*2013/12/16 15:25:00.98 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2001/10/13 19:11:31.000 NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------- --------- -------------- -------------- 1 Salinity:Bottle PSS-78 33.8474 33.8474 2 Sample_Number n/a 50 50 3 Bottle_Number n/a 1 1 4 Pressure decibar 175 175 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' f9.4 R4 ' ' 2 -99 ' ' 5 I I 0 3 -99 ' ' 3 I I 0 4 -99 ' ' 7 F R4 1 $END *ADMINISTRATION MISSION : 2001-30 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, Covariability, Endeavour Ridge SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : NE Pacific STATION : JFD5 EVENT NUMBER : 64 LATITUDE : 48 15.76000 N ! (deg min) LONGITUDE : 123 59.98000 W ! (deg min) WATER DEPTH : 179 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 3.4.5 2001/10/18 16:27:06 1 1 HDREDIT2 1.3 2002/03/19 10:39:46 ? ? CHGUNITS 1.3 2002/03/19 10:41:44 1 1 CALIB 10.2 2002/03/19 12:09:06 1 1 REMOVECH 6.0 2004/04/02 11:01:27 1 1 HDREDIT2 1.9 2004/04/02 11:03:40 ? ? SORT 3.4.1 2004/04/02 11:04:28 1 1 CLEAN 4.5 2004/04/02 11:04:37 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:25:00 1 1 $END $REMARKS CHANGE units: - No units changed -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = M:\Data\oxy\2130\2130oxy.CCF WARNING: No calibration done on file M:\Data\oxy\2130\21300064.che -No channels were removed. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Remove Sea-Bird comments from the header. $END *COMMENTS No RAC file available. The SBE Oxygen data should be considered to be within +/- 5%. Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. *CALIBRATION *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre !---1---- -2-- 3- --4--- !Salinity Samp Bo Pressu !:Bottle le_ tt re ! Numb ~u ! er mb ! er !-------- ---- -- ------ *END OF HEADER 33.8474 50 1 175.0