*2013/12/16 15:20:30.97 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2000/03/12 14:44:10.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 9 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Pressure decibar 1.3 83.4 2 Temperature:Primary 'deg C (ITS90)' 8.0567 8.9241 3 Salinity:T0:C0 PSS-78 26.645 31.8716 4 Transmissivity %/metre 10.4 58 5 Fluorescence:URU:Seapoint mg/m^3 0.91E-01 1.22 6 pH:SBE n/a 8.02 8.23 7 Bottle_Number n/a 1 7 8 Sample_Number n/a 257 263 9 Oxygen:Dissolved mL/L 4.899 7.24 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 8 F ' ' 3 6 -99 ' ' 7 F ' ' 2 7 -99 ' ' 3 I I 0 8 -99 ' ' 5 F ' ' 0 9 -99 ' ' 8 F ' ' 3 $END *ADMINISTRATION MISSION : 2000-02 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Wide Straits, Effingham Inlet SCIENTIST : Stucchi D. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : Juan de Juca Strait, Effingham Inlet STATION : EF11 EVENT NUMBER : 76 LATITUDE : 48 59.10000 N ! (deg min) LONGITUDE : 125 11.01000 W ! (deg min) WATER DEPTH : 85 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- CALIB 8.9 2000/05/30 15:49:05 7 7 REMOVECH 5.0 2000/11/16 13:13:12 7 7 REMOVECH 5.0 2000/11/16 13:29:47 7 7 CALIB 10.0 2001/09/25 13:50:58 7 7 HDREDIT2 1.9 2004/01/19 11:54:53 ? ? REMOVECH 6.0 2004/01/19 12:00:10 7 7 SORT 3.4.1 2004/01/19 12:00:59 7 7 CLEAN 4.5 2004/01/19 12:01:07 7 7 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:20:30 7 7 $END $REMARKS -The following CALIB parameters were used: Calibration type = Raw Mode: ONLY - calibration specs from Cal File only. Pressure offset = 0.0 Calibration file = D:\DATA\2000\2000-02\sal_fix.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 psu 10 0.3500000E-02 0.1000000E+01 -The following CHANNEL(S) were removed from file. Temperature:Secondary Salinity:T1:C1 -The following CHANNEL(S) were removed from file. Flask_Number -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = W:\CTD\2000-02\2002fcal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 6 Chl_fluorescence:Seapoint ug/l 10 -0.4500000E-01 0.1000000E+01 -The following CHANNEL(S) were removed from file. Sample_Number -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. $END *CALIBRATION $TABLE: RAW CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- ----- ---- ------ ------------ Salinity:T0:C0 psu 10 -99 (0.35E-02 1) $END $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! --------------------------- ------ ---- ------ ------------ Chl_fluorescence:Seapoint ug/l 10 -9.99 () (-0.45E-01 1) $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. !--1--- ---2---- ---3---- --4-- ---5--- --6--- 7- -8-- ---9--- !Pressu Temperat Salinity Trans Fluores pH:SBE Bo Samp Oxygen: !re ure: :T0:C0 missi cence: tt le_ Dissolv ! Primary vity URU: ~u Numb ed ! Seapoin mb er ! t er !------ -------- -------- ----- ------- ------ -- ---- ------- *END OF HEADER 1.3 8.0567 26.6450 34.0 1.115 8.23 7 263. 7.240 10.2 8.3728 29.4725 54.8 1.220 8.19 6 262. 6.693 20.2 8.3391 30.1108 58.0 0.428 8.13 5 261. 6.324 29.6 8.4406 30.4785 57.7 0.237 8.09 4 260. 5.888 39.1 8.5792 30.8357 54.2 0.173 8.05 3 259. 5.444 50.0 8.8143 31.2909 47.6 0.094 8.02 2 258. 4.899 83.4 8.9241 31.8716 10.4 0.091 8.06 1 257. 5.102