*2013/12/16 15:22:55.15 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2001/02/11 05:06:29.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 9 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 10 21 2 Pressure decibar 1.8 235.2 3 Temperature:Primary 'deg C (ITS90)' 7.1395 7.322 4 Salinity:T0:C0 PSS-78 30.9351 31.0823 5 Transmissivity %/metre 42.1 48.4 6 Fluorescence:URU:Seapoint mg/m^3 0.18 0.591 7 Bottle_Number n/a 1 12 8 Oxygen:Dissolved mL/L 5.83 6 9 Salinity:Bottle PSS-78 31.0782 31.0782 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 3 I I 0 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' ' ' f9.4 R4 ' ' $END $REMARKS This file converted from Sea-Bird file: d:\data\2001\2001-04\21040004.ros Comments from secondary file: d:\data\2001\2001-04\21040004.dox --------------------------------------------------------------- Raw data in file oxydata\2001-04\2001-040004.o2 VIO3 = 10.02 ! Volume of iodate standard (cm**) NIO3 = .01013127 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) $END *ADMINISTRATION MISSION : 2001-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Aquaculture SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : WEST COAST STATION : KN1 EVENT NUMBER : 4 LATITUDE : 50 38.14000 N ! (deg min) LONGITUDE : 126 25.27000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0585 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 77511 temperature ' ' secondary conductivity ' ' secondary Seapoint ' ' ' ' transmissometer ' ' 192D $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V1.19 Comments from secondary file: d:\data\2001\2001-04\21040004.dox --------------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.8 2001/03/19 11:58:57 1164 1164 DESPIKE 2.1 2001/03/19 12:08:23 1164 1164 BINAVE 4.0.1 2001/03/19 12:13:21 1164 12 MERGE 2.6.1 2001/03/19 14:16:47 12 12 MERGE 2.6.1 2001/03/19 14:17:45 12 12 CALIB 10.0 2001/10/25 13:06:07 12 12 REORDER 1.1 2001/10/25 13:21:24 ? ? HDREDIT2 1.9 2004/04/01 11:27:59 ? ? SORT 3.4.1 2004/04/01 11:28:55 12 12 CLEAN 4.5 2004/04/01 11:29:05 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:22:55 12 12 $END $REMARKS -The following DESPIKE parameters were used: DESPIKE TABLE CHANNEL FIT OVER- MIN MAX MIN MAX SPIKE WIDTH LAP VALUE VALUE STDDEV STDDEV TOL. -------------------- ----- ----- ------- ------- ------- ------- ----- Pressure 55 5 0.00 1000.00 0.10000 999.000 3.00 Temperature:Primary 55 5 1.00 25.00 0.00100 999.000 3.00 Temperature:Secondar 55 5 1.00 25.00 0.00100 999.000 3.00 Salinity:T0:C0 55 5 2.00 35.00 0.00100 999.000 3.00 Salinity:T1:C1 55 5 2.00 35.00 0.00100 999.000 3.00 -The following BINAVE parameters were used: Bin channel = Sample_Number Averaging interval = 1.0 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Temperature:Secondary, Salinity:T0:C0, Salinity:T1:C1, Transmissivity, Chl_fluorescence:Seapoint, Bottle_Number Secondary Channels to Include: Dissolved_Oxygen:volume Primary file : d:\data\2001\2001-04\21040004.avt Secondary file: d:\data\2001\2001-04\21040004.dox Comments from secondary file: d:\data\2001\2001-04\21040004.dox --------------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.005 Sodium Thiosulfate concentration = 0.718 Volume of iodate standard (cm**3) = 10.02 Enter Normalitity of iodate standard = 0.01013130 -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Temperature:Secondary, Salinity:T0:C0, Salinity:T1:C1, Transmissivity, Chl_fluorescence:Seapoint, Bottle_Number, Dissolved_Oxygen:volume Secondary Channels to Include: Salinity:bottle Primary file : d:\data\2001\2001-04\21040004.tab Secondary file: d:\data\2001\2001-04\21040004.sal -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = D:\DATA\2001\2001-04\2104rcal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.2000000E-01 0.1000000E+01 6 Salinity:T1:C1 PSS-78 10 0.1700000E-01 0.1000000E+01 8 Chl_fluorescence:Seapoint ug/l 10 -0.8000000E-01 0.1000000E+01 -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Remove Sea-Bird comments from the header. $END *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! --------------------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -9.9 () (0.2E-01 1) Salinity:T1:C1 PSS-78 10 -9.9 () (0.17E-01 1) Chl_fluorescence:Seapoint ug/l 10 -9.9 () (-0.8E-01 1) $END !--1--- --2--- ---3---- ---4---- --5-- ---6--- 7- ---8--- ---9---- !Sample Pressu Temperat Salinity Trans Fluores Bo Oxygen: Salinity !_ re ure: :T0:C0 missi cence: tt Dissolv :Bottle !Number Primary vity URU: ~u ed ! Seapoin mb ! t er !------ ------ -------- -------- ----- ------- -- ------- -------- *END OF HEADER 21 1.8 7.1395 30.9351 48.1 0.527 12 6.000 -99.0000 20 9.9 7.1513 30.9364 48.4 0.556 11 5.950 -99.0000 19 20.4 7.1615 30.9392 48.4 0.591 10 5.960 -99.0000 18 30.6 7.1616 30.9379 47.9 0.570 9 5.950 -99.0000 17 50.4 7.1738 30.9836 47.5 0.388 8 5.950 -99.0000 16 76.0 7.1711 31.0000 46.9 0.370 7 5.980 -99.0000 15 100.8 7.1874 31.0134 46.3 0.333 6 5.940 -99.0000 14 125.5 7.2104 31.0423 44.9 0.231 5 5.940 -99.0000 13 150.2 7.2146 31.0481 44.7 0.244 4 5.940 -99.0000 12 175.1 7.2735 31.0672 43.9 0.186 3 5.940 -99.0000 11 201.1 7.2170 31.0494 44.3 0.225 2 5.870 -99.0000 10 235.2 7.3220 31.0823 42.1 0.180 1 5.830 31.0782