*2013/12/16 15:22:07.30 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2000/08/25 14:00:30.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 8 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 263 274 2 Pressure decibar 0.7 234.8 3 Temperature:Primary 'deg C (ITS90)' 8.1189 16.3324 4 Transmissivity %/metre 37 55.2 5 Fluorescence:URU:Seapoint mg/m^3 0.163 1.295 6 Salinity:T0:C0 PSS-78 17.2151 27.2903 7 Bottle_Number n/a 1 12 8 Oxygen:Dissolved mL/L 0 4.215 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 3 I I 0 8 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from Sea-Bird file: d:\data\2000\2000-26\20260041.ros Comments from secondary file: d:\data\2000\2000-26\20260041.dox --------------------------------------------------------------- Raw data in file oxydata\2000-26\2000-260041.o2 VIO3 = 10.02 ! Volume of iodate standard (cm**) NIO3 = 0.01013126 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) $END *ADMINISTRATION MISSION : 2000-26 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Pelagic Fish SCIENTIST : Thomson R.E. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : N.E. Pacific STATION : FRS1 EVENT NUMBER : 41 LATITUDE : 51 2.33000 N ! (deg min) LONGITUDE : 126 42.93000 W ! (deg min) WATER DEPTH : 240 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre SERIAL NUMBER : 0550 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 75636 temperature ' ' secondary conductivity ' ' secondary Seapoint ' ' ' ' transmissometer ' ' 333DR fluorometer ' ' 'sea tech' surface ' ' 'degrees = 0.0' $END $REMARKS SOFTWARE VERSION SEASAVE WIN32 V1.18 Comments from secondary file: d:\data\2000\2000-26\20260041.dox --------------------------------------------------------------- Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.5 2000/08/28 16:09:43 1164 1164 DESPIKE 1.5 2000/08/28 16:11:40 1164 1164 BINAVE 4.0 2000/08/28 16:53:21 1164 12 MERGE 2.5.1 2000/08/29 09:45:54 12 12 CALIB 11.4 2004/03/30 19:36:51 12 12 REMOVECH 6.0 2004/03/30 19:39:03 12 12 HDREDIT2 1.9 2004/03/30 19:43:27 ? ? SORT 3.4.1 2004/03/30 19:43:57 12 12 CLEAN 4.6.1 2004/04/14 15:33:12 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:22:07 12 12 $END $REMARKS -The following DESPIKE parameters were used: DESPIKE TABLE CHANNEL FIT OVER- MIN MAX MIN MAX SPIKE WIDTH LAP VALUE VALUE STDDEV STDDEV TOL. -------------------- ----- ----- ------- ------- ------- ------- ----- Pressure 55 5 0.00 6000.00 0.10000 999.000 3.00 Temperature:Primary 55 5 2.00 25.00 0.00100 999.000 3.00 Temperature:Secondar 55 5 2.00 25.00 0.00100 999.000 3.00 Salinity:T0:C0 55 5 0.00 35.00 0.00100 999.000 3.00 -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.0 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Temperature:Secondary, Transmissivity, Chl_fluorescence:Seapoint, Salinity:T0:C0, Salinity:T1:C1, Voltage:4, Bottle_Number Secondary Channels to Include: Dissolved_Oxygen:volume, Flask_Number Primary file : d:\data\2000\2000-26\20260041.avt Secondary file: d:\data\2000\2000-26\20260041.dox Comments from secondary file: d:\data\2000\2000-26\20260041.dox --------------------------------------------------------------- C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following OXYCALC parameters were used Blank = 0.005 Sodium Thiosulfate concentration = 0.722 Volume of iodate standard (cm**3) = 10.02 Enter Normalitity of iodate standard = 0.01013130 -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = H:\New_Archive\2000\2000-26\hydro\2026RCAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 7 Salinity:T0:C0 PSS-78 10 -0.5000000E-02 0.1000000E+01 8 Salinity:T1:C1 PSS-78 10 0.5000000E-02 0.1000000E+01 -The following CHANNEL(S) were removed from file. Temperature:Secondary Salinity:T1:C1 Voltage:4 Flask_Number -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set last 4 characters of file name to event - Remove Sea-Bird comments from the header. $END *COMMENTS Comments from secondary file: d:\data\2000\2000-26\20260041.dox --------------------------------------------------------------- Sample 274 oxygen, seawater too murky for titration system. Incomplete titr oxygen value of 4.967 deleted. Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -9.99 () (-0.5E-02 1) Salinity:T1:C1 PSS-78 10 -9.99 () (0.5E-02 1) $END !--1--- --2--- ---3---- --4-- ---5--- ---6---- 7- ---8--- !Sample Pressu Temperat Trans Fluores Salinity Bo Oxygen: !_ re ure: missi cence: :T0:C0 tt Dissolv !Number Primary vity URU: ~u ed ! Seapoin mb ! t er !------ ------ -------- ----- ------- -------- -- ------- *END OF HEADER 274 0.7 16.3324 37.0 1.295 17.2151 12 -99.000 273 10.1 12.0049 52.6 0.361 23.8098 11 4.215 272 20.2 10.0665 54.6 0.172 25.8268 10 3.862 271 30.2 9.6224 54.8 0.163 26.3888 9 3.571 270 50.3 8.6426 54.8 0.170 26.9634 8 1.644 269 75.2 8.4867 54.9 0.180 27.2097 7 1.591 268 100.2 8.5622 55.2 0.173 27.2637 6 2.428 267 125.2 8.4928 53.9 0.191 27.2829 5 1.070 266 150.2 8.3170 51.1 0.280 27.2805 4 0.000 265 175.1 8.2069 52.9 0.326 27.2851 3 0.000 264 199.6 8.1434 53.4 0.344 27.2865 2 0.000 263 234.8 8.1189 52.6 0.384 27.2903 1 0.000