 2002/05/28 14:23:53 11 11 REORDER 1.1 2002/05/28 15:02:20 ? ? HDREDIT2 1.3 2002/05/28 15:02:28 ? ? ADDSAMP 3.0 2002/05/29 13:09:58 11 11 MERGE 2.8 2002/10/24 13:59:13 11 11 MERGE 2.8 2002/10/24 13:59:56 11 11 ADDCHANS 1.0 2002/10/24 14:08:48 ? ? REMOVECH 6.0 2002/10/24 15:50:29 11 11 CLEAN 3.9 2002/10/24 15:51:35 11 11 HDREDIT2 1.5 2002/12/23 15:46:36 ? ? HDREDIT2 1.51 2003/01/06 15:58:57 ? ? $END $REMARKS -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.0 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = Q:\CTD\2002-03\ios\2203rcal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 8 Chlorophyll:Fluorescence:Seap mg/m^3 10 -0.6000000E-01 0.1000000E+01 11 Salinity:T0:C0 PSS-78 10 -0.3800000E-02 0.1000000E+01 12 Salinity:T1:C1 PSS-78 10 0.5000000E-03 0.1000000E+01 -The following CHANNEL(S) were removed from file. Scan_Number Temperature:Secondary Conductivity:Primary Conductivity:Secondary Oxygen:Dissolved:SBE Salinity:T1:C1 Flag -The following ADDSAMP parameters were used: Sample Number Lookup File: d:\data\2002\2002-03\numbers.csv Bottle Channel Name: Bottle_Number -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, Chlorophyll:Fluorescence:Seapoint, Bottle_Number, Salinity:T0:C0 Secondary Channels to Include: Oxygen:Dissolved Primary file : D:\Data\2002\2002-03\2002-03-0022.sam Secondary file: D:\Data\2002\2002-03\2002-03-0022.oxy Comments from secondary file: D:\Data\2002\2002-03\2002-03-0022.oxy ------------------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.004 Sodium Thiosulfate concentration = 0.722 Volume of iodate standard (cm**3) = 10.08 Enter Normalitity of iodate standard = 0.01012953 -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, Chlorophyll:Fluorescence:Seapoint, Bottle_Number, Salinity:T0:C0, Oxygen:Dissolved Secondary Channels to Include: Salinity:Bottle Primary file : D:\Data\2002\2002-03\2002-03-0022.mrg Secondary file: D:\Data\2002\2002-03\2002-03-0022.sal -The following CHANNEL(S) were removed from file. NewLat CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Remove Sea-Bird comments from the header. $END *COMMENTS Comments from secondary file: D:\Data\2002\2002-03\2002-03-0022.oxy ------------------------------------------------------------------- Sample 96 oxygen titration missing from file, data entered from worksheet. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed frozen using a Technicon AAII autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences utrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS !Name Units Fmla Pad Coefficients !----------------------------------- -------- ---- ------ ------------ Chlorophyll:Fluorescence:Seapoint mg/m^3 10 -9.9 () (-0.6E-01 1) Salinity:T0:C0 PSS-78 10 -9.9 () (-0.38E-02 1) Salinity:T1:C1 PSS-78 10 -9.9 () (0.5E-03 1) $END !-1-- --2--- ---3---- --4--- ---5--- 6- ---7---- ---8--- 9 ---10--- 1 !Samp Pressu Temperat Transm Fluores Bo Salinity Oxygen: F Salinity F !le_ re ure: issivi cence: tt :T0:C0 Dissolv l :Bottle l !Numb Primary ty URU: ~u ed ~ ~ !er Seapoin mb e l ! t er d e !---- ------ -------- ------ ------- -- -------- ------- - -------- - *END OF HEADER 92 119.1 8.2096 31.0 0.198 1 31.1204 5.358 31.1310 93 100.1 8.2075 34.1 0.199 2 31.1186 5.330 31.1280 94 100.0 8.2063 36.0 0.193 3 31.1197 5.276 31.1228 95 74.7 8.2023 36.9 0.186 4 31.1210 5.385 -9.9000 96 49.8 8.2014 39.4 0.210 5 31.0665 5.372 -9.9000 97 39.9 8.2053 41.2 0.201 6 30.9645 5.420 -9.9000 98 30.0 8.2140 42.0 0.217 7 30.9146 5.403 -9.9000 99 20.1 8.2273 42.6 0.225 8 30.8587 5.594 -9.9000 100 9.9 8.2509 42.7 0.320 9 30.7239 5.670 -9.9000 101 5.1 8.2307 43.1 0.334 10 30.6774 5.816 -9.9000 102 1.4 8.2156 43.4 0.351 11 30.6629 -99.990 -9.9000