*2014/11/20 09:53:06.64 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2001/06/28 04:29:35.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 17 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 15 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 150 166 2 Pressure decibar 1.3 368 3 Temperature:Primary 'deg C (ITS90)' 8.7141 15.7979 4 Transmissivity %/metre 12.6 51.3 5 Fluorescence:URU:Seapoint mg/m^3 0.6E-02 3.254 6 Salinity:T0:C0 PSS-78 19.9697 31.1805 7 Bottle_Number n/a 1 17 8 Oxygen:Dissolved mL/L 3.97 7.01 9 Salinity:Bottle PSS-78 31.0352 31.1816 10 Nitrate_plus_Nitrite umol/L 0.6 29 11 Flag:Nitrate_plus_Nitrite n/a 12 Silicate umol/L 16.1 52.8 13 Flag:Silicate n/a 14 Phosphate umol/L 0.26 2.55 15 Flag:Phosphate n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 3 I I 0 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' ' ' F9.4 R4 ' ' 10 -99 ' ' 6 F R4 1 11 -99 ' ' 2 NQ C ' ' 12 -99 ' ' 6 F R4 1 13 -99 ' ' 2 NQ C ' ' 14 -99 ' ' 7 F R4 2 15 -99 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2001-19 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Strait of Georgia, Juan de Fuca SCIENTIST : Masson D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : SoG/JdeF STATION : 39 EVENT NUMBER : 45 LATITUDE : 49 9.83000 N ! (deg min) LONGITUDE : 123 33.03000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0550 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 75636 temperature ' ' secondary conductivity ' ' secondary transmissometer ' ' primary Fluorometer ' ' Seapoint $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V1.20 Comments from secondary file: D:\DATA\2001\2001-19_SofG\21190045.dox -------------------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.8 2001/09/11 17:10:51 2057 2057 BINAVE 4.0.1 2001/10/12 09:37:49 2057 17 MERGE 2.6.1 2001/10/12 09:39:39 17 17 CALIB 10.0 2001/10/12 09:50:41 17 17 MERGE 2.6.1 2001/10/24 11:00:23 17 17 REORDER 1.1 2001/10/24 11:29:27 ? ? MERGE 3.1 2004/04/05 15:57:42 17 17 HDREDIT2 1.9 2004/04/05 16:00:50 ? ? SORT 3.4.1 2004/04/05 16:01:20 17 17 CLEAN 4.5 2004/04/05 16:01:31 17 17 CHANGE_FLAGS 1.0 2013/07/29 14:28:38 17 17 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:23:57 17 17 CHANGE_FLAGS 2.0 2014/11/20 09:53:06 17 17 $END $REMARKS -The following BINAVE parameters were used: Bin channel = Sample_Number Averaging interval = 1.0 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, Chl_fluorescence:Seapoint, Salinity:T0:C0, Bottle_Number Secondary Channels to Include: Dissolved_Oxygen:volume Primary file : D:\DATA\2001\2001-19_SofG\21190045.avt Secondary file: D:\DATA\2001\2001-19_SofG\21190045.dox Comments from secondary file: D:\DATA\2001\2001-19_SofG\21190045.dox -------------------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.004 Sodium Thiosulfate concentration = 0.723 Volume of iodate standard (cm**3) = 10.02 Enter Normalitity of iodate standard = 0.01012956 -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = d:\data\2001\2001-19_SofG\cal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Chl_fluorescence:Seapoint ug/l 10 -0.1500000E+00 0.1000000E+01 6 Salinity:T0:C0 PSS-78 10 -0.1100000E-02 0.1000000E+01 -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Transmissivity, Chl_fluorescence:Seapoint, Salinity:T0:C0, Bottle_Number, Dissolved_Oxygen:volume Secondary Channels to Include: salinity:bottle Primary file : D:\DATA\2001\2001-19\21190045.cor Secondary file: D:\DATA\2001\2001-19\21190045.sal -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Flag:Nitrate_plus_Nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate Primary file : H:\New_Archive\2001\2001-19\hydro\21190045.che Secondary file: H:\New_Archive\2001\2001-19\hydro\21190045.srt_nut Comments from secondary file: H:\New_Archive\2001\2001-19\hydro\21190045.srt_nut -------------------------------------------------- -The following SORT parameters were used. Sorted by channel: Sample_Number Pressure channel sorted according to values in sort channel -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Remove Sea-Bird comments from the header. $END *COMMENTS Comments from secondary file: D:\DATA\2001\2001-19_SofG\21190045.dox -------------------------------------------------------------------- Sample 158 oxygen value removed, titration incomplete (suspect large air bu Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed frozen using a Technicon AAII autoanalyzer following methods described in Barwell-Clarke and Whitney (1996). References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! --------------------------- -------- ---- ------ ------------ Chl_fluorescence:Seapoint ug/l 10 -9.9 () (-0.15 1) Salinity:T0:C0 PSS-78 10 -9.9 () (-0.11E-02 1) $END !-1-- --2--- ---3---- --4-- ---5--- ---6---- 7- ---8--- ---9---- --10- - --12- - --14-- - !Samp Pressu Temperat Trans Fluores Salinity Bo Oxygen: Salinity Nitra F Silic F Phosph F !le_ re ure: missi cence: :T0:C0 tt Dissolv :Bottle te_ l ate l ate l !Numb Primary vity URU: ~u ed plus_ ~ ~ ~ !er Seapoin mb Nitri t t t ! t er te e e e !---- ------ -------- ----- ------- -------- -- ------- -------- ----- - ----- - ------ - *END OF HEADER 166 1.3 15.7979 12.6 3.254 19.9697 17 7.010 -99.0000 0.6 0 22.6 0 0.26 0 165 5.6 12.6750 36.0 2.639 27.8219 16 6.680 -99.0000 3.7 0 16.1 0 0.68 0 164 10.4 11.6393 40.9 1.639 28.7829 15 5.930 -99.0000 9.9 0 24.7 0 1.31 0 163 20.7 11.0945 50.5 0.442 29.5249 14 5.720 -99.0000 11.1 0 25.5 0 1.47 0 162 30.4 10.4381 48.9 0.339 29.6929 13 5.020 -99.0000 17.3 0 35.5 0 1.83 0 161 40.7 9.9272 49.9 0.159 30.0028 12 4.620 -99.0000 21.6 0 40.6 0 2.11 0 160 50.8 9.4493 49.9 0.066 30.2324 11 4.300 -99.0000 24.5 0 45.5 0 2.26 0 159 75.9 8.9413 51.1 0.018 30.3622 10 3.970 -99.0000 28.1 0 52.7 0 2.52 0 158 100.7 8.7543 51.3 0.007 30.5464 9 -99.000 -99.0000 29.0 0 52.0 0 2.55 0 157 126.5 8.9757 47.5 0.006 30.7575 8 4.340 -99.0000 26.7 0 47.4 0 2.27 0 156 150.8 8.7779 46.9 0.006 30.8117 7 4.310 -99.0000 27.2 0 50.2 0 2.37 0 155 177.3 8.8315 44.0 0.011 30.8556 6 4.300 -99.0000 26.8 0 49.9 0 2.35 0 154 203.0 8.9939 45.2 0.017 30.9785 5 4.320 -99.0000 25.8 0 45.7 0 2.28 0 153 250.0 8.8894 44.8 0.017 31.0338 4 4.240 31.0352 26.7 0 48.9 0 2.34 0 152 299.0 8.7141 42.3 0.014 31.0556 3 4.200 31.0646 26.4 0 48.4 0 2.36 0 151 347.9 8.7461 37.5 0.019 31.1547 2 4.120 31.1677 27.3 0 52.8 0 2.47 0 150 368.0 8.7701 35.9 0.026 31.1805 1 4.080 31.1816 27.4 0 52.3 0 2.52 0