*2004/04/14 08:32:44.57 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1998/09/16 18:17:27.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 22 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII NUMBER OF CHANNELS : 7 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ---------------------- -------- -------------- -------------- 1 Sample_Number n/a 302 323 2 Pressure dbars 1.7 1502.4 3 Salinity:Bottle PSS-78 32.491 34.5016 4 Phosphate umol/L 0.33 3.28 5 Nitrate_plus_Nitrite umol/L 0 45.4 6 Silicate umol/L 1.6 162.2 7 Oxygen:Dissolved mL/L 0.278 6.914 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 7 F ' ' 2 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 6 F ' ' 1 7 -99 ' ' 8 F ' ' 3 $END $REMARKS Comments from secondary file: e:\data\1998\9829\98290094.cor ------------------------------------------------------------ Raw data in file 98290094 VI03 = 10.01 ! Volume of iodate standard (cm**3) NI03 = .01012876 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = 0 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1998-29 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : Line P SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : Line P, N.E. Pacific Ocean STATION : MP12 EVENT NUMBER : 94 LATITUDE : 48 57.96000 N ! (deg min) LONGITUDE : 130 39.84000 W ! (deg min) WATER DEPTH : 3248 *COMMENTS Sample 305, oxygen sample end-point had low colorimeter value. Sample 308, oxygen sample poor end-point due to large air bubble on colorime Sample 315, oxygen sample end-point had low colorimeter value. Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- MERGE 1.0 1998/10/06 11:20:27 22 22 MERGE 2.3 2000/01/12 14:09:08 22 22 REMOVECH 3.2 2000/01/14 09:47:56 22 22 REMOVECH 4.0 2000/05/26 08:45:35 22 22 HDREDIT2 1.2 2001/12/24 11:49:18 ? ? HDREDIT2 1.6 2003/04/28 14:59:43 ? ? CLEAN 4.2 2003/04/28 16:24:58 22 22 SORT 3.4.1 2004/04/14 08:32:44 22 22 $END $REMARKS -The following MERGE parameters were used: Primary File Extension: cln Secondary File Extension: ios Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Sample_Number,Pressure,Temperature:Primary,Salinity:T0:C0,Salinity:T1:C1,Transm Secondary Channels to Include: Sample_Number,Phosphate,Nitrate,Silicate,Ammonium,Chlorophyll -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Pressure, Temperature:Primary, Salinity:T0:C0, Salinity:T1:C1, Transmissivity, Irradiance_PAR, Chl_fluorescence, Bottle_Number, Salinity:Bottle, Phosphate, Nitrate_plus_Nitrite, Silicate, Ammonium, Chlorophyll Secondary Channels to Include: Dissolved_Oxygen:vol Primary file : e:\data\1998\9829\98290094.hyn Secondary file: e:\data\1998\9829\98290094.cor Comments from secondary file: e:\data\1998\9829\98290094.cor ------------------------------------------------------------ C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixes DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard had been entered. OxyRedo fixes DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard had been entered. -The following CALIB parameters were used: Calibration type = C Pressure offset = 0.0 Calibration file = d:\data\1998\9829\9829oxy.cor -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY Temperature:Primary Salinity:T0:C0 Salinity:T1:C1 VOLTAGE:SEATECH TRANS_ATTENUATION_COEF FLUOROMETER:SEATECH FLUOROMETER:SEAPOINT FLUOROMETER_SEATECH FLUOROMETER_SEAPOINT TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD IRRADIANCE_PAR CHL_FLUORESCENCE Transmissivity Bottle_Number SALINITY:CTD TEMPERATURE:CTD Temperature -The following CHANNEL(S) were removed from file. Ammonium CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 1 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre $REMARKS Comments from secondary file: e:\data\1998\9829\98290094.cor ------------------------------------------------------------ Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END !-1-- --2--- ---3---- --4--- --5-- --6-- ---7--- !Samp Pressu Salinity Phosph Nitra Silic Oxygen: !le_ re :Bottle ate te_ ate Dissolv !Numb plus_ ed !er Nitri ! te !---- ------ -------- ------ ----- ----- ------- *END OF HEADER 323 1.7 32.4910 0.33 0.0 2.3 5.743 322 10.2 32.5018 0.34 0.0 2.1 5.733 321 25.6 32.5824 0.34 0.0 1.6 5.807 320 50.8 32.7464 0.41 0.0 3.2 6.914 319 75.2 32.7432 0.61 2.8 4.9 6.575 318 98.3 32.7785 0.86 7.3 8.0 6.298 317 125.4 33.0742 1.20 13.5 15.1 5.648 316 149.5 33.4928 1.50 19.4 22.6 4.919 315 198.5 33.8976 1.78 25.4 33.7 4.134 314 250.5 33.9492 2.06 28.9 45.0 3.440 313 303.9 33.9275 2.29 32.2 53.5 2.952 312 403.6 33.9323 2.71 38.2 71.3 1.975 311 503.6 34.0094 2.95 41.1 83.1 1.225 310 601.1 34.1383 3.15 43.5 97.4 0.592 309 649.8 34.1824 3.19 43.9 104.6 0.447 308 697.2 34.2118 3.21 44.9 110.4 0.403 307 748.4 34.2446 3.23 44.6 116.3 0.333 306 801.3 34.2851 3.26 44.7 119.6 0.303 305 899.9 34.3335 3.28 44.8 127.2 0.282 304 1000.5 34.3689 3.28 45.4 133.9 0.278 303 1201.3 34.4303 3.26 45.3 148.5 0.369 302 1502.4 34.5016 3.18 44.9 162.2 0.699