*2014/11/20 09:52:46.45 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 2000/02/15 19:32:15.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 15 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 15 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- --------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 176 190 2 Pressure decibar 2.7 1501.3 3 Temperature:Primary 'deg C (ITS90)' 2.5024 7.6081 4 Salinity:T0:C0 PSS-78 32.1006 34.4866 5 Transmissivity %/metre 56.3 64.7 6 PAR uE/m^2/sec 1.3 1.3 7 Fluorescence:URU:Seapoint mg/m^3 -0.2E-02 0.673 8 Oxygen:Dissolved mL/L 0.34 7.05 9 Salinity:Bottle PSS-78 32.1014 34.4855 10 Phosphate umol/L 1.32 3.22 11 Nitrate_plus_Nitrite umol/L 13.9 44.9 12 Silicate umol/L 24.4 159.3 13 Chlorophyll:Extracted mg/m^3 0.15 0.47 14 pH n/a 7.5111 8.0116 15 Flag:pH n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 9 F ' ' 4 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 7 F ' ' 1 7 -99 ' ' 8 F ' ' 3 8 -99 ' ' 8 F ' ' 3 9 -99 ' ' 9 F ' ' 4 10 -99 ' ' 7 F R4 2 11 -99 ' ' 6 F R4 1 12 -99 ' ' 6 F R4 1 13 -99 ' ' 7 F R4 2 14 -99 ' ' 9 F R4 4 15 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 2000-01 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : Haida Eddy SCIENTIST : Robert M. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : QCSound/Hecate/NE Pacific STATION : HED09 EVENT NUMBER : 86 LATITUDE : 52 20.01000 N ! (deg min) LONGITUDE : 134 40.04000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-911plus SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 63507 temperature ' ' secondary conductivity ' ' secondary Seapoint ' ' ' ' transmissometer ' ' 192D irradiance ' ' 4565 $END $REMARKS SOFTWARE VERSION 4.238 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.5 2000/05/29 13:06:53 1091 1091 BINAVE 3.0 2000/06/05 13:25:15 1091 15 CALIB 8.9 2000/06/05 14:04:47 15 15 MERGE 2.41 2000/06/29 09:53:00 15 15 MERGE 2.5.1 2000/11/16 11:44:51 15 15 CALIB 10.0 2001/10/29 16:08:28 15 15 HDREDIT2 1.1 2001/10/29 16:59:12 ? ? HDREDIT2 1.2 2001/12/24 10:48:34 ? ? HDREDIT2 1.51 2003/04/21 18:51:30 ? ? CLEAN 4.2 2003/04/21 18:52:45 15 15 SORT 3.4.1 2004/02/15 13:05:53 15 15 SORT 3.5 2005/07/28 11:09:40 15 15 MERGE 3.3 2005/07/28 11:11:31 15 15 SORT 3.5 2005/07/28 11:13:47 15 15 HDREDIT2 2.5 2005/07/28 14:09:08 ? ? CLEAN 4.8 2005/07/28 14:13:08 15 15 HDREDIT2 2.5 2005/11/04 13:53:34 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:28:15 15 15 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:20:24 15 15 CHANGE_FLAGS 2.0 2014/11/20 09:52:46 15 15 $END $REMARKS -The following BINAVE parameters were used: Bin channel = Bottle_Number Averaging interval = 1.0 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Pressure offset = 0.0 Calibration file = w:\ctd\2000-01\2001rcal.ccf Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 5 Salinity:T0:C0 PSS-78 10 0.3900000E-02 0.1000000E+01 6 Salinity:T1:C1 PSS-78 10 0.4600000E-02 0.1000000E+01 -The following MERGE parameters were used: Merge Channel: Bottle_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Temperature:Secondary, Salinity:T0:C0, Salinity:T1:C1, Transmissivity, Irradiance (PAR), Chl_fluorescence:Seapoint Secondary Channels to Include: Sample_Number, Dissolved_Oxygen:volume, Salinity:Bottle Primary file : W:\CTD\2000-01\HYDRO\20010086.rac Secondary file: W:\CTD\2000-01\HYDRO\20010086.cln -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Salinity:T0:C0, Transmissivity, Irradiance (PAR), Chl_fluorescence:Seapoint, Dissolved_Oxygen:volume, Salinity:Bottle Secondary Channels to Include: Phosphate, Nitrate_plus_Nitrite, Silicate, Chlorophyll Primary file : D:\DATA\2000\2000-01\20010086.che Secondary file: D:\DATA\2000\2000-01\20010086.nut -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Calibration file = W:\CTD\2000-01\2001FCAL.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 7 Chl_fluorescence:Seapoint ug/l 10 -0.5200000E-01 0.1000000E+01 CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -SORT parameters: 2005/07/28 11:09:40 Sorted in descending order of channel Sample_Number -The following MERGE parameters were used: 2005/07/28 11:11:31 2005/07/28 11:11:31 2005/07/28 11:11: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Inorganic, Flag:Carbon:Dissolved:Inorganic, Alkalinity:Total, Flag:Alkalinity:Total, pH, Flag:pH Primary file : H:\Data Processing\Carbon\Haida\2000-01\2000-01-0086.srtche Secondary file: H:\Data Processing\Carbon\Haida\2000-01\2000-01-0086.srtios Comments from secondary file: H:\Data Processing\Carbon\Haida\2000-01\2000-01-0086.srtios ----------------------------------------------------------- -SORT parameters: 2005/07/28 11:10:59 Sorted in descending order of channel Sample_Number -SORT parameters: 2005/07/28 11:13:47 Sorted in ascending order of channel Pressure -HEADER EDITS: 2005/07/28 14:09:08 Applied edit header: H:\Data Processing\Carbon\Haida\2000-01\DIC_ALK_pH.txt Channel 18: pH [n/a] Format: F8.4 ==> F9.4 -CLEAN functions: 2005/07/28 14:13:07 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. -HEADER EDITS: 2005/11/04 13:53:34 Applied edit header: O:\Data Processing\Header Comments\quality_flags.txt $END *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll samples are collected in duplicate in calibrated polycarbonate bottles (~330ml), then filtered onto 25mm MFS GF/75 filters at <70mmHg vacuum. The filters are placed in glass scintillation vials and immediately frozen at -20ºC until analysis. The chlorophyll is extracted in 10 ml of 90% acetone for 24h at -20ºC, then brought to room temperature and the extract is decanted and measured using a Turner Designs 10-AU-005-CE fluorometer, which has been calibrated with solutions of commercially prepared chlorophyll. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. Dissolved inorganic carbon (DIC) and total alkalinity (Alk) samples were collected in 500 mL glass bottles, according to the DOE Handbook of Methods (1994), poisoned with 100 microL of saturated HgCl2, and kept at 4 C during transport back to shore for analysis at the Institute of Ocean Sciences. Total dissolved inorganic carbon was determined by coulometric titration with photometric detection using a SOMMA (Johnson et al., 1985; 1987), and Alk was determined by potentiometric titration in an open cell with 0.1 M HCl (Dickson et al., 2003; Haraldsson et al., 1997). The accuracy was assured by calibrating against Certified Reference Materials, CRM’s (DOE, 1994; Dickson 2001; Dickson et al., 2003), supplied by Andrew Dickson (Scripps Institution of Oceanography, San Diego, USA) and analyzed once a day. The measured and certified values of the CRMs differed by 0.7-1.1 µmol kg-1 for DIC and between 0.9 and 2.4 µmol kg-1 for AT. DIC analytical precision: 0.9 umol/kg based on other cruises. Alk analytical precision: 1 ueq/kg based on other cruises. pH samples were collected directly into 5-cm quartz cells and analyzed spectrophotometrically (Clayton and Byrne, 1993) using an Ocean Optics spectrophotometer within 2 hours of collection. Values given corrected to in situ T & P. Analytical precision: 0.0026 *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! --------------------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -9.99 () (0.39E-02 1) Salinity:T1:C1 PSS-78 10 -9.99 () (0.46E-02 1) Chl_fluorescence:Seapoint ug/l 10 -9.99 () (-0.52E-01 1) $END !-1-- --2--- ---3---- ---4---- --5-- --6--- ---7--- ---8--- ---9---- --10-- --11- --12- --13-- ---14--- - !Samp Pressu Temperat Salinity Trans PAR Fluores Oxygen: Salinity Phosph Nitra Silic Chloro pH F !le_ re ure: :T0:C0 missi cence: Dissolv :Bottle ate te_ ate phyll: l !Numb Primary vity URU: ed plus_ Extrac ~ !er Seapoin Nitri ted p ! t te H !---- ------ -------- -------- ----- ------ ------- ------- -------- ------ ----- ----- ------ -------- - *END OF HEADER 190 2.7 7.1930 32.1006 56.3 1.3 0.430 6.710 32.1014 1.32 13.9 25.4 0.47 8.0116 0 189 10.0 7.1900 32.1008 58.3 1.3 0.640 6.680 32.1014 1.34 14.0 25.4 0.44 8.0093 0 188 25.7 7.1864 32.1011 58.1 1.3 0.673 6.670 32.1021 1.33 14.0 25.4 0.41 8.0013 0 187 49.9 7.2260 32.1179 62.8 1.3 0.205 6.740 32.1198 1.33 14.1 25.1 0.15 8.0114 0 186 76.5 7.2478 32.3329 60.8 1.3 0.338 7.050 32.3374 1.34 14.3 24.4 0.36 -99.0000 0 185 99.5 7.1586 32.4230 60.6 1.3 0.436 6.640 32.4285 1.37 14.7 25.2 0.36 7.9979 0 184 150.2 7.6081 33.0534 63.0 1.3 0.020 4.370 33.0802 1.80 21.9 34.1 -99.00 -99.0000 0 183 201.0 7.1060 33.7036 63.5 1.3 -0.002 3.020 33.7102 2.19 29.2 43.3 -99.00 -99.0000 0 182 300.0 6.3200 33.9343 63.8 1.3 -0.002 2.270 33.9394 2.48 34.1 55.3 -99.00 7.6743 0 181 399.1 5.5140 33.9732 64.0 1.3 0.000 1.670 33.9743 2.73 37.6 68.0 -99.00 -99.0000 0 180 599.9 4.5366 34.1146 64.6 1.3 0.003 0.650 34.1173 3.08 42.7 94.0 -99.00 -99.0000 0 179 800.6 3.9268 34.2356 64.5 1.3 0.004 0.410 34.2374 3.20 44.2 114.4 -99.00 7.5111 0 178 1002.0 3.2813 34.3161 64.7 1.3 0.003 0.340 34.3181 3.21 44.9 133.5 -99.00 -99.0000 0 177 1251.1 2.9141 34.4204 64.5 1.3 0.004 0.390 34.4232 3.22 44.8 146.7 -99.00 -99.0000 0 176 1501.3 2.5024 34.4866 64.5 1.3 0.005 0.650 34.4855 3.17 44.9 159.3 -99.00 7.5582 0