*2013/12/16 15:17:11.91 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1998/10/10 00:00:00.000 NUMBER OF RECORDS : 1 DATA DESCRIPTION : Loop FILE TYPE : ASCII NUMBER OF CHANNELS : 5 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------- --------- -------------- -------------- 1 Pressure decibar 5 5 2 Sample_Number n/a 279 279 3 Nitrate_plus_Nitrite umol/L 0 0 4 Silicate umol/L 4.2 4.2 5 Phosphate umol/L 0.35 0.35 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 5 I I 0 3 -99 ' ' 6 F ' ' 1 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 7 F ' ' 2 $END *ADMINISTRATION MISSION : 1998-36 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, GLOBEC SCIENTIST : Yelland D. PLATFORM : John P. Tully *LOCATION STATION : MP08 EVENT NUMBER : 75 LATITUDE : 48 53.27500 N ! (deg min) LONGITUDE : 128 40.26500 W ! (deg min) WATER DEPTH : 5 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 2.1 1999/05/07 12:12:18 0 1 REMOVECH 3.1 1999/05/07 13:26:11 1 1 HDREDIT2 1.8 2004/01/13 11:41:49 ? ? SORT 3.4.1 2004/01/13 11:47:17 1 1 CLEAN 4.5 2004/01/13 11:47:28 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:17:11 1 1 $END $REMARKS -The following CHANNEL(S) were removed from file. N1 N2 S1 S2 P1 P2 -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. $END *CALIBRATION *COMMENTS Sample taken from the seawater loop on the Tully. "Nutrients were measured using an Autoanalyzer II, following the " Procedures outlined in 'Institute of Ocean Sciences Nutrient Methods "and Analysis, Barwell-Clarke and Whitney, 1997'. The samples were" frozen on board and brought back to IOS for analysis by contract. Nitrate/silicate samples were defrosted for about 24 hours before analysis. Phosphate samples were rapidly defrosted in moving room temperature air "or warm water. Lab temperature was noted periodically, and may be found " on the original data sheets; it was generally around 26 C. Samples were inverted and shaken before analysis. "See file 9836nutr.xls for details on the analysis, turbidity corrections " and calibration for the nutrient data. "For nutrients, total of 130 samples were measured and of these, 18 samples" were measured in duplicate to estimate variability and the pooled standard deviations are as follows: Nitrate Sp=0.49 uM; Silicate Sp=0.77 uM; Phosphate Sp=0.051 uM. !--1--- -2-- --3-- --4-- --5--- !Pressu Samp Nitra Silic Phosph !re le_ te_ ate ate ! Numb plus_ ! er Nitri ! te !------ ---- ----- ----- ------ *END OF HEADER 5.0 279 0.0 4.2 0.35