*2013/12/16 15:19:17.99 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1999/07/03 06:03:17.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 375 382 2 Pressure decibar 1.3 99.3 3 Oxygen:Dissolved mL/L 1.945 6.748 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from Sea-Bird file: d:\data\1999\9928\99280065.ros Comments from secondary file: d:\data\1999\9928\99280065.oxy ------------------------------------------------------------ Raw data in file 992865 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = .01012771 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1999-28 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, GLOBEC SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : West Coast Vancouver Island STATION : LG03 EVENT NUMBER : 65 LATITUDE : 49 15.01000 N ! (deg min) LONGITUDE : 126 43.67000 W ! (deg min) WATER DEPTH : 126 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre SERIAL NUMBER : 0437 $TABLE: SENSORS ! Name Abs Depth Serial No ! ----------------- -------------- ---------- temperature ' ' primary conductivity ' ' primary pressure ' ' 63502 temperature ' ' secondary conductivity ' ' secondary fluorometer ' ' 'sea tech' transmissometer ' ' 182D irradiance ' ' 4495 WET ' ' 'WETStar fluorometer' $END $REMARKS SOFTWARE VERSION 4.235 Comments from secondary file: d:\data\1999\9928\99280065.oxy ------------------------------------------------------------ Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.1 1999/07/19 08:15:00 776 776 BINAVE 3.0 1999/07/21 10:07:55 776 8 MERGE 2.3 1999/07/22 08:59:02 8 8 REMOVECH 3.2 2000/01/11 16:17:13 8 8 HDREDIT2 1.9 2004/01/15 13:48:42 ? ? SORT 3.4.1 2004/01/15 13:50:56 8 8 CLEAN 4.5 2004/01/15 13:51:32 8 8 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:19:17 8 8 $END $REMARKS -The following BINAVE parameters were used: Bin channel = SAMPLE_NUMBER Averaging interval = 1.0 Minimum bin value = 0.000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Temperature:Secondar, Salinity:T0:C0, Salinity:T1:C1, Transmissivity, Irradiance_PAR, Chl_fluorescence, Bottle_Number Secondary Channels to Include: Dissolved_Oxygen:vol, Flask_Number Primary file : d:\data\1999\9928\99280065.avg Secondary file: d:\data\1999\9928\99280065.oxy Comments from secondary file: d:\data\1999\9928\99280065.oxy ------------------------------------------------------------ C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixes DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard had been entered. -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY TEMPERATURE:PRIMARY SALINITY:T0:C0 SALINITY:T1:C1 TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD IRRADIANCE_PAR CHL_FLUORESCENCE TRANSMISSIVITY BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD TEMPERATURE -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. $END *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 382 1.3 6.748 381 5.0 6.737 380 10.1 6.735 379 20.6 5.460 378 30.1 4.669 377 49.0 3.459 376 75.0 3.143 375 99.3 1.945